CabLab Pty Ltd

Site

CabLab Pty Ltd

Accreditation No.

20053

Site No.

23591

Date of Accreditation

07 Feb 2017

Address

Unit 4, 174 - 186 Atlantic Drive
Keysborough, VIC 3173
Australia

cablab.com.au

Contact

Mr Istvan Szecsei P: +61 (03) 97984452

Availability

Services available to external clients

Scope of Accreditation

CabLab Pty Ltd

ISO/IEC 17025 (2017)

Manufactured Goods

Service Product Determinant Technique Procedure Limitations
Electrical equipment approval and safety evaluation Electrical cables, cords and conductors Electrical performance of electrical cables, cords and conductors Capacitance; Conductor resistance; Current; Dielectric; Electric field intensity; Electrical continuity; High voltage; Impulse voltage withstand; Insulation resistance; Load cycle; Partial discharge; Sequence impedance; Spark; Surface leakage; Tan ? measurement; Voltage; Volume resistivity

AS/NZS 3808 excluding Acid and corrosive gas emission, Melt flow index, Carbon black content, Carbon black dispersion, Environmental stress crack resistance;

AS/NZS 1125;

AS/NZS 1660.1 excluding Metal plating tests of clause 4.1, clause 4.2 and clause 4.3;

AS/NZS 1660.2.1 excluding tests at low temperature for insulation and sheath of clause 2.3;

AS/NZS 1660.2.2;

AS/NZS 1660.2.3 excluding clause 2.5;

AS/NZS 1660.2.5;

AS/NZS 1660.3 excluding clauses 3.8 to 3.12, 3.14 and 3.15; 

AS/NZS 1660.5.6:2005;
AS/NZS IEC 60332.1.1;
AS/NZS IEC 60332.1.2;
AS/NZS IEC 60332.1.3;

AS/NZS 3191 excluding Appendix C;

AS/NZS 5000.1;

AS/NZS 5000.2;

AS/NZS 1429.1 excluding clauses 2.14, 3.3 to 3.9, Annex C;

AS/NZS 1972 excluding section 3 Cables in accordance with AS/NZS 1026, section 3 Cables in accordance with AS/NZS 1429.1 - exclusions as listed at AS/NZS 1429.1 section 4, clauses 5.5.10, 5.9.9 and 6.15.3;

AS/NZS 4026 excluding section 2 Cables in accordance with AS/NZS 1429.1 - exclusions as listed at AS/NZS 1429.1, section 3 Cables in accordance with AS/NZS 1026;

AS/NZS 2276.1 excluding Appendix B

Electrical safety of electrical cables, cords and conductors Ageing; Bending; Dimensions; Mass; Shrinkage; Tensile strength; Vertical flame propagation; Water absorption; Wrapping

AS/NZS 3808 excluding Acid and corrosive gas emission, Melt flow index, Carbon black content, Carbon black dispersion, Environmental stress crack resistance;

AS/NZS 1125;

AS/NZS 1660.1 excluding Metal plating tests of clause 4.1, clause 4.2 and clause 4.3;

AS/NZS 1660.2.1 excluding tests at low temperature for insulation and sheath of clause 2.3;

AS/NZS 1660.2.2;

AS/NZS 1660.2.3 excluding clause 2.5;

AS/NZS 1660.2.5;

AS/NZS 1660.3 excluding clauses 3.8 to 3.12, 3.14 and 3.15; 

AS/NZS 1660.5.6:2005;
AS/NZS IEC 60332.1.1;
AS/NZS IEC 60332.1.2;
AS/NZS IEC 60332.1.3;
AS/NZS 3191 excluding Appendix C;

AS/NZS 5000.1;

AS/NZS 5000.2;

AS/NZS 1429.1 excluding clauses 2.14, 3.3 to 3.9, Annex C;

AS/NZS 1972 excluding section 3 Cables in accordance with AS/NZS 1026, section 3 Cables in accordance with AS/NZS 1429.1 - exclusions as listed at AS/NZS 1429.1 section 4, clauses 5.5.10, 5.9.9 and 6.15.3;

AS/NZS 4026 excluding section 2 Cables in accordance with AS/NZS 1429.1 - exclusions as listed at AS/NZS 1429.1, section 3 Cables in accordance with AS/NZS 1026;

AS/NZS 2276.1 excluding Appendix B

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.