ALTRAD APTS Pty Ltd

Site

APTS (WA)

Accreditation No.

14921

Site No.

15086

Date of Accreditation

09 Aug 2004

Address

4 Beach Street
Kwinana Beach, WA 6167
Australia

apts.com.au

Contact

Mr Matthew Ricciardo P: +61 (08) 94121500

Availability

Services available to external clients

Scope of Accreditation

APTS (WA)

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of mechanical performance of high pressure oil and gas pipelines High pressure oil and gas pipelines Strength, leak and combined pressure evaluation Not applicable AS 2885.5 Section 6; AS/NZS 4645.2 section 6;; AS/NZS 5601.1 Appendix E; ASME B31.8 Section 841.3 and Appendix N; API RP 1110; DNVGL-ST-F101 Sections 8.7 and 10.10.3; ISO 14692-4 Section 4.6.2; ASME B 31.4 Section 437.4 Up to 260 MPa.
Evaluation of mechanical performance of low pressure oil and gas pipelines Low pressure oil and gas pipelines Strength, leak and combined pressure evaluation Not applicable APGA Code of Practice Section 8; AS 2885.5 Section 6; AS/NZS 2033 Sections 7.2, 7.3 and 7.3.3; AS/NZS 4645.2 section 6; AS/NZS 5601.1 Appendix E; ASME B31.8 Section 841.3 and Appendix N; API RP 1110; DNVGL-ST-F101 Sections 8.7 and 10.10.3; ISO 14692-4 Section 4.6.2; ASME B 31.4 Section 437.4 Up to 70 MPa.
Evaluation of mechanical performance of pressure equipment Hose and hose assemblies Pneumatic pressure Not applicable AS 1180.5 (1999) Sections 7.1 and 7.3, AS 3791, in-house method TM-18, ISO 1402 Sections 8.1, 8.3 and 8.4 Up to 100 MPa including on-site testing.
Burst pressure; Hydrostatic pressure Not applicable AS 1180.5 (1999) Sections 7.1 and 7.3; AS 3791 Methods 5A, 5B and 5D; AS 4233.1 Appendix E; ISO 1402 Sections 8.1, 8.3 and 8.4 Up to 413 MPa including on-site testing.
Piping; Pressure fittings Pneumatic pressure Not applicable AS 4037 Sections 18 and 19.1, AS 4041 Sections 6.6, 6.8.1 and 6.9, ASME B31.3 section 345, AS/NZS 1200 Appendix J4.2.3, AS/NZS 3788 Appendix D16, AS/NZS 5601.1 Appendix E, in-house method TM-04 Up to 100 MPa including on-site testing.
Hydrostatic pressure Not applicable  AS 1851 Table 8.4 item 1.4, AS 2117 Section 2.2, AS 2419.2, AS 2885.5 Section 7, AS 3500.1 Section 18.3.1, AS 4037 Section 17, AS 4041 Sections 6.6 and 6.7, AS/NZS 1200 Appendices J4.2.3 and J7.5, AS/NZS 1462.8 Section 7.1.3, AS/NZS 1477 Section 3.3.6, AS/NZS 2033 sections 7.2 and 7.3, AS/NZS 2280 Section 4 and Appendix F, AS/NZS 2566.2 Section 6.3.4.5 and Appendix M8, AS/NZS 3788 Appendix D15, AS/NZS 4058, ASME B31.3 Section 345, ASME B31.4 Section 437.4, DNVGL-ST-F101 Section 8.7, in-house methods TM-01 and TM-03, ISO 14692-4 Section 4.6.2 Up to 413 MPa including on-site testing.
Pressure vessels Hydrostatic pressure Not applicable AS/NZS 1200 Appendix J4.2.3 and J7.5; AS 1210 Section 5.10, AS 1692 Section 2.8.2; AS 4037 Section 17, AS 4041 Sections 6.6 and 6.7, API 620 Sections 7.18 and 7.19; API 650 Sections 7.3.6 and 7.3.7; in-house method TM-05 Up to 413 MPa including on-site testing.
Burst pressure; Pneumatic pressure Not applicable API 650 Sections 7.3.5 and 7.3.8; AS/NZS 1200 Appendix J4.2.3; AS 1210 Section 5.11; AS 1692 Section 2.8.3; AS 3791; AS 4037 Section 18;; in-house method TM-04 Up to 100 MPa including on-site testing.
Valves Pneumatic pressure Not applicable API 526 Section 9, API 527 Section 2,  API 620 Section 9, AS 1271 section 3.4, in-house method TM-01 Up to 100 MPa including on-site testing.
Hydrostatic pressure Not applicable API 526 Section 9; API 527 Section 4; AS 1271 Sections 2.6 and 3.4; AS 4795.2 Sections 5.2.1, 5.2.2, 5.2.3, 5.2.6, 5.3.2, 5.3.3, 5.3.4, 5.3.5 and 5.3.6; in-house method TM-01 Up to 413 MPa including on-site testing.
Evaluation of mechanical performance of water and sewer pipelines Sewer pipelines Strength, leak and combined pressure evaluation Not applicable AS/NZS 2033 sections 7.2, 7.3 and 7.3.3; AS/NZS 2566.2 Sections 6.3.4, 6.4.2, 6.4.4, Appendix M and Appendix N, AS/NZS 4645.3 Section 6 AS/NZS 2566.2 Appendix N (excluding N5)
Up to 70 MPa.
Water pipelines Strength, leak and combined pressure evaluation Not applicable APGA Code of Practice Section 8; AS/NZS 2033 sections 7.2, 7.3 and 7.3.3; AS/NZS 2566.2 Sections 6.3.4, 6.4.2, 6.4.4, Appendix M and Appendix N (excluding N5) Up to 70 MPa.

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.