National Association of Testing Authorities, Australia
Scope of Accreditation
EMC Technologies Pty Ltd
Site
Sydney Laboratory – EMC Test Laboratory
Accreditation No.
5292
Site No.
10854
Date of Accreditation
14 Aug 1995
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
In-house Calibration
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DC and low frequency electrical metrology - Electrical measurement and test equipment | Insulation resistance test equipment | AC current; AC voltage; DC current; DC voltage; Resistance | Direct measurement against a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of -Earth Leakage Meter Type II 4.6% of reading in the range 0 to 10 mA Earth Leakage meter type MD 4.2% of reading in the range 0 to 20 V Electric Strength Tester 1.3 % of reading in the range 5 kV Resistor Box 1.2% of reading in the range 500 Ω to 10 MΩ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DC and low frequency electrical metrology - High-voltage/high-current standards and equipment | Impulse voltage measurement systems | Impulse voltage measurements | Indirect measurement against a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of -Impulse Test Generator 4.0% of reading in the range 0 to 10kV Impulse tester 7.5% of reading in the range ± 7 kV and 1.3 μs for Time and 9% of reading for Current |
ISO/IEC 17025 (2017)
Manufactured Goods
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Electrical equipment approval and safety evaluation | Audio, video and similar electronic equipment | Electrical safety | Dimensional assessment including creepage and clearance; Electrical characteristics; Endurance and resistance to external conditions; Energy measurement; Fire hazard assessment; Firmware assessment; Function assessment including abnormal operation; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination | AS/NZS 62368.1, IEC 62368-1 and EN 62368-1 excluding clause nos. 8.5.5, 10, G.5.2, G.15, M.8, S.5 and Annexes C, J, R and U | |
Electrical appliances, coupling devices and accessories | Electrical safety | Dimensional assessment including creepage and clearance; Electrical characteristics; Endurance and resistance to external conditions; Energy measurement; Fire hazard assessment; Firmware assessment; Function assessment including abnormal operation; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination | AS/NZS 60695.2.11 AS/NZS 60695.10.2 AS/NZS 60695.11.5 | ||
Electrical safety | Dimensional assessment including creepage and clearance; Electrical characteristics; Endurance and resistance to external conditions; Energy measurement; Fire hazard assessment; Firmware assessment; Function assessment including abnormal operation; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination | AS/NZS 60335.1 IEC 60335-1 EN 60335.1 (excluding Annex N) , IP testing for IPX4 is limited to items that | |||
Electrical machines and auxiliary apparatus; Electrical plugs, sockets, lead assemblies and related components; Lamps and lampholders (including LED-based lamps); Power adapters, low voltage power supply components, appliance transformers, power stabilisers and related items; Power tools - Electric | Electrical safety | Dimensional assessment including creepage and clearance; Electrical characteristics; Endurance and resistance to external conditions; Energy measurement; Fire hazard assessment; Firmware assessment; Function assessment including abnormal operation; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination | AS/NZS 3100 AS/NZS 3136 | ||
Enclosures for electrical equipment | Degree of protection - IP rating | Not applicable | AS 60529 IEC 60529 | excluding IP5X, IP6X and IPX9 IP testing for IPX4 is limited to items that fit within a rotating tube with maximum radius of 400 mm | |
Information technology equipment | Electrical safety | Dimensional assessment including creepage and clearance; Electrical characteristics; Endurance and resistance to external conditions; Energy measurement; Fire hazard assessment; Firmware assessment; Function assessment including abnormal operation; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination | AS/NZS 62368.1, IEC 62368-1 and EN 62368-1 excluding clause nos. 8.5.5, 10, G.5.2, G.15, M.8, S.5 and Annexes C, J, R and U | ||
Laboratory and electromedical equipment | Electrical safety | Dimensional assessment including creepage and clearance; Electrical characteristics; Endurance and resistance to external conditions; Energy measurement; Fire hazard assessment; Firmware assessment; Function assessment including abnormal operation; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination | AS 61010.1, IEC 61010-1 EN 61010-1; IEC 61010-2-10 and EN 61010-2-10; IEC 61010-2-20 and EN 61010-2-20; IEC 61010-2-30 and EN 61010-2-30; IEC 61010-2-40 and EN 61010-2-40; IEC 61010-2-51 and EN 61010-2-51; IEC 61010-2-81 and EN 61010-2-81; IEC 61010-2-101 and EN 61010-2-101; IEC 61010-2-201 and EN 61010-2-201; AS/NZS 60601.1, IEC 60601-1, EN 60601-1 | excluding clause 12 (other than 12.4 up to 45 GHz) and clause 13.2.3 (implosion of CRT tubes) of AS 61010.1,.IEC 61010-1 and EN 61010-1; and excluding defibrillation test to AS/NZS 60601.1, IEC 60601-1 and EN 60601-1 | |
Power adapters, low voltage power supply components, appliance transformers, power stabilisers and related items | Electrical safety | Dimensional assessment including creepage and clearance; Electrical characteristics; Endurance and resistance to external conditions; Energy measurement; Fire hazard assessment; Firmware assessment; Function assessment including abnormal operation; Insulation and electrical protection measurement; Mechanical assessment; Temperature; Visual examination | AS/NZS 61558.1, IEC 61558-1, EN 61558-1 AS/NZS 61558.2.6, IEC 61558-2-6, EN 61558-2-6 AS/NZS 61558.2.16, IEC 61558-2-16, EN 61558-2-16 | ||
Electromagnetic compatibility (EMC) - Emissions - Commercial | Airborne equipment | Conducted emissions; Radiated emissions | Not applicable | RTCA DO160 F/G section 21 | Conducted RF emissions 150 kHz to 150 MHz |
Electrical and electronic products; Multimedia equipment; Power tools - Electric | Conducted emissions; Discontinuous disturbances; Disturbance power; Radiated emissions | Not applicable | AS/NZS CISPR 14.1; CISPR 14-1; EN 55014-1; CNS 13783-1; | Reference to Radiated measurements performed in the 3 metre iOATS Semi Anechoic Chamber Room 3. FCC Part 15 requirements and ANSI C63.4:2014, ANSI C63.10:2013, KDB Publications, and ISED (formerly Industry Canada) For unintentional and intentional emitters in the frequency range 9 kHz to 40 GHz -Unintentional Radiators described in FCC Part 15, Subpart B using ANSI C63.4-2014 ; -Intentional Radiators described in FCC Part 15, Subpart C using ANSI C63.10-2013 ; -Intentional Radiators described in FCC Part 15, Subpart E for U-NII devices without DFS, using ANSI C63.10:2013; KDB 789033 D02 General U-NII test procedure - new rules; KDB 558074 D01 DTS measurement guidance. ICES-003; RSS-247; RSS-210; RSS-GEN | |
Electrical equipment for measurement, control and laboratory use | Conducted emissions; Radiated emissions | Not applicable | AS/NZS 2064; AS/NZS CISPR 11; CISPR 11; EN 55011; CNS 13803; | Excluding measurements below 2 kHz | |
Electrical lighting and similar equipment | Conducted emissions; Radiated emissions | Not applicable | AS/NZS CISPR 15; CISPR 15; EN 55015 | ||
Information technology equipment | Conducted emissions; Conducted telecommunications port emissions; Radiated emissions; Radio influence voltage measurement | AMN and voltage probe; ISN and current clamp | AS/NZS CISPR 22; CISPR 22; CAN/CSA-CEI/IEC CISPR 22; VCCI; CNS 13438; EN 55022 | Reference to Radiated measurements performed in the 3 metre iOATS Semi Anechoic Chamber Room 3. Excluding capacitive voltage probe tests for telecommunications ports | |
Machine tools | Conducted emissions; Discontinuous disturbances; Mains harmonics and flicker; Radiated emissions | Not applicable | AS/NZS 2064; AS/NZS CISPR 11; CISPR 11; EN 55011; CNS 13803; | ||
Maritime navigation equipment | Conducted emissions; Radiated emissions | Not applicable | EN 60945 | Excluding measurements below 2 kHz | |
Medical electrical equipment | Radiated emissions | Not applicable | AS/NZS 2064; AS/NZS CISPR 11; CISPR 11; EN 55011; CNS 13803; | ||
Radio equipment | Conducted emissions; Radiated emissions | Not applicable | ETSI EN 301 489-1 | ||
Railway vehicles and equipment including railway signalling and telecommunications equipment | Conducted emissions; Radiated emissions | Not applicable | EN 50121-3-1; EN 50121-3-2; EN 50121-4; | ||
Sound and television broadcast receivers and associated equipment | Conducted emissions; Radiated emissions | Not applicable | AS/NZS CISPR 13; CISPR 13; EN 55013; CNS 13439 | ||
Telecommunication network equipment | Conducted emissions; Radiated emissions | Not applicable | ETSI EN 300 386 | ||
Vehicles, boats and internal combustion engine driven equipment | Conducted emissions; Radiated emissions | Not applicable | AS/NZS CISPR 12; CISPR 12; EN 55012; | Testing on components only | |
Electromagnetic compatibility (EMC) - Emissions - Military | Aerospace and military grade equipment | Conducted emissions | Not applicable | MIL-STD-461 B/C: CE01 - 0 to 15 kHz; | |
Radiated emissions | Not applicable | MIL-STD-461 B/C: RE01; MIL-STD-461 B/C: RE02; MIL-STD-461 D/E/F/G: RE101; MIL-STD-461 D/E/F/G: RE102; | MIL-STD-461 B/C: RE01 - 30 Hz to 50 kHz MIL-STD-461 B/C: RE02 - 14 kHz to 10 GHz MIL-STD-461 D/E/F/G: RE101 - 30 Hz to 100 kHz MIL-STD-461 D/E/F/G: RE102 - 10 kHz to 18 GHz | ||
Power leads | Conducted emissions | Not applicable | MIL-STD-461 D/E/F/G: CE101 (30 Hz to 10 kHz); | ||
Electromagnetic compatibility (EMC) - Immunity - Commercial | Airborne equipment | Conducted disturbance; Conducted susceptibility; Electrostatic discharge; Induced signal susceptibility; Magnetic effects; Radiated radio-frequency; Radiated susceptibility; Voltage spikes | Not applicable | RTCA DO160 F/G Sections 15, 17, 18, 19, 20, 25; | |
Components of fire, intruder and social alarm systems | Conducted disturbance; Conducted susceptibility; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Radiated susceptibility; Surge immunity; Voltage short dips and interruptions | Not applicable | EN 50130-4; | ||
Electrical and electronic products; Power tools - Electric | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable | AS/NZS CISPR 14.2; CISPR 14-2; EN 55014-2; | ||
Electrical equipment for measurement, control and laboratory use | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable | IEC 61326-1; EN 61326-1; | ||
Electrical lighting and similar equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable | EN 61547; ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2 IEC 801-3; AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 60255-22-3; ISO 11452-2; IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4; AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5; AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6; AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8; IEC 61000-4-9; EN 61000-4-9; IEC 61000-4-10; EN 61000-4-10; AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11 IEC 61000-4-12; AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16; IEC 61000-4-18; EN 61000-4-18 | ||
Electricity meters and associated transformers | Electrical fast transient; Radiated radio-frequency; Surge immunity | Not applicable | NSC publication for Pattern Approval and Initial verification of electricity meters and associated transformers | ||
Gaming machines | Electrical fast transient; Electrostatic interference; Voltage short dips and interruptions | Not applicable | Australian/New Zealand Gaming Machine National Standard clauses 6.28 to 6.32 only | ||
Information technology equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable | AS/NZS CISPR 24; CISPR 24; EN 55024; | ||
Low voltage switchgear and control equipment | Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable | EN 60947; | ||
Machine tools | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable | AS/NZS 61000.6.2; IEC 61000-6-2; EN 61000-6-2; ESD - IEC 801-2; AS/NZS 61000.4.2; IEC 61000-4-2; EN 61000-4-2; IEC 255-22-2 IEC 801-3; AS/NZS 61000.4.3; IEC 61000-4-3; EN 61000-4-3; IEC 801-4; AS/NZS 61000.4.4; IEC 61000-4-4; EN 61000-4-4; IEC 60255-22-4; AS/NZS 61000.4.5; IEC 61000-4-5; EN 61000-4-5; IEC 255-5; AS/NZS 61000.4.6; IEC 61000-4-6; EN 61000-4-6; AS/NZS 61000.4.8; IEC 61000-4-8; EN 61000-4-8; IEC 61000-4-9; EN 61000-4-9; IEC 61000-4-10; EN 61000-4-10; AS/NZS 61000.4.11; IEC 61000-4-11; EN 61000-4-11 IEC 61000-4-12; AS/NZS 61000.4.13; IEC 61000-4-13; EN 61000-4-13; AS/NZS 61000.4.16; IEC 61000-4-16; EN 61000-4-16; IEC 61000-4-18; EN 61000-4-18 | ||
Medical electrical equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable | AS IEC 60601.1.2, IEC 60601-1-2; EN 60601-1-2; | ||
Multimedia equipment | Common mode low frequency; Conducted disturbance; Conducted susceptibility; DC input power ripple; Damped oscillatory wave; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Induced signal susceptibility; Magnetic effects; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Radiated susceptibility; Ring wave; Surge immunity; Voltage fluctuations; Voltage short dips and interruptions; Voltage spikes | Not applicable | EN 55035 excluding clause 4.2.7; AS/NZS CISPR 35 excluding clause 4.2.7; CISPR 35 excluding clause 4.2.7 | ||
Radio equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable | ETSI EN 301 489-1; | ||
Railway vehicles and equipment including railway signalling and telecommunications equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable | EN 50121-3-2; EN 50121-4; EN 51021-5; | ||
Telecommunication network equipment | Conducted disturbance; Electrical fast transient; Electrostatic discharge; Harmonic and inter harmonics low frequency; Power frequency magnetic field; Pulsed magnetic field; Radiated radio-frequency; Surge immunity; Voltage short dips and interruptions | Not applicable | ETSI EN 300 386; | ||
Electromagnetic compatibility (EMC) - Immunity - Military | Aerospace and military grade equipment | Conducted susceptibility; Radiated susceptibility | Bulk cable injection; Damped sinusoidal transients; Impulse excitation; Magnetic field | MIL-STD-461 D/E/F/G: RS101, RS103 | MIL-STD-461 D/E/F/G RS101: 30 Hz to 100 kHz; MIL-STD-461 D/E/F/G RS103: 2 MHz to 18 GHz; MIL-STD-461 D/E/F/G CS101: 30 Hz to 150 kHz; MIL-STD-461 D/E/F/G CS114: 10 kHz to 400 MHz; |
Electromagnetic radiation exposure - Extremely low frequency (ELF) fields | Electricity grid installations; High voltage transformer equipment; Residential, commercial and light industrial environments | Broadband measurements of H-fields; Narrowband measurements of H-fields | Not applicable | ARPANSA Radiation Protection Standard (RPS S-1); AS/NZS 2772.2 and NZS 2772.1; | |
Electromagnetic radiation exposure - Radiofrequency (RF) fields | Antennas; Microwave ovens; Rolling stock | Broadband measurements of E-fields; Broadband measurements of H-fields; Measurement of electromagnetic fields; Narrowband measurements of E-fields; Narrowband measurements of H-fields | Not applicable | ARPANSA Radiation Protection Standard (RPS S-1); AS/NZS 2772.2 and NZS 2772.1; | Broadband measurements of E-fields in the range 9 kHz to 60 GHz ; |
Shielded enclosures | Attenuation performance | Not applicable | MIL-STD-285 Rev. 1.8 | ||
Evaluation of electrical appliances and devices - Performance | External power supplies, stabilisers and related items | Capacitance; Capacity; Current; Electrical energy consumption; Electrical parameters; Power, voltage, current and impulse protection performance; Stability | Not applicable | AS/NZS 4665.1 |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
5292
Site No.
10854
Print date