Territory Instruments

Site

Territory Instruments

Accreditation No.

20424

Site No.

24452

Date of Accreditation

27 Apr 2021

Address

15 Raphael Road
Winnellie, NT 820
Australia

territoryinstruments.com

Contact

Mr Stuart Kenny P: +61 (08) 89475450

Availability

Services available to external clients

Scope of Accreditation

Territory Instruments

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
DC and low frequency electrical metrology - Electrical instrument calibrators Instrument calibrators DC current; DC voltage; Resistance Comparison with a reference standard; Direct measurement Industrial process calibrators only





Capability

With Calibration and Measurement Capability of -

DC Voltage
0.04% from 1mV to 100mV
0.02% above 100 mV up to 1000 V

DC Current
0.09% + 1 µA above 100uA to 1mA
0.2% above 1mA to 1A
0.4% above 1A to 10A

Resistance
0.05% from 10 Ω to 10 MΩ
0.65% above 10 MΩ to 100 MΩ


DC and low frequency electrical metrology - Electrical measurement and test equipment Ammeters; Digital multimeters (DMM); Insulation resistance test equipment; Ohm meters; Voltmeters AC current; AC voltage; DC current; DC voltage; Resistance Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -

DC Voltage
0.24% from 2 mV up to 20 mV
0.03% above 20 mV up to 200 mV
0.01% above 200 mV up to 20 V
0.02% above 20 V up to 1000 V

AC Voltage
from 3 mV to 33 mV
0.75% from 45 Hz to 100 kHz
1% above 100 kHz to 450k Hz

above 33 mV to 330 mV
0.06% from 45 Hz to 20 kHz
0.09% above 20 kHz to 50 kHz
0.52% above 50 kHz to 500 kHz

above 330 mV to 33 V
0.09% from 45 Hz to 50 kHz
0.47% above 50k Hz to 50 0kHz

above 33 V to 330 V
0.1% from 45 Hz to 50 kHz
0.25% above 50 kHz to 100 kHz

above 330 V to 1020 V
0.08% from 45 Hz to 8 kHz

DC Current
0.01% +0.2 µA from 0 to 330 μA
0.09% +0.2 µA above 330 μA to 20.5 A

AC Current
from 33 μA to 330 μA
0.7% from 10 Hz to 10k Hz

above 330 μA to 3.3 mA
1% + 4μA from 10 Hz to 45 Hz
0.4% above 45 Hz to 10 kHz

above 3.3mA to 33mA
1% + 4μA from 10 Hz to 45 Hz
0.08% above 45 Hz to 10 kHz
0.17% above 5 kHz to 10 kHz

above 33 mA to 330 mA
0.17% from 10 Hz to 20 Hz
0.09% above 20 Hz to 5 kHz
0.18% above 5 kHz to 10 kHz

above 330mA to 1.1A
0.2% from 10 Hz to 45 Hz
0.06% above 45 Hz to 1 kHz
0.6% above 1 kHz to 5 kHz
2.3% above 5 kHz to 10 kHz

above 1.1A to 3 A
0.85% from 10 Hz to 45 Hz
0.16% above 45 Hz to 1 kHz
0.06% above 1 kHz to 5 kHz
0.5% above 5 kHz to 10 kHz

above 3A to 11A
0.6% from 10Hz to 45Hz
0.09% above 45Hz to 1kHz
0.18% above 1kHz to 5kHz

above 11A to 20.5A
1.5% from 10 Hz to 45 Hz
0.12% above 45 Hz to 1 kHz
0.2% from 1 kHz to 5 kHz

Resistance
0.6% from 2 Ω to 33 Ω
0.04% above 33 Ω to 110 Ω
0.02% above 110 Ω to 1.10 MΩ
0.03% above 1.10 MΩ to 3.3 MΩ
0.06% above 3.3 MΩ to 11 MΩ
0.09% above 11 MΩ to 119 MΩ  

Insulation Resistance
0.7%  above 100 kΩ to 999.9 MΩ from 50 V to 5 kV
2.5%  above 999.9 MΩ to 10 GΩ from 50 V to 5 kV




Pressure metrology - Pressure and vacuum measuring equipment Digital pressure gauges; Mechanical pressure gauges; Pressure recorders; Pressure transducers; Vacuum gauges Gauge pressure Comparison with reference instrument MSA test methods 1 and 2

Capability

with Calibration and Measurement Capability of -
0.04 % of reading  or  40 Pa (whichever is greater) from -95 kPa to 100 kPa
0.04 % of reading above 100 kPa to 1 MPa
0.03% of reading above 1 MPa to 21 MPa
Pressure metrology - Pressure standards Pressure calibrators - Non-dead weight Gauge pressure Comparison with dead weight tester MSA Test method 1

Capability

with Calibration and Measurement Capability of -
0.04 % of reading or 40 Pa (whichever is greater) from -95 kPa to 100 kPa
0.04 % of reading above 100 kPa to 1 MPa
0.03% of reading above 1 MPa to 21 MPa
Torque - Torque measuring and testing equipment Torque wrenches Torque Comparison with a reference standard ISO 6789-2

Capability

with Calibration and Measurement Capability of -
0.9 % of reading from 15 Nm to 1000 Nm