National Association of Testing Authorities, Australia
Scope of Accreditation
Qantas Airways Limited - Qantas Calibration Services Melbourne
Site
Qantas Calibration Services Melbourne
Accreditation No.
15761
Site No.
16966
Date of Accreditation
01 Oct 2008
Address
Ground floor, Avionics building, Gate 23, Operations Road
Melbourne Airport, VIC 3045
Australia
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
| Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DC and low frequency electrical metrology - Electrical measurement and test equipment | Ammeters; Capacitance meters; Digital multimeters (DMM); Ohm meters; Voltmeters | AC current; AC voltage; Capacitance; DC current; DC voltage; Frequency; Resistance | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability ofDC voltage 18 µV/V or 4 µV whichever is greater from 0 V to 1000 V DC current 160 µA/A or 0.028 µA whichever is greater from 0 A to 1 mA 130 µA/A or 160 µA whichever is greater above 1 mA to 100 mA 200 µA/A above 100 mA to 1 A 700 µA/A above 1 A to 10 A AC voltage 360 µV/V or 40 µV whichever is greater from 1 mV to 1000 V at 10 Hz to 50 kHz 840 µV/V or 110 µV whichever is greater from 1 mV to 10 V at 50 kHz to 100 kHz 2.4 mV/V or 230 µV whichever is greater from 1 mV to 3 V at 100 kHz to 300 kHz 2.0 mV/V above 10 V to 100 V at 50 kHz to 100 kHz AC current 2 mA/A or 0.4 µA whichever is greater from 100 µA to 100 mA at 10 Hz to 5 kHz 4.2 mA/A or 0.8 µA whichever is greater from 100 µA to 100 mA at 5 kHz to 10 kHz 1.6 mA/A above 100 mA to 10 A at 45 Hz to 1 kHz 5.5 mA/A above 100 mA to 1 A at 1 kHz to 5 kHz 24 mA/A above 100 mA to 1 A at 5 kHz to 10 kHz Resistance 0.150 mΩ/ Ω +1.4 mΩ from 0 Ω to 10 Ω 0.051 mΩ/ Ω above 10 Ω to 100 Ω 0.032 mΩ/ Ω above 100 Ω to 100 kΩ 0.057 mΩ/ Ω above 100 kΩ to 1 MΩ 0.12 mΩ/ Ω % above 1 MΩ to 10 MΩ 0.43 mΩ/ Ω above 10 MΩ to 100 MΩ 1.4 % above 100 MΩ to 1 GΩ Capacitance 0.4% or 1.2nF whichever is greater from 0 to 10 µF 0.51% above 10 µF to 10 mF 0.65% above 10 mF to 100 mF Frequency 2.5 µHz/Hz from 10 Hz to 300 kHz | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Pressure metrology - Pressure and vacuum measuring equipment | Digital pressure gauges; Mechanical pressure gauges; Vacuum gauges | Gauge pressure | By pressure calibrator; Comparison with dead weight tester | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With calibration and measurement capability of - For Digital gauges0.015% of reading or 0.0038 kPa (whichever is greater) in the range from 0 kPa to 70 MPa For Mechanical gauges 0.02% of reading or 1.4 kPa (whichever is greater) in the range from 0 kPa to 70 MPa For Vacuum gauges 0.02 kPa in the range from -95 kPa to 0 kPa | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Temperature metrology - Temperature measuring equipment | Metallic resistance thermometers | Temperature | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of0.11 ºC form -40 ºC to 200 ºC | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Torque - Torque measuring and testing equipment | Torque indicators; Torque transducers; Torque wrenches | Torque | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With calibration and measurement capability of - For Torque wrenches 1.5% of reading in the range from 0.5 Nm to 813 Nm For Torque transducers and Torque Indicators 0.2% of reading in the range from 0.5 Nm to 813 Nm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Torque - Torque standards | Torque calibrating equipment | Torque | Gravimetric measurement with reference beam | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With calibration and measurement capability of - 0.2% of reading in the range from 0.5 Nm to 813 Nm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.