Accredited Test Services

Site

Accredited Test Services

Accreditation No.

502

Site No.

495

Date of Accreditation

07 Dec 1965

Address

2153 Melbourne-Lancefield Road
Monegeetta, VIC 3433
Australia

Contact

Mr Vince Marino P: +61 (03) 54280413

Availability

Services conditionally available to external clients

Scope of Accreditation

Accredited Test Services

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
Force metrology - Force measuring and testing equipment Load cells Force in compression; Force in tension Comparison measurement with reference load cell

From 1 kN to 90 kN

Capability

With calibration and measurement capability of-

0.5 % of reading From 1 kN to 90 kN

Pressure metrology - Pressure and vacuum measuring equipment Digital pressure gauges; Mechanical pressure gauges; Pressure transducers Gauge pressure By pressure calibrator; Comparison with dead weight tester; Comparison with reference instrument AS 1349 10 kPa to 120 MPa

Capability

with calibration and measurement capability of -

0.06% of reading from 10 kPa to 120 MPa

Piezoelectric pressure transducer (blast pencils); Pressure transducers Dynamic pressure Comparison with a reference transducer from 3.5 kPa (0.5psi) to 345 kPa (50psi)

Capability

with calibration and measurement capability of -
1% of reading from 3.5 kPa to 345 kPa
Vibration metrology - Vibration equipment Accelerometers; Vibration measuring systems Acceleration sensitivity Comparison measurement against reference transducer

from 9.8 m/s2 to 490 m/s2 (1 to 50 gn)

Capability

with calibration and measurement capability of -


Calibration of accelerometers of mass less than 100 g
at accelerations from 9.8 m/s2 to 490 m/s2 (1 to 50 gn)
0.6% of sensitivity from 0.5 Hz up to 10 Hz

0.8% of sensitivity from 11 Hz to 5000 Hz
Calibration of shock accelerometers of mass less than 40 g
from 9.9 x 102 to 9.8 x 104 m/s2 (100 to 10,000 gn)
3.0% of sensitivity with half sine pulse width from 0.1 to 1 ms.

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Measurement of sound levels in workplaces and the environment Electrical machinery; Industrial, earthmoving and agricultural vehicles; Machinery other than electrical machinery; Road traffic; Weapons Sound pressure level Microphone QDAL-INST-103, QDAL-INST-105,
QDAL-INST-107, QDAL-INST-108,
Environments impacted by noise or vibration; Occupied spaces Community noise assessments; Occupational noise exposure level Microphone

QDAL-INST-104

Vibration analysis - Vibration levels in workplaces and the environment Electrical machinery; Environments impacted by noise or vibration; Industrial, earthmoving and agricultural vehicles; Machinery other than electrical machinery; Motor vehicles; Occupied spaces Vibration exposure; Vibration level Geophone QDAL-INST-101, QDAL-INST-102

ISO/IEC 17025 (2017)

Manufactured Goods

Service Product Determinant Technique Procedure Limitations
Electromagnetic compatibility (EMC) - Emissions - Military Electrical and electronic products Conducted emissions Not applicable MIL-STD-461 D, E, F, G; Method CE 102 CE 102 Conducted emissions, power leads, 10 kHz to 10 MHz
Radiated emissions Not applicable MIL-STD-461 D, E, F, G; Method RE 102 RE 102 Radiated emissions, electric field at 1 m; 10 kHz to 18 GHz
Electromagnetic compatibility (EMC) - Immunity - Military Electrical and electronic products; Power leads Radiated susceptibility Not applicable MIL-STD-461 D, E, F; G; Method RS 101, RS 103 RS 101 Radiated susceptibility, magnetic field, 30 Hz to 100 kHz;
RS 103 Radiated susceptibility, electric field, 10 Hz to 18 GHz
Conducted susceptibility Not applicable MIL-STD-461 D, E, F, G: Methods CS 101, CS 114, CS 115, CS 116 CS 101 Conducted susceptibility, power leads, 30 Hz to 50 kHz;
CS 114 Conducted susceptibility, bulk cable injection, 10 kHz to 400 MHz;
CS 116 Conducted susceptibility, bulk cable injection, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz
Evaluation of consumer and industrial lighting, optical systems and eyewear Image intensification devices Resolution USAF test pattern

QECL-INST-O01

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.