AmSpec Australia Pty Ltd

Site

AmSpec Technical Services

Accreditation No.

9475

Site No.

9468

Date of Accreditation

03 May 1994

Address

8 Edison Circuit
Rockingham, WA 6168
Australia

amspecgroup.com

Contact

Mr Alan Pillinger P: +61 (08) 93398222

Availability

Services available to external clients

Scope of Accreditation

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
Volume and density - Industrial volumetric equipment and bulk storageincluding on site calibrations Bulk storage tanks Volume Comparison with a reference meter; Scanning length measurement; Strapping length method

Calibration of upright cylindrical tanks, by an optical reference line method or a laser total station method to ISO 7507-1,  ISO 7507-2 and API 653

Calibration of upright cylindrical tanks, by 3D laser scanner
by the in-house method (for raw volumes),  ISO 7507-1 and API 653

Calibration of horizontal and inclined cylindrical steel tanks
by strapping method to API 2551

Calibration of horizontal and inclined cylindrical steel tanks by 3D laser scanner
by the in-house method (for raw volumes) and API2551

Calibration of vertical, horizontal and inclined cylindrical steel tanks and spherical and spheroid tanks by liquid calibration methods

Calibration of spherical and spheroid tanks by strapping or 3D Laser scanner

From 20 L to 40 ML

Capability

Including on site calibrations

with Calibration and Measurement Capability of -

Upright cylindrical tanks by an optical reference line method or a laser total station method
0.38% of volume from 500 kL to 3 ML
0.05% of volume from 3 ML to 40 ML

Upright cylindrical tanks by 3D laser scanner

0.06% of volume from 5000 kL to 40 ML

Horizontal and inclined cylindrical steel tanks

0.32% of volume from 1 kL to 150 kL

Vertical, horizontal and inclined cylindrical steel thanks and spherical and spheroid tanks 

0.25% of volume from 20 L to 100 kL

Calibration of spherical and spheroid tanks by strapping or 3D Laser scanner
0.05% of volume  from 100 kL to 4 ML

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of mechanical performance of pressure plant, pipelines and equipment Hose and hose assemblies Hydrostatic pressure Not applicable

AS 2117, AS 2683 (in-service performance tests),

BS EN ISO 1402, 

OCIMF guidelines

in the range 0 to 3000 kPa

Low pressure oil and gas pipelines Hydrostatic pressure Not applicable

AS/NZS 2566.2 Appendix M except visco-elastic pressure pipelines to Appendix M5, AS 2885.5


in the range 0 to 3000 kPa

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.