National Association of Testing Authorities, Australia
Scope of Accreditation
Civil Calibration Services Pty Limited
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dimensional metrology - Engineering equipment and precision instruments | Dial gauges; Electronic length gauges | Length measurements | Direct measurement against a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 2.9 μm from 0 mm to 25 mm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Force metrology - Force measuring and testing equipment | Compression and universal machines in compression | Force in compression | Comparison measurement with reference load cell | Calibration to Class A requirements of AS 2193 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including on site calibrations with Calibration and Measurement Capability of - 0.25% of reading above 0.5 kN to 100 kN | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Elastic force measuring devices | Force in compression | Comparison measurement with reference load cell; Gravimetric measurement with reference mass | Class A requirements of AS 2193 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including on site calibration of load cells Calibration of devices such as load measuring rings and load cells with digital displays for CBR and UCS machines in compressionwith Calibration and Measurement Capability of - 0.5% of reading from 0.05 kN to 0.5 kN | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Force metrology - Hardness standards and equipment | Rubber bases | Rubber hardness | Comparison with a reference standard | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Rubber hardness measurement With Calibration and Measurement Capability of - 1 IRHD from 86 IRHD to 94 IRHD | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Mass - Determination of mass and calibration of weighing devices | Industrial mass standards | Mass | Gravimetric measurement against reference mass | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration ad Measurement Capability of - 0.12 g from 100 g to 2 kg | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Industrial weighing devices; Laboratory weighing devices | Mass | Gravimetric measurement against reference mass | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including on site calibrations with Calibration and Measurement Capability of - 1 in 105 or 0.15 g (whichever is greater) from 100 g to 20 kg | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Vibration metrology - Vibration equipment | Vibrating tables | Displacement sensitivity; Frequency | Direct measurement by electrical input | Verification of vibrating tables and tools to the requirements of AS1289 5.5.1 TfNSW TS 02800.05 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 4.5% of reading from 30 Hz to 40 Hz | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Volume and density - Determination of density | Standard nuclear gauge density blocks | kg/m3 | Gravimetric | AS 1289.5.8.5 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Calibration of standard density blocks with Calibration and Measurement Capability of- 0.02% of reading from 1000 kg/m3 to 3000 kg/m3 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Volume and density - Nuclear density gauges | Nuclear moisture/density gauges | Density; Moisture | Comparison with a reference standard | AS1289.5.8.4, AS/NZS 2891.14.4 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Calibration of nuclear gauges using Type A density blocks for density and moisture in direct transmission and backscatter mode with Calibration and Measurement Capability of - By direct transmission 9 kg/m3 for density range of 1727 kg/m3 to 2713 kg/m3 By backscatter mode 30 kg/m3 for density in the range of 1727 kg/m3 to 2713 kg/m3 9 kg/m3 for water content in the range of 0 to 588 kg/m3 |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
4935
Site No.
4928
Print date