
National Association of Testing Authorities, Australia
Scope of Accreditation
Vipac Engineers and Scientists Ltd
Site
Traffic Systems
Accreditation No.
676
Site No.
15858
Date of Accreditation
15 Dec 1969
Address
Victorian Technology Centre, 275-283 Normanby Road
Port Melbourne, VIC 3207
Australia
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Speed and velocity - Speed measuring devices | Vehicle with digital display | Speed | Direct measurement against a reference standard | Vipac Method LI8447 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - in the range 30 to 110 km/h0.5 km/h at speeds of 30 to 45 km/h; 0.7 km/h at speeds of 45 to 65 km/h; 0.9 km/h at speeds of 65 to 80 km/h; 1.2 km/h at speeds of 80 to 110 km/h; | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Speed and velocity - Verification of fixed speed detector installations | Inductive loop speed measurement systems; Piezoelectric speed measurement systems; Traffic signal phase systems | Field measurement of AC resistance | Direct electrical measurement | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - at 1 kHz in the range 0.1 Ω to 200 Ω0.05 Ω or 8.3% of reading, whichever is greater | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Field measurement of insulation resistance | Direct electrical measurement | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 7.6% of reading in the range from 100 kΩ to 500 MΩ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Field measurement of voltage | Direct electrical measurement | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - Voltage measuring equipment (picoscope)stored waveforms in the range 10 mV to 20 V 5 mV or 5 % of reading, whichever is greater | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Field measurement of inductance | Direct electrical measurement | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 1 kHz in the range 10 μH to 2 mH0.5 μH or 1.5% of reading, whichever is greater | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Field measurement of DC resistance | Direct electrical measurement | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 0.05 Ω in the range from 0.1 Ω to 200 Ω | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Field measurement of capacitance | Direct electrical measurement | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - at 1 kHz in the range 0.5 nF to 1 μF0.1 nF or 0.6% of reading, whichever is greater |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
676
Site No.
15858
Print date
27 Apr 2025