National Association of Testing Authorities, Australia
Scope of Accreditation
SGS Australia Pty Ltd
Site
Traffic Systems
Accreditation No.
18628
Site No.
20054
Date of Accreditation
28 Jul 2008
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Speed and velocity - Speed measuring devices | Doppler (radar) equipment | Speed | Direct electrical measurement | Calibration in the laboratory of radar speed measuring devices ("K" and "Ka" bands only) in | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Laser equipment including LIDAR | Distance; Power; Speed | Direct measurement against a reference standard | Calibration in the laboratory of LIDAR speed measurement devices in accordance with AS 4691.2, clause 2.2, electrical simulation (speed only) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - Speed Measurement 0.06 m at calibrated base line at nominal 20 m Optical Power Measurement 2.3 μW from 2 μW to 60 μW 2.9 μW above 60 μW to 80 μW 4.4 μW above 80 μW to 120 μW | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Speedometers | Speed | By time and length measurement | Calibration of vehicle speed | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Time interval equipment | Frequency; Speed | Direct electrical measurement | Calibration in the laboratory of Laser Speed Measurement Simulators | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - Speed Measurement 3 Hz at 1 MHz; | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Speed and velocity - Speed measuring devicesincluding on site calibrations | Inductive loop devices - By electrical simulation | Speed | Direct electrical measurement | Calibration in the laboratory and in the field (indoor environment), including on-site calibration of inductive loop speed measurement devices, by electrical simulation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability including on-site calibration | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Piezoelectric devices - By electrical simulation | Speed | Direct measurement against a reference standard | Calibration in the laboratory and in the field (indoor environment), of piezo electric speed measurement devices, by electrical simulation | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability including on-site calibration | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Scanning LIDAR based speed measurement device | Angle; Distance; Speed; Time interval | Direct measurement against a reference standard | Calibration, in the laboratory or at Notting Hill site of scanning LIDAR based speed measurement devices. | | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability including on-site calibrationwith Calibration and Measurement Capability of - Distance measurement 0.051 m at 20 m Time interval measurement 0.000036 s from 1 s to 100 s for time base Angle measurement 1.6 mRad from -30 mRad to +30mRad for angular deviation Speed measurement (2.2127- 0.0071v)% from 30 km/h to 250 km/h (by electrical simulation) where v is speed in km/h | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Time interval equipment | Speed | Direct electrical measurement | Calibration, in the laboratory or at Notting Hill site of Target Simulators for scanning LIDAR based speed measurement devices | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability including on-site calibration (2.1484 - 0.0072ν)% from 30 km/h to 250 km/h (by electrical simulation) (−2.0642 + 0.0097ν)% from 250 km/h to 280 km/h (by electrical simulation) where ν is speed in km/h | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Speed and velocity - Verification of fixed speed detector installations | Inductive loop speed measurement systems | Field measurement of DC resistance; Field measurement of inductance; Field measurement of insulation resistance | Direct electrical measurement | FIXED DIGITALSAFETY CAMERA TESTS | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability including on-site verification On site measurement of static electrical properties for in road inductive loop sensorswith Calibration and Measurement Capability of - 0.09 Ω + 0.15% of reading from 0 Ω to 50 Ω 0.11 Ω + 0.05% of reading from 50 Ω to 500 Ω 0.0003 kΩ + 0.05% of reading from 500 Ω to 5 kΩ 0.003 kΩ + 0.05% of reading from 5 kΩ to 50 kΩ 0.03 kΩ + 0.05% of reading from 50 kΩ to 500 kΩ 0.0005 MΩ + 0.15% of reading from 500 kΩ to 5 MΩ 0.05 MΩ + 1.5% of reading from 5 MΩ to 50 MΩ 0.21 MΩ + 3% of reading from 50 MΩ to 100 MΩ 0.21 MΩ + 8% of reading from 100 MΩ to 500 MΩ quality factor measurement 0.008 inductance measurement 0.51 μH + 1% of reading from 20 μH to 159.1 μH 0.52 μH + 0.5% of reading from 159.1 μH to 1.591 mH 0.01 mH + 0.2% of reading from 1.591 mH to 1 H insulation resistance measurement 0.05 MΩ + 1.5% of reading from 10 kΩ to 20 MΩ 0.5 MΩ + 1.5% of reading from 20 MΩ to 200 MΩ 5.34 MΩ +1.5% of reading from 200 MΩ to 500 MΩ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Inductive loop speed measurement systems; Piezoelectric speed measurement systems | Speed | Comparison with a reference standard | Measurement by vehicle fitted with a calibrated speedometer, by reference TIRTL, by reference LIDAR as per SGS Speed Evaluation procedure | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - (0.0081v+0.29)/km/h from 30 km/h to 100 km/h, where V is the measured velocity in km/h based on TIRTL | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Timers in point to point speed detectors | Time interval | Comparison with a reference standard | Point to Point timer Evaluation | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Verification of the timer used in Point to Point Speed detectors, (excludes verification of the detectors triggering devices). By comparison of the detector’s timer against a reference timer.with Calibration and Measurement Capability of - (0.13)s from 1 s to 29000 s (1.7E-6*t + 0.083)s from 29000 s to 86400 s, where “t” is the elapsed time in seconds | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Traffic signal phase systems | Time interval | Comparison with a reference standard | In-house SGS Traffic Signal Procedure | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability With Calibration and Measurement Capability of -0.3 s from 0.0 to 180.0 s | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Speed and velocity - Verification of fixed speed detector installationsincluding on site calibrations | Piezoelectric speed measurement systems | Field measurement of DC resistance; Field measurement of capacitance; Field measurement of voltage | Direct electrical measurement | FIXED DIGITALSAFETY CAMERA TESTS In-road piezoelectric sensor evaluation as follows:- by on-site measurement of static electrical properties - by on-site measurement of dynamic electrical properties - waveform analysis of the piezoelectric sensor response to road traffic | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability including on-site verification capacitance measurement with least uncertainties of measurement of - 0.03 nF + 0.5% of reading from 1 nF to 1 μF dissipation factor measurement with least uncertainties of measurement of 0.0051 0.09 Ω + 0.15% of reading from 0 Ω to 50 Ω 0.21 mV + 0.025% of reading from 0 mV to 5 V 0.003 V + 0.025% of reading from 5 V to 50 V 0.021 V + 0.03% of reading from 50 V to 500 V 0.21 V + 0.03% of reading from 500 V to 1000 V waveform analysis of the piezoelectric sensor response to road traffic 0.1 mV + 3.5% of reading from 0 mV to 300 V | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Time and frequency metrology - Frequency and time standards | Signal sources | Coordinated universal time (UTC) | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Timers in variable speed video monitoring systemsIncluding on site calibrations with Calibration and Measurement Capability of - 0.17 s |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.