National Association of Testing Authorities, Australia
Scope of Accreditation
Accredited Test Services
Scope of Accreditation
Accredited Test Services
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Measurement of sound levels in workplaces and the environment | Electrical machinery; Industrial, earthmoving and agricultural vehicles; Machinery other than electrical machinery; Road traffic; Weapons | Sound pressure level | Microphone | QDAL-INST-103, QDAL-INST-105, QDAL-INST-107, QDAL-INST-108, | |
Environments impacted by noise or vibration; Occupied spaces | Community noise assessments; Occupational noise exposure level | Microphone | QDAL-INST-104 | ||
Vibration analysis - Vibration levels in workplaces and the environment | Electrical machinery; Environments impacted by noise or vibration; Industrial, earthmoving and agricultural vehicles; Machinery other than electrical machinery; Motor vehicles; Occupied spaces | Vibration exposure; Vibration level | Geophone | QDAL-INST-101, QDAL-INST-102 |
ISO/IEC 17025 (2017)
Manufactured Goods
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Electromagnetic compatibility (EMC) - Emissions - Military | Electrical and electronic products | Conducted emissions | Not applicable | MIL-STD-461 D, E, F, G; Method CE 102 | CE 102 Conducted emissions, power leads, 10 kHz to 10 MHz |
Radiated emissions | Not applicable | MIL-STD-461 D, E, F, G; Method RE 102 | RE 102 Radiated emissions, electric field at 1 m; 10 kHz to 18 GHz | ||
Electromagnetic compatibility (EMC) - Immunity - Military | Electrical and electronic products; Power leads | Radiated susceptibility | Not applicable | MIL-STD-461 D, E, F; G; Method RS 101, RS 103 | RS 101 Radiated susceptibility, magnetic field, 30 Hz to 100 kHz; RS 103 Radiated susceptibility, electric field, 10 Hz to 18 GHz |
Conducted susceptibility | Not applicable | MIL-STD-461 D, E, F, G: Methods CS 101, CS 114, CS 115, CS 116 | CS 101 Conducted susceptibility, power leads, 30 Hz to 50 kHz; CS 114 Conducted susceptibility, bulk cable injection, 10 kHz to 400 MHz; CS 116 Conducted susceptibility, bulk cable injection, damped sinusoidal transients, cables and power leads, 10 kHz to 100 MHz | ||
Evaluation of consumer and industrial lighting, optical systems and eyewear | Image intensification devices | Resolution | USAF test pattern | QECL-INST-O01 |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
502
Site No.
495
Print date
26 Dec 2024
END OF SCOPE