Acoustic Research Labs Pty Ltd

Site

Acoustic Research Labs Pty Ltd

Accreditation No.

14172

Site No.

14165

Date of Accreditation

11 Feb 1999

Address

36/14 Loyalty Road
North Rocks, NSW 2151
Australia

acousticresearch.com.au

Contact

Mr Ken Williams P: +61 (02) 94840800

Availability

Services available to external clients

Scope of Accreditation

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
Acoustical metrology - Acoustic equipment Band pass filters Frequency response Direct measurement by electrical input IEC-61260-3



Capability

With Calibration and Measurement Capability of - 

Band Pass filters

0.1 dB for attenuation equal to and less than 40 dB 

0.2 dB for attenuation from above 40 dB to 60 dB
Sound level meters Electrical response; Sound pressure level Direct measurement by electrical input; Direct measurement by reference sound source

AS 1259.1 - 1990 Clauses 8.9, 8.10, 10.1, 10.2.2, 10.2.3, 10.3.2, 10.3.3, 10.3.4, 10.4.2, 10.4.3, 10.4.4, 10.4.5

AS 1259.2 - 1990 Clauses 9.1, 9.2.1, 9.2.2, 9.2.3, 9.3.1, 9.3.2, 9.3.3, 9.3.5

IEC 60651, IEC 60804, IEC 61672-3

Capability

With Calibration and Measurement Capability of - 

Acoustic tests using a multi function acoustic calibrator
0.14 dB at 31.5 Hz
0.13 dB at 63 Hz to 125 Hz  
0.12 dB at 250 Hz to 500 Hz
0.13 dB at 1 kHz to 2 kHz
0.14 dB at 4 kHz to 8 kHz
0.16 dB at 12.5 kHz
0.22 dB at 16 kHz


Electrical tests
0.1 dB from 10 Hz to 24 kHz


Acoustical metrology - Acoustic standards and reference equipment Acoustic calibrators - Multi frequency Distortion; Frequency; Sound pressure level Direct measurement against reference signal IEC 60942:2017 Excluding Class LS

Capability

With Calibration and Measurement Capability of -
0.11 dB at 250 Hz and 1 kHz for sound pressure level
0.002% for frequency
0.5% for total harmonic distortion



The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.