Scope of Accreditation

Withdrawn 11 May 2026

Voluntary

UPT Laboratory

ISO/IEC 17025 (2005)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Withdrawn
Service Product Determinant Technique Procedure Limitations
Pressure metrology - Pressure and vacuum measuring equipment Pressure control devices; Pressure gauges; Pressure recorders; Pressure transducers; Vacuum gauges Gauge pressure By pressure calibrator; Comparison with dead weight tester; Comparison with reference instrument

AS 1349 

MSA Test Method 1

MSA Test Method 2

UPT method UPT_Q_WMS_005 Section 11.4 

-90 kPa to 0 kPa and 20 kPa to 260 MPa

Capability

0.07% of reading or 0.005 kPa (whichever is the greater) from -90 kPa to 0 kPa
0.03% of reading from 20 kPa to 1 MPa
0.015% of reading from 1 MPa to 200 MPa
0.025% of reading from 200 MPa to 260 MPa

Torque - Torque measuring and testing equipment Torque wrenches Torque Comparison with a reference standard

clockwise and anti-clockwise for compliance with ISO 6789 and AS 4115

1.25 N.m to 1500 N.m.

Capability

1.5 % of reading

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Withdrawn
Service Product Determinant Technique Procedure Limitations
Evaluation of mechanical performance of pressure equipment Hose and hose assemblies Hydrostatic pressure Not applicable ISO 1402
Piping Pneumatic pressure Not applicable AS 4041 (Section 6.8.1),
ASME B31.3 (Chapter VI Section 345)
up to 70 MPa
Hydrostatic pressure Not applicable AS 4041 (Section 6.7),
ASME B31.3 (Chapter VI Section 345)
up to 70 MPa
Pressure fittings; Pressure vessels Pneumatic pressure Not applicable AS 1210 (Section 5.11),
AS 4037 (Section 18),
ASME VIII (Division 1 - Section UG-100)
up to 70 MPa
Hydrostatic pressure Not applicable AS 1210 (Section 5.10),
AS 4037 (Section 17),
ASME VIII (Division 1 - Section UG-99)
up to 70 MPa
Valves Hydrostatic pressure Not applicable API 527 (Section 4),  
API 576 (Appendix A)
Pressure relief valves up to 70 MPa
Pneumatic pressure Not applicable API 527 (Section 5),  
API 576 (Appendix A)
Pressure relief valves up to 70 MPa
Evaluation of mechanical performance of pressure plant, pipelines and equipment High pressure oil and gas pipelines Strength, leak and combined pressure evaluation Not applicable AS/NZS 2885.5 (Section 7) up to 70 MPa
Hose and hose assemblies Hydrostatic pressure Not applicable ISO 1402
Piping Hydrostatic pressure Not applicable AS 4041 (Section 6.7);
ASME B31.3 (Chapter VI Section 345)
up to 70 MPa
Pneumatic pressure Not applicable AS 4041 (Section 6.8.1); 
ASME B31.3 (Chapter VI Section 345)
up to 70 MPa
Pressure fittings; Pressure vessels Pneumatic pressure Not applicable

AS 1210 (Section 5.11);
AS 4037 (Section 18);
ASME VIII (Division 1 - Section UG-100)

up to 70 MPa

Hydrostatic pressure Not applicable

AS 1210 (Section 5.10); 

AS 4037 (Section 17); 

ASME VIII (Division 1 - Section UG-99)

up to 70 MPa

Valves Hydrostatic pressure Not applicable API 527 (Section 4);  
API 576 (Appendix A)
Pressure relief valves up to 70 MPa
Pneumatic pressure Not applicable API 527 (Section 5);  
API 576 (Appendix A)
Pressure relief valves up to 70 MPa
Water pipelines Hydrostatic pressure Not applicable AS/NZS 2566.2 (Section 6.3 and Appendix M) up to 120 MPa
Leakage Not applicable AS/NZS 2566.2 (Section 6.4 and Appendix N) up to 120 MPa
Evaluation of mechanical performance of water and sewer pipelines Water pipelines Hydrostatic pressure Not applicable AS/NZS 2566.2 (Section 6.3 and Appendix M) Up to 69 MPa including on-site testing.
Leakage Not applicable AS/NZS 2566.2 (Section 6.4 and Appendix N) Up to 120 MPa