National Association of Testing Authorities, Australia
Scope of Accreditation
WA Calibrations Pty Ltd
Site
WA Calibrations
Accreditation No.
20838
Site No.
25011
Date of Accreditation
10 May 2021
Contact
Mr Wade Adam P: +61 0430672385
Availability
Services available to external clients
Scope of Accreditation
WA Calibrations
ISO/IEC 17025 (2017)
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Calibration
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mass - Determination of mass and calibration of weighing devices | Laboratory weighing devices; Precision laboratory balances | Mass | Direct measurement | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including on-site calibrationswith calibration and measurement capability of - 1 in 106 or 10 µg (whichever is greater) up to 220 g 10 mg above 220 g to 4 kg 20 mg above 4 kg to 10 kg 100 mg above 10 kg to 20 kg 200 mg above 20 kg to 35 kg | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Mass standards | Mass | Direct measurement | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with calibration and measurement capability of –10 µg from 1 mg to 1 g 15 µg above 1 g to 2 g 20 µg above 2 g to 5 g 25 µg above 5 g to 10 g 30 µg above 10 g to 20 g 50 µg above 20 g to 50 g 100 µg above 50 g to 100 g 200 µg above 100 g to 200 g 10 mg above 200 g to 2 kg 20 mg above 2 kg to 5 kg 50 mg above 5 kg to 10 kg | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature metrology - Ancillary temperature measuring equipment | Digital voltmeters (DVM) and digital multimeters (DMM); Multi-channel thermocouple data recorders; Process calibrators | Volt to temperature conversion | Direct measurement by electrical input | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including on-site calibrationswith Calibration and Measurement Capability of - 0.2% of reading or 0.6 ºC (whichever is greater) in the range from -40 ºC to 1200 ºC (Type K thermocouple only) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature metrology - Temperature measuring equipment | Digital temperature measuring systems | Temperature | Comparison with a reference standard | By in house method WAC CM01 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including on-site calibrationswith Calibration and Measurement Capability of - 0.5 °C in the range from -196 °C to below -40 °C 0.1 °C in the range from -40 °C to 150 °C 0.3 °C in the range above 150 °C to 250 °C 0.5 °C in the range above 250 °C to 650 °C | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature metrology - Temperature standards and reference equipment | Dry block calibrators | Temperature | Direct measurement using a reference standard | By in house method WAC CM05 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including on-site calibrationswith Calibration and Measurement Capability of - 0.2 °C in the range from -40 °C to 150 °C 0.3 °C in the range above 150 °C to 650 °C | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature metrology - Verification of controlled enclosures | Baths; Freezers; Furnaces; Incubators; Ovens | Temperature | Direct temperature measurement | IEC 60068-3-5 (excluding rate of change of cooling and heating tests) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including on-site calibrationswith Calibration and Measurement Capability of - 1 °C in the range from -40 °C to 200 °C 8 °C in the range above 200 °C to 1200 °C | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Medical refrigeration equipment | Spatial uniformity; Temperature | Direct temperature measurement | AS 3864.2 (excluding clause 3.6.4) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including on-site calibrationswith Calibration and Measurement Capability of 0.8 °C from -40 °C to below 0 °C 0.3 °C from 0 °C to 10 °C | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Volume and density - Laboratory volumetric glassware and measures | Piston operated volumetric apparatus (POVA) | Volume | Gravimetric | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with calibration and measurement capability of –0.02 µL from 0.25 µL to 2.5 µL 0.04 µL above 2.5 µL to 20 µL 0.3 µL above 20 µL to 200 µL 1.5 µL above 200 µL to 1000 µL 6 µL above 1000 µL to 5000 µL 11 µL above 5000 µL to 10000 µL |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
20838
Site No.
25011
Print date
22 Dec 2024
END OF SCOPE