National Association of Testing Authorities, Australia
Scope of Accreditation
ALTRAD APTS Pty Ltd
Site
APTS (WA)
Accreditation No.
14921
Site No.
15086
Date of Accreditation
09 Aug 2004
Contact
Mr Matthew Ricciardo P: +61 (08) 94121500
Availability
Services available to external clients
Scope of Accreditation
APTS (WA)
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of mechanical performance of high pressure oil and gas pipelines | High pressure oil and gas pipelines | Strength, leak and combined pressure evaluation | Not applicable | AS 2885.5 Section 6; AS/NZS 4645.2 section 6;; AS/NZS 5601.1 Appendix E; ASME B31.8 Section 841.3 and Appendix N; API RP 1110; DNVGL-ST-F101 Sections 8.7 and 10.10.3; ISO 14692-4 Section 4.6.2; ASME B 31.4 Section 437.4 | Up to 260 MPa. |
Evaluation of mechanical performance of low pressure oil and gas pipelines | Low pressure oil and gas pipelines | Strength, leak and combined pressure evaluation | Not applicable | APGA Code of Practice Section 8; AS 2885.5 Section 6; AS/NZS 2033 Sections 7.2, 7.3 and 7.3.3; AS/NZS 4645.2 section 6; AS/NZS 5601.1 Appendix E; ASME B31.8 Section 841.3 and Appendix N; API RP 1110; DNVGL-ST-F101 Sections 8.7 and 10.10.3; ISO 14692-4 Section 4.6.2; ASME B 31.4 Section 437.4 | Up to 70 MPa. |
Evaluation of mechanical performance of pressure equipment | Hose and hose assemblies | Burst pressure; Hydrostatic pressure | Not applicable | AS 1180.5 (1999) Sections 7.1 and 7.3; AS 3791 Methods 5A, 5B and 5D; AS 4233.1 Appendix E; ISO 1402 Sections 8.1, 8.3 and 8.4 | Up to 413 MPa including on-site testing. |
Piping; Pressure fittings | Pneumatic pressure | Not applicable | AS 4037 Sections 18 and 19.1, AS 4041 Sections 6.6, 6.8.1 and 6.9, ASME B31.3 section 345, AS/NZS 1200 Appendix J4.2.3, AS/NZS 3788 Appendix D16, AS/NZS 5601.1 Appendix E, in-house method TM-04 | Up to 100 MPa including on-site testing. | |
Hydrostatic pressure | Not applicable | AS 1851 Section 8.4, AS 2117 Section 2.2, AS 2419.2, AS 2885.5 Section 7, AS 3500.1 Section 18.3.1, AS 4037 Section 17, AS 4041 Sections 6.6 and 6.7, AS/NZS 1200 Appendices J4.2.3 and J7.5, AS/NZS 1462.8 Section 7.1.3, AS/NZS 1477 Section 3.3.6, AS/NZS 2033 sections 7.2 and 7.3, AS/NZS 2280 Section 4 and Appendix F, AS/NZS 2566.2 Section 6.3.4.5 and Appendix M8, AS/NZS 3788 Appendix D15, AS/NZS 4058, ASME B31.3 Section 345, ASME B31.4 Section 437.4, DNVGL-ST-F101 Section 8.7, in-house methods TM-01 and TM-03, ISO 14692-4 Section 4.6.2 | Up to 413 MPa including on-site testing. | ||
Pressure vessels | Hydrostatic pressure | Not applicable | AS/NZS 1200 Appendix J4.2.3 and J7.5; AS 1210 Section 5.10, AS 1692 Section 2.8.2; AS 4037 Section 17, AS 4041 Sections 6.6 and 6.7, API 620 Sections 7.18 and 7.19; API 650 Sections 7.3.6 and 7.3.7; in-house method TM-05 | Up to 413 MPa including on-site testing. | |
Burst pressure; Pneumatic pressure | Not applicable | API 650 Sections 7.3.5 and 7.3.8; AS/NZS 1200 Appendix J4.2.3; AS 1210 Section 5.11; AS 1692 Section 2.8.3; AS 3791; AS 4037 Section 18;; in-house method TM-04 | Up to 100 MPa including on-site testing. | ||
Valves | Pneumatic pressure | Not applicable | API 526 Section 9, API 527 Section 2, API 620 Section 9, AS 1271 section 3.4, in-house method TM-01 | Up to 100 MPa including on-site testing. | |
Hydrostatic pressure | Not applicable | API 526 Section 9; API 527 Section 4; AS 1271 Sections 2.6 and 3.4; AS 4795.2 Sections 5.2.1, 5.2.2, 5.2.3, 5.2.6, 5.3.2, 5.3.3, 5.3.4, 5.3.5 and 5.3.6; in-house method TM-01 | Up to 413 MPa including on-site testing. | ||
Evaluation of mechanical performance of water and sewer pipelines | Sewer pipelines | Strength, leak and combined pressure evaluation | Not applicable | AS/NZS 2033 sections 7.2, 7.3 and 7.3.3; AS/NZS 2566.2 Sections 6.3.4, 6.4.2, 6.4.4, Appendix M and Appendix N, AS/NZS 4645.3 Section 6 | AS/NZS 2566.2 Appendix N (excluding N5) Up to 70 MPa. |
Water pipelines | Strength, leak and combined pressure evaluation | Not applicable | APGA Code of Practice Section 8; AS/NZS 2033 sections 7.2, 7.3 and 7.3.3; AS/NZS 2566.2 Sections 6.3.4, 6.4.2, 6.4.4, Appendix M and Appendix N (excluding N5) | Up to 70 MPa. |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
14921
Site No.
15086
Print date
07 Oct 2024