SGP Group Pty Ltd

Site

SGP Group Pty Ltd

Accreditation No.

20872

Site No.

25061

Date of Accreditation

27 Sep 2021

Address

Level 1, Suite 5, 91 Landsborough Avenue
Scarborough, QLD 4020
Australia

Contact

Mr Graeme Perry P: +61 0420991544

Availability

Services available to external clients

Scope of Accreditation

SGP Group Pty Ltd

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of air control equipment Biological safety cabinets Sound level Not applicable AS 1807 clause 4.7 For determining compliance with:
AS 2252.1 (2002)
AS 2252.2
Integrity of HEPA filter installations Cold DOP AS 1807.7 (2000) For determining compliance with:
AS 2252.1 (2002)
AS 2252.2
Ultraviolet intensity Not applicable

AS 1807 clause 4.10


For determining compliance with:
AS 2252.1 (2002)
AS 2252.2
Integrity of HEPA filter installations Cold DOP AS 1807 clause 4.4 For determining compliance with:
AS 2252.1 (2002)
AS 2252.2
Air barrier containment Cold DOP AS 1807 clause 4.9 For determining compliance with AS 2252.2
Air velocity and uniformity of air velocity Cold DOP AS 1807 clause 4.1 For determining compliance with AS 2252.2
Illuminance Not applicable AS 1807 clause 4.5 For determining compliance with:
AS 2252.1 (2002)
AS 2252.2
Inward air velocity Cold DOP AS 1807 clause 4.8 For determining compliance with AS 2252.1 (2002)
Work zone integrity Cold DOP AS 1807 clause 4.3 For determining compliance with AS 2252.2
Clean rooms Air flow Not applicable AS ISO 14644 Part 3 Method B.3
Integrity of HEPA filter installations Cold DOP AS ISO 14644 Part 3 Method B.7
Sound level Not applicable AS 1807.16 (2000)
Clean rooms; Clean workstations Relative humidity (RH) Not applicable AS ISO 14644 Part 3 Method B.6
Air pressure Not applicable AS 1807.10 (2000)
AS ISO 14644 Part 3 Method B.1
Particle count in work zone Automatic particle counter AS ISO 14644 Part 1 Appendix A
Temperature Not applicable AS ISO 14644 Part 3 Method B.5
Air velocity and uniformity of air velocity Not applicable AS ISO 14644 Part 3 Method B.2
Clean workstations Illuminance Not applicable AS 1807 clause 4.5 For determining compliance with AS 2252.6
Ultraviolet intensity Not applicable AS 1807 clause 4.10 For determining compliance with AS 2252.6
Work zone integrity Cold DOP AS 1807 clause 4.3 For determining compliance with AS 2252.6
Sound level Not applicable AS 1807 clause 4.7 For determining compliance with AS 2252.6
Integrity of HEPA filter installations Cold DOP AS 1807.7 (2000),
AS 1807 clause 4.4
For determining compliance with AS 2252.6
Air velocity and uniformity of air velocity Cold DOP AS 1807 clause 4.1 For determining compliance with AS 2252.6
Cytotoxic drug safety cabinets Particle count in work zone Automatic particle counter AS ISO 14644 Part 1 Appendix A For determining compliance with AS 2252.5
Illuminance Not applicable AS 1807 clause 4.5 For determining compliance with AS 2252.5
Sound level Not applicable AS 1807 clause 4.7 For determining compliance with AS 2252.5
Integrity of HEPA filter installations Cold DOP AS 1807.7 (2000) For determining compliance with AS 2252.5
Air velocity and uniformity of air velocity Cold DOP AS 1807 clause 4.1 For determining compliance with AS 2252.5
Ultraviolet intensity Not applicable AS 1807 clause 4.10 For determining compliance with AS 2252.5
Air barrier containment Cold DOP AS 1807 clause 4.9 For determining compliance with AS 2252.5
Work zone integrity Cold DOP AS 1807 clause 4.3 For determining compliance with AS 2252.5
Fume cupboards and recirculating fume cabinets Sound level Not applicable AS 1807 clause 4.7 For determining compliance with:
AS/NZS 2243.8
AS/NZS 2243.9
Extraction performance Smoke visualisation AS/NZS 2243.8 Appendix A
AS/NZS 2243.9 Appendix A
Extraction performance Face velocity AS/NZS 2243.8 section Appendix B
AS/NZS 2243.9 section Appendix B
Illuminance Not applicable AS 1807 clause 4.5 For determining compliance with:
AS/NZS 2243.8
AS/NZS 2243.9
Pharmaceutical isolators Air velocity and uniformity of air velocity Cold DOP AS 1807 clause 4.1 For determining compliance with AS 4273
Particle count in work zone Automatic particle counter AS ISO 14644 Part 1 Appendix A For determining compliance with AS 4273
Air pressure Not applicable AS 1807.10 (2000)
AS ISO 14644 Part 3 Method B.1
For determining compliance with AS 4273
Integrity of HEPA filter installations Cold DOP AS 1807 clause 4.4 For determining compliance with AS 4273

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.