National Association of Testing Authorities, Australia
Scope of Accreditation
Raytheon Australia Pty Ltd
Site
Raytheon Australia ASTE Calibration Lab
Accreditation No.
19238
Site No.
21842
Date of Accreditation
02 Apr 2014
Address
Raytheon Australia ASTE Project, 101 Southgate Ave
Cannon Hill, QLD 4170
Australia
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DC and low frequency electrical metrology - Electrical measurement and test equipment | Ammeters; Current clamps; Digital multimeters (DMM); Insulation resistance test equipment; Ohm meters; Voltmeters | AC current; AC voltage; DC current; DC voltage; Resistance | Direct measurement against a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of -AC Voltage 0.06% of Reading from 100 mV to 1 V and from 20 Hz to 10 kHz 0.16% of Reading from 100 mV to 1 V and from above 10 kHz to 50 kHz 0.42% of Reading from 100 mV to 1 V and from above 50 kHz to 100 kHz 0.06% of Reading from above 1 V to 10 V and from 20 Hz to 10 kHz 0.16% of Reading from above 1 V to 10 V and from above 10 kHz to 50 kHz 0.06% of Reading from above 10 V to 100 V and from 45 Hz to 10 kHz 0.35% of Reading from above 10 V to 100 V and from above 10 kHz to 50 kHz 0.06% of Reading from above 100 V to 1000 V and from 45 Hz to 10 kHz DC Voltage 0.02% of Reading + 0.006 mV from 0 V to 1000 V DC Current 0.03% of Reading + 0.04 μA from 0 μA to 100 mA 0.09% of Reading from above 100 mA to 10 A Clamp Meters 0.9% of Reading + 0.15 A from 20 A to 1000 A AC Current 0.3% of Reading + 0.0001 mA from 1 mA to 10 mA and from 20 Hz to 1 kHz 0.3% of Reading + 0.005 mA from 1 mA to 10 mA and from above 1 khz to 10 kHz 0.3% of Reading from above 10 mA to 100 mA and from 20 Hz to 1 kHz 0.45% of Reading from above 10 mA to 100 mA and from above 1 khz to 10 kHz 0.3% of Reading from above 100 mA to 1 A and from 20 Hz to 1 kHz 4.3% of Reading from above 100 mA to 1 A and from above 1 kHz to 10 kHz 0.3% of Reading from above 1 A to 10 A and from 45 Hz to 1 kHz 4.3% of Reading from above 1 A to 10 A and from above 1 kHz to 10 kHz Clamp Meters 1.2% of Reading + 0.5 A from 20 A to 100 A and from 45 Hz to 400 Hz 1.3% of Reading + 1 A from above 100 A to 1000 A and from 45 Hz to 400 Hz Resistance 0.02% of Reading + 0.03 Ω from 10 Ω to 1 MΩ 0.03% of Reading from above 1 MΩ to 10 MΩ 0.2% of Reading from above 10 MΩ to 100 MΩ 2.5% of Reading from above 100 MΩ to 500 MΩ Insulation Resistance (up to 1000 V) 0.02% of Reading + 0.03 Ω from 10 Ω to 1 MΩ 0.03% of Reading from above 1 MΩ to 10 MΩ 0.2% of Reading from above 10 MΩ to 100 MΩ 2.5% of Reading from above 100 MΩ to 500 MΩ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Pressure metrology - Pressure and vacuum measuring equipment | Mechanical pressure gauges | Gauge pressure | By pressure calibrator | MSA Test Method 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of- 0.16% of Reading or 0.35 kPa (whichever is greater) from 0 kPa to 69 MPa | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature metrology - Ancillary temperature measuring equipment | Digital voltmeters (DVM) and digital multimeters (DMM) | Volt to temperature conversion | Direct measurement by electrical input | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of -Thermocouple devices (measure mode): Type K thermocouple: 0.85 °C from -200 °C to 1300 °C | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Time and frequency metrology - Frequency, time and waveform measuring equipment | Frequency meters | Frequency | Measurement against reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of -0.02% of Reading + 0.004 Hz from 10 Hz to 500 kHz |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.