TR Pty Ltd (Trading as TechRentals Calibration & Sales)

TechRentals Calibration & Sales

Site

TR Calibration Brisbane Facility

Accreditation No.

116

Site No.

11509

Date of Accreditation

30 May 1996

Address

72 Donaldson Road
Rocklea, QLD 4106
Australia

trcalibration.com.au

Contact

Mr Kerri Kirk P: +61 (07) 37179100

Availability

Services available to external clients

Scope of Accreditation

TR Calibration Brisbane Facility

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
DC and low frequency electrical metrology - Electrical instrument calibrators Instrument calibrators DC current Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -

25 μA/A + 0.9 nA from 10 μA to 100 μA
25 μA/A + 6 nA above 100 μA to 1 mA
25 μA/A + 60 nA above 1 mA to 10 mA
45 μA/A + 0.6 μA above 10 mA to 100 mA
0.01% above 100 mA to 1 A
0.02% above 1 A to 2 A
0.05% above 2 A to 10 A
0.12% above 10 A to 20 A 

AC voltage Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -

0.07% from 10 mV to 22 mV and from 10 Hz to 20 kHz
0.08% from 10 mV to 22 mV and from 20 kHz to 50 kHz
0.24% from 10 mV to 22 mV and from 50 kHz to 100 kHz
0.35% from 10 mV to 22 mV and from 100 kHz to 300 kHz
0.05% from 22 mV to 220 mV and from 10 Hz to 50 kHz
0.1% from 22 mV to 220 mV and from 50 kHz to 100 kHz
0.34% from 22 mV to 220 mV and from 100 kHz to 300 kHz
0.05% from 0.22 V to 2.2 V and from 10 Hz to 50 kHz
0.1% from 0.22 V to 2.2 V and from 50 kHz to 100 kHz
0.16% from 0.22 V to 2.2 V and from 100 kHz to 300 kHz
0.05% from 2.2 V to 22 V and from 10 Hz to 50 kHz
0.1% from 2.2 V to 22 V and from 50 kHz to 100 kHz
0.22% from 2.2 V to 22 V and from 100 kHz to 300 kHz
0.03% from 22 V to 220 V and from 10 Hz to 20 kHz

0.15% from 22 V to 70 V and from 100 kHz to 300 kHz
0.08% from 22 V to 220 V and from 20 kHz to 50 kHz
0.3% from 22 V to 220 V and from 50 kHz to 100 kHz
0.02% from 220 V to 1000 V and from 15 Hz to 40 Hz
0.03% from 220 V to 1100 V and from 40 Hz to 20 kHz
0.08% from 220 V to 750 V and from 20 kHz to 50 kHz 

DC voltage Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -

0.002% + 0.2 μV from 0.01 V up to 0.22 V
0.001% + 0.2 μV from above 0.22 V up to 2.2 V
0.001% + 1.3 μV from above 2.2 V up to 11 V
0.003% + 3 μV from above 11 V up to 22 V
0.005% + 33 μV from above 22 V up to 220 V
0.002% + 164 μV from above 220 V up to 1100 V 

Resistance Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -
0.13% from 500 μΩ to less than 1 Ω
0.01% from 1 Ω to 5 Ω
0.005% above 5 Ω to 10 Ω
0.003% above 10 Ω to 1 MΩ
0.01% above 1 MΩ to 10 MΩ
0.07% above 10 MΩ to 1 GΩ

AC current Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -

 0.07% from 100 μA to 220 μA from 10 Hz to 1 kHz
0.11% from 100 μA to 220 μA from 1 kHz to 5 kHz
0.54% from 100 μA to 220 μA from 5 kHz to 10 kHz
0.07% above 220 μA up to 2.2 mA from 10 Hz to 1 kHz
0.19% above 220 μA up to 2.2 mA from 1 kHz to 5 kHz
0.65% above 220 μA up to 2.2 mA from 5 kHz to 10 kHz
0.07% above 2.2 mA up to 22 mA from 10 Hz to 1 kHz
0.19% above 2.2 mA up to 22 mA from 1 kHz to 5 kHz
0.56% above 2.2 mA up to 22 mA from 5 kHz to 10 kHz
0.08% above 22 mA up to 220 mA from 10 Hz to 1 kHz
0.2% above 22 mA up to 220 mA from 1 kHz to 5 kHz
1.1% above 22 mA up to 220 mA from 5 kHz to 10 kHz
0.05% above 220 mA up to 2.2 A from 10 Hz to 40 Hz
0.07% above 220 mA up to 2.2 A from 40 Hz to 1 kHz
0.9% above 220 mA up to 2.2 A from 1 kHz to 5 kHz
0.12% above 2.2 A up to 10 A from 40 Hz to 1 kHz
0.43% above 2.2 A up to 10 A from 1 kHz to 10 kHz
0.21% above 10 A up to 20 A from 40 Hz to 1 kHz
3.5% above 10 A up to 20 A from 1 kHz to 5 kHz 

DC and low frequency electrical metrology - Electrical measurement and test equipment Ammeters; Appliance testers; Digital multimeters (DMM); Residual current devices (RCD) testers DC current Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -

25 μA/A + 0.9 nA from 10 μA to 100 μA
25 μA/A + 6 nA above 100 μA to 1 mA
25 μA/A + 60 nA above 1 mA to 10 mA
45 μA/A + 0.6 μA above 10 mA to 100 mA
0.01% above 100 mA to 1 A
0.02% above 1 A to 2 A
0.05% above 2 A to 10 A
0.12% above 10 A to 20 A

AC current Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -

0.07% from 100 μA to 220 μA and from 10 Hz to 1 kHz
0.11% from 100 μA to 220 μA and from 1 kHz to 5 kHz
0.54% from 100 μA to 220 μA and from 5 kHz to 10 kHz
0.07% above 220 μA to 2.2 mA and from 10 Hz to 1 kHz
0.19% above 220 μA to 2.2 mA and from 1 kHz to 5 kHz
0.65% above 220 μA to 2.2 mA and from 5 kHz to 10 kHz
0.07% above 2.2 mA to 22 mA and from 10 Hz to 1 kHz
0.19% above 2.2 mA to 22 mA and from 1 kHz to 5 kHz
0.56% above 2.2 mA to 22 mA and from 5 kHz to 10 kHz
0.08% above 22 mA to 220 mA and from 10 Hz to 1 kHz
0.2% above 22 mA to 220 mA and from 1 kHz to 5 kHz
1.1% above 22 mA to 220 mA and from 5 kHz to 10 kHz
0.05% above 220 mA to 2.2 A and from 10 Hz to 40 Hz
0.07% above 220 mA to 2.2 A and from 40 Hz to 1 kHz
0.9% above 220 mA to 2.2 A and from 1 kHz to 5 kHz
0.12% above 2.2 A to 10 A and from 40 Hz to 1 kHz
0.43% above 2.2 A to 10 A and from 1 kHz to 10 kHz
0.21% above 10 A to 20 A and from 40 Hz to 1 kHz
3.5% above 10 A to 20 A and from 1 kHz to 5 kHz

Appliance testers; Digital multimeters (DMM); Residual current devices (RCD) testers; Voltmeters AC voltage Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -

0.07% from 10 mV to 22 mV and from 10 Hz to 20 kHz
0.08% from 10 mV to 22 mV and from 20 kHz to 50 kHz
0.24% from 10 mV to 22 mV and from 50 kHz to 100 kHz
0.35% from 10 mV to 22 mV and from 100 kHz to 300 kHz
0.05% above 22 mV to 220 mV and from 10 Hz to 50 kHz
0.1% above 22 mV to 220 mV and from 50 kHz to 100 kHz
0.34% above 22 mV to 220 mV and from 100 kHz to 300 kHz
0.05% above 0.22 V to 2.2 V and from 10 Hz to 50 kHz
0.1% above 0.22 V to 2.2 V and from 50 kHz to 100 kHz
0.16% above 0.22 V to 2.2 V and from 100 kHz to 300 kHz
0.05% above 2.2 V to 22 V and from 10 Hz to 50 kHz
0.1% above 2.2 V to 22 V and from 50 kHz to 100 kHz
0.22% above 2.2 V to 22 V and from 100 kHz to 300 kHz

0.15% above 22 V to 70 V and from 100 kHz to 300 kHz
0.03% above 22 V to 220 V and from 10 Hz to 40 Hz
0.03% above 22 V to 220 V and from 40 Hz to 20 kHz
0.08% above 22 V to 220 V and from 20 kHz to 50 kHz
0.3% above 22 V to 220 V and from 50 kHz to 100 kHz
0.02% above 220 V  to 1000 V and from 15 Hz to 40 Hz
0.03% above 220 V to 1100 V and from 40 Hz to 20 kHz
0.08% above 220 V to 750 V and from 20 kHz to 50 kHz 

DC voltage Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -

0.002% + 0.2 μV from 0.01 to 0.22 V
0.001% + 0.2 μV above 0.22 V to 2.2 V
0.001% + 1.3 μV above 2.2 V to 11 V
0.003% + 3 μV above 11 V to 22 V
0.005% + 33 μV above 22 V to 220 V
0.002% + 164 μV above 220 V to 1100 V 

Current clamps AC current; DC current Comparison with a reference standard

Capability

including verification of time interval

DC Clamp Meters

with Calibration and Measurement Capability of -

0.34% from 20 A to 1000 A 

AC Clamp Meters

with Calibration and Measurement Capability of -

0.34% from 20 A up to 1000 A and from 45 Hz to 100 Hz
1% from 20 A up to 350 A above 100 Hz to 440 Hz 

Digital multimeters (DMM); Insulation resistance test equipment; Ohm meters Resistance Comparison with a reference standard

including megohmmeters up to 1 GΩ and up to 1000 V dc applied voltage

Capability

with Calibration and Measurement Capability of -

0.13% from 500 μΩ to less than 1 Ω
0.01% from 1 Ω to 5 Ω
0.005% above 5 Ω to 10 Ω
0.003% above 10 Ω to 1 MΩ
0.01% above 1 MΩ to 10 MΩ
0.07% above 10 MΩ to 1 GΩ 

Digital multimeters (DMM); LCR meters Capacitance Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -

0.1% from 10 pF to 100 μF and from 50 Hz to 1 kHz

DC and low frequency electrical metrology - Electrical standards Conductance boxes; Precision resistors; Resistance boxes Resistance Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -

0.13% from 500 μΩ to less than 1 Ω
0.01% from 1 Ω up to 5 Ω
0.005% from 5 Ω up to 10 Ω
0.003% from 10 Ω up to 1 MΩ
0.01% from 1 MΩ up to 10 MΩ
0.07% from 10 MΩ up to 1 GΩ

DC and low frequency electrical metrology - High-voltage/high-current standards and equipment High voltage test sets Voltage Comparison with a reference standard



Capability

with Calibration and Measurement Capability of -

0.2% from 1000 V up to 90 kV DC
0.4% from 1000 V up to 70 kV AC at 50 Hz 

Dimensional metrology - Engineering equipment and precision instruments Dial gauges Length measurements Comparison with a reference standard

For compliance with AS 2103, BS 907 and BS 2795 and JIS B7503 

Capability

with Calibration and Measurement Capability of -

1.2 μm for linear measurements up to 10 mm;
2.5 μm for linear measurements from 10 up to 25 mm
3.5 μm for linear measurements from 25 up to 100 mm

Electronic calipers; Vernier calipers Length measurements Comparison with a reference standard

for compliance with AS 1984, BS 887 and JIS B7507 


Capability

with Calibration and Measurement Capability of -

(10 + 0.01L) μm for indication errors where L is the scale value in mm up to 300 mm

External micrometers Length measurements Comparison with a reference standard

for compliance with AS 2102-1989, BS 870 and JIS B7502 

Capability

with Calibration and Measurement Capability of -

(1 + 0.01L) μm for indication errors where L is the length in mm up to 300 mm

Pressure metrology - Pressure and vacuum measuring equipment Digital pressure gauges; Mechanical pressure gauges; Pressure transducers; Vacuum gauges Gauge pressure; High vacuum Comparison with dead weight tester; Comparison with reference instrument

AS 1349

.

Electrical transducers with dc voltage, dc current or resistance outputs

Capability

with Calibration and Measurement Capability of -

0.035% or 5 Pa (whichever is greater) from -100 kPa to 2 MPa;

0.06% from above 2 MPa to 5.5 MPa;

0.09% from above 5.5 MPa to 14 MPa;

0.05% from above 14 MPa to 70 MPa;

Time and frequency metrology - Frequency, time and waveform measuring equipment Counters; Frequency meters Frequency Measurement against reference standard

Capability

with Calibration and Measurement Capability of -

1 in 107 from 100 mHz to 500 MHz

Tachometers Rotational speed Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -

0.013 rpm from 1 rpm to below 100 rpm
0.13 rpm from 100 rpm to below 1000 rpm
1.3 rpm from 1000 rpm to 99 999 rpm 

Time interval meters Time interval Measurement against reference standard

Capability

with Calibration and Measurement Capability of -

0.02% from 50 μs to 10 s

Torque - Torque measuring and testing equipment Torque transducers Torque Gravimetric measurement with reference beam BS 7882

Capability

With a Calibration and Measurement Capability of -
0.3% from 0.1 to 25 Nm
0.2% from above 25 to 1500 Nm
Torque - Torque measuring and testing equipmentincluding on site calibrations Torque wrenches Torque Comparison with a reference standard

Capability

Including on-site calibrations

With a Calibration and Measurement Capability of -

0.9% of indicated value from 0.1 Nm to 1500 Nm;

Vibration metrology - Vibration equipment Accelerometers Acceleration sensitivity; Frequency Comparison measurement against reference transducer; Direct measurement by electrical input

ISO 16063-21 


Capability

Accelerometers of a mass up to 270 grams in the acceleration range from 9.8 m/sto 98 m/s from 7 Hz to 10 kHz with a sensitivity from 3.0 pc/g to 100 pc/g (0.3 pC/ms-2 to 10.2 pC/ms-2), or 10 mV/g to 100 mV/g (1.0 mV/ms-2  to  10.2 mV/ms-2)

with Calibration and Measurement Capability of -
Limited by a maximum displacement of 4.04 mm P-P and a maximum peak force of 28 N
1.9% of reading over the frequency range 7 to 9 Hz
1.5% of reading over the frequency range 10 to 99 Hz
1.1% of reading at the frequency range 100 Hz
1.3% of reading over the frequency range 101 to 920 Hz
2.0% of reading over the frequency range 921 to 5000 Hz
2.4% of reading over the frequency range 5001 to 10 000 Hz

Velocity transducers Frequency; Velocity sensitivity Comparison measurement against reference transducer; Direct measurement by electrical input

Capability

Velocity transducers of a mass up to 270 grams, in the velocity range from 5 mm/s to 394 mm/s from 5 Hz to 10 kHz, with a sensitivity from 10 mV/in/s to 100 mV/in/s (0.394 V/ms-1 to 3.94 V/ms-1)

with Calibration and Measurement Capability of -

2.4% of reading over the frequency range 5 to 9 Hz
1.6% of reading over the frequency range 10 to 99 Hz
1.3% of reading over the frequency range 100 and 160 Hz
2.0% of reading over the frequency range 101 to 1000 Hz
2.0% of reading over the frequency range 1001 to 5000 Hz
2.5% of reading over the frequency range 5001 to 10 000 Hz 


The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.