National Association of Testing Authorities, Australia
Scope of Accreditation
SA Police - Radio and Traffic Technical Support (184)
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Chemical metrology - Breath alcohol instruments | Breath alcohol instruments | Alcohol content | Direct measurement against a reference standard | Calibration of Evidential Breath Analysis devices to NMI R 126 Pattern Approval Specifications for evidential Breath Analysers | " | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of- 0.003 g/210L above 0.000 g/210L up to 0.100 g/210L | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Speed and velocity - Speed measuring devices | Doppler (radar) equipment | Speed | Direct measurement against a reference standard | Calibration of RADAR devices ("K" band only) to AS 2898 Part 2, Section 2.2, | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of- 1.0 km/h from 25 km/h to 250 km/h | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Laser equipment including LIDAR | Speed | Direct measurement against a reference standard | Calibration of LIDAR devices to AS 4691 part 2, Section 2.2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of- 1.0 km/h from 25 km/h to 300 km/h |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
14677
Site No.
14752
Print date
15 Jan 2025