National Association of Testing Authorities, Australia
Scope of Accreditation
QGS Quality Geotechnical Services Pty Ltd
Scope of Accreditation
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of geotechnical and civil construction material - Aggregate properties | Aggregates | Particle size distribution | Fine particles in road materials |
RMS (NSW) Method T107;TfNSW T107; TfNSW TS 02795.03 |
|
Evaluation of geotechnical and civil construction material - Road pavement structural performance | Road pavements | Structural performance evaluation | Benkelman beam; Deflection monitoring |
RMS (NSW) Method T160, RMS (NSW) Method T199;TfNSW T199; TfNSW TS 02795.22,TfNSW TS 02795.55 |
|
Evaluation of geotechnical and civil construction material - Soil classification | Soils | Moisture content | Drying oven |
AS 1289.2.1.1, RMS (NSW) Method T120 TfNSW TS 02795.14 |
|
Liquid limit; Plastic limit; Plasticity index | Casagrande; Casagrande one point |
AS 1289.3.1.1, AS 1289.3.1.2, AS 1289.3.2.1, AS 1289.3.3.1, RMS(NSW) Method T108;TfNSW T108;TfNSW T105;,RMS(NSW) Method T109;TfNSW T109;TfNSW T105; TfNSW TS 02795.01,TfNSW TS 02795.04,TfNSW TS 02795.05 |
|||
Description, identification and classification | Not applicable |
AS 1726 Tables 9 and 10 (laboratory tests only) |
|||
Linear shrinkage | Not applicable |
AS 1289.3.4.1, RMS(NSW) Method T113;TfNSW T113; TfNSW TS 02795.08 |
|||
Sieve analysis | Not applicable |
AS 1289.3.6.1, RMS(NSW) Method T106;TfNSW T106; TfNSW TS 02795.02 |
|||
Evaluation of geotechnical and civil construction material - Soil compaction characteristics | Soils | Dry density/moisture content relationship | Modified compactive effort; Standard compactive effort |
AS 1289.5.1.1, AS 1289.5.2.1, RMS (NSW) Method T111, RMS (NSW) Method T130 TfNSW TS 02795.06,TfNSW TS 02796.01 |
|
Dry density/moisture content relationship | Three compaction point |
RMS (NSW) Method T162 TfNSW TS 02795.24 |
|||
Maximum dry density | Not applicable |
RMS (NSW) Method T164 TfNSW TS 02795.26 |
|||
Assignment of optimum moisture content/maximum dry density (OMC/MDD) | Not applicable | AS 1289.5.4.2 | |||
Minimum and maximum dry density | Not applicable |
AS 1289.5.5.1 |
|||
Evaluation of geotechnical and civil construction material - Soil dispersion | Soils | Dispersion | Emerson class |
AS 1289.3.8.1 |
|
Evaluation of geotechnical and civil construction material - Soil field density | Soils | Compaction control | Hilf | AS 1289.5.7.1 | |
Dry density ratio | Calculation | AS 1289.5.4.1 | |||
Relative compaction | Not applicable |
RMS (NSW) Method T166 TfNSW TS 02795.28 |
|||
Density index | Not applicable |
AS 1289.5.6.1 |
|||
Density - In-situ | Nuclear gauge; Sand pouring apparatus; Sand-cone |
AS 1289.5.3.1, AS 1289.5.8.1, RMS (NSW) Method T119, RMS (NSW) Method T173 TfNSW TS 02795.13,TfNSW TS 02795.36 |
|||
Evaluation of geotechnical and civil construction material - Soil in-situ penetration | Soils | Penetration in-situ | Dynamic cone; Perth sand penetrometer |
AS 1289.6.3.2, RMS (NSW) Method T161 AS 1289.6.3.3 TfNSW TS 02795.23 |
|
Evaluation of geotechnical and civil construction material - Soil laboratory bearing properties | Soils | Bearing ratio | Remoulded specimens |
AS 1289.6.1.1, RMS (NSW) Method T117 TfNSW TS 02795.11 |
|
Evaluation of geotechnical and civil construction material - Soil natural contaminants | Soils | Acidity | pH |
AS 1289.4.3.1 |
|
Evaluation of geotechnical and civil construction material - Soil pre-treatment | Soils | Soil pre-treatment | Not applicable |
AS 1289.1.1, RMS (NSW) Method T102;TfNSW T102;TfNSW T105;, RMS (NSW) Method T105 TfNSW TS 02794.02,TfNSW TS 02795.01 |
|
Soil pre-treatment | Accelerated weathering pre-treatment |
RMS (NSW) Method T103;TfNSW T103;TfNSW T105; TfNSW TS 02794.03,TfNSW TS 02795.01 |
|||
Evaluation of geotechnical and civil construction material - Soil reactivity | Soils | Reactivity | Shrink/swell |
AS 1289.7.1.1 |
|
Evaluation of geotechnical and civil construction material - Soil stabilisation | Soils | Compressive strength | Uniaxial unconfined |
RMS (NSW) Method T116, RMS (NSW) Method T131 TfNSW TS 02795.10,TfNSW TS 02796.02 |
|
Sample collection | Soils | Not applicable | Site selection - Random sampling; Site selection - Random stratified sampling |
AS 1289.1.4.1, AS 1289.1.4.2 |
|
Not applicable | Disturbed soil sampling from a stockpile; Disturbed soil sampling from a windrow; Disturbed soil sampling in-situ |
AS 1289.1.2.1 |
|||
Not applicable | Undisturbed soil sampling by open-drive sampler |
AS 1289.1.3.1 |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
21234
Site No.
24823
Print date