Pirtek Oil & Gas Pty Ltd

Site

Pirtek Oil & Gas Pty Ltd

Accreditation No.

19624

Site No.

22725

Date of Accreditation

05 Nov 2015

Address

8 Jessie Lee Street
Henderson, WA 6166
Australia

pirtek.com.au/service-and-supply/oil-and-gas

Contact

Mr Mark Tinley P: +61 (08) 94374359

Availability

Services conditionally available to external clients

Scope of Accreditation

Pirtek Oil & Gas Pty Ltd

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of mechanical performance of pressure equipment Hose and hose assemblies Leakage Not applicable

AS 1180.5-1999, Subclause 7.4;

ASTM D380, Section 17.5;

ISO 1402, Subclause 8.4;

ISO 6605, Subclause 5.7;

SAE J343, Section 4.7

Up to 5000 bar
Burst pressure Not applicable

AS 1180.5-1999, Subclause 7.3;

ASTM D380, Section 16.1;

ISO 1402, Subclause 8.3;

ISO 6605, Subclause 5.4;

SAE J343, Section 4.4

Up to 5000 bar
Length change Not applicable

AS 1180.5-1999, Subclause 7.2.2;

AS 2117-1991, Subclause 2.1;

ASTM D380, Section 17.1.1;

ISO 1402, Subclause 8.2.2;

ISO 6605, Subclause 5.3;

SAE J343, Section 4.3

Hydrostatic pressure Not applicable

API SPEC 7K;

AS 1180.5-1999, Subclause 7.1;

AS 1851, Table 8.4, Item 1.4;

AS/NZS 4233.1, Appendix E;

ASTM D380 Section 17.3;

ISO 1402, Subclause 8.1;

ISO 6605 Subclause 5.2;

SAE J343 Section 4.2

Up to 5000 bar
Conductivity; Electrical continuity; Electrical resistance Not applicable

AS 1180.13B-1987;

ISO 8031, Subclauses 5 and 6

Piping; Pressure fittings Hydrostatic pressure; Leakage Not applicable ASME B16.5, para. 8;
ASME B31.3, Chapter VI, para. 345
Up to 5000 bar

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.