Scope of Accreditation
Centigrade Commissioning Testing Facility
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of air control equipment | Air conditioning and ventilation systems | Air pressure | Not applicable | AS 1807.10 (2000) | Mechanically ventilated health care enclosures, for the purpose of determining compliance with AS 1668.2 (Sections 5.3, 5.4, 5.5, 5.6, 5.9) |
Exhaust airflow rate | Not applicable | AS 1807.1 (2000) | Mechanically ventilated health care enclosures, for the purpose of determining compliance with AS 1668.2 (Sections 5.3, 5.4, 5.5, 5.6, 5.9) | ||
Integrity of HEPA filter installations | Not applicable | AS 1807.6 (2000), AS 1807.7 (2000) | Mechanically ventilated health care enclosures, for the purpose of determining compliance with AS 1668.2 (Sections 5.3, 5.4, 5.5, 5.6, 5.9) | ||
Biological safety cabinets | Illuminance | Not applicable | AS 1807 clause 4.5 | for compliance with: AS 2252.1, AS 2252.2 | |
Air velocity and uniformity of air velocity | Not applicable | AS 1807 clause 4.1 | for compliance with: AS 2252.2 | ||
Air barrier containment | Cold DOP | AS 1807 clause 4.9 | for compliance with: AS 2252.2 | ||
Integrity of HEPA filter installations | Cold DOP | AS 1807 clause 4.4 | for compliance with: AS 2252.1, AS 2252.2 | ||
Work zone integrity | Cold DOP | AS 1807 clause 4.3 | for compliance with: AS 2252.2 | ||
Inward air velocity | Not applicable | AS 1807 clause 4.8 | for compliance with: AS 2252.1, AS 2252.2 | ||
Ultraviolet intensity | Not applicable | AS 1807 clause 4.10 | for compliance with: AS 2252.1, AS 2252.2 | ||
Sound level | Not applicable | AS 1807 clause 4.7 | for compliance with: AS 2252.1, AS 2252.2 | ||
Clean rooms | Sound level | Not applicable | AS 1807.16 (2000) | ||
Integrity of HEPA filter installations | Cold DOP | AS ISO 14644.3 section 7, clauses B.7.2 & B.7.4, AS 1807.6 (2000), AS 1807.7 (2000) | |||
Air velocity and uniformity of air velocity | Not applicable | AS ISO 14644.3 Section 2, clauses B.2.2.2, B.2.2.5 and B.2.3.4, AS 1807.1 (2000) | |||
Air pressure | Not applicable | AS ISO 14644.3 section 1, clause B.1.2, AS 1807.10 (2000) | |||
Illuminance | Not applicable | AS 1807.15 (2000) | |||
Air flow direction and visualization | Not applicable | AS ISO 14644.3 section 3, clause B.3.3.4 | |||
Leakage | Cold DOP | AS ISO 14644.3 section 8, clause B.8.2.2 | |||
Particle count in work zone | Automatic particle counter | AS ISO 14644.1 Annex A, section 5, clause A.5 | |||
Clean workstations | Integrity of HEPA filter installations | Cold DOP | AS 1807 clause 4.4, AS 1807.6 (2000), AS 1807.7 (2000) | for compliance with: AS 2252.6 | |
Particle count in work zone | Automatic particle counter | AS ISO 14644.1 Annex A section 5, clause A.5 | for compliance with: AS 2252.6 | ||
Illuminance | Not applicable | AS 1807 clause 4.5, AS 1807.15 (2000) | for compliance with: AS 2252.6 | ||
Air velocity and uniformity of air velocity | Not applicable | AS 1807 clause 4.1, AS 1807.1 (2000) | for compliance with: AS 2252.6 | ||
Sound level | Not applicable | AS 1807 clause 4.7, AS 1807.20 (2000) | for compliance with: AS 2252.6 | ||
Work zone integrity | Cold DOP | AS 1807 clause 4.3 | for compliance with: AS 2252.6 | ||
Ultraviolet intensity | Not applicable | AS 1807 clause 4.10 | for compliance with: AS 2252.6 | ||
Cytotoxic drug safety cabinets | Work zone integrity | Cold DOP | AS 1807 clause 4.3 | for compliance with: AS 2252.5 | |
Ultraviolet intensity | Not applicable | AS 1807 clause 4.10 | for compliance with: AS 2252.5 | ||
Air velocity and uniformity of air velocity | Not applicable | AS 1807 clause 4.1 | for compliance with: AS 2252.5 | ||
Sound level | Not applicable | AS 1807 clause 4.7 | for compliance with: AS 2252.5 | ||
Particle count in work zone | Automatic particle counter | AS ISO 14644.1 Annex A, section 5 clause A.5 | for compliance with: AS 2252.5 | ||
Integrity of HEPA filter installations | Cold DOP | AS 1807 clause 4.4 | for compliance with: AS 2252.5 | ||
Air barrier containment | Cold DOP | AS 1807 clause 4.9 | for compliance with: AS 2252.5 | ||
Illuminance | Not applicable | AS 1807 clause 4.5 | for compliance with: AS 2252.5 | ||
Fume cupboards and recirculating fume cabinets | Illuminance | Not applicable | AS 1807.15 (2000) | For compliance with: AS/NZS 2243.8, AS/NZS 2243.9 | |
Extraction performance | Smoke visualisation | AS/NZS 2243.8 Appendix A, AS/NZS 2243.9 Appendix A | for compliance with: AS/NZS 2243.8, AS/NZS 2243.9 | ||
Extraction performance | Face velocity | AS/NZS 2243.8 Appendix B, AS/NZS 2243.9 Appendix B | for compliance with: AS/NZS 2243.8, AS/NZS 2243.9 | ||
Sound level | Not applicable | AS 1807.20 (2000) | For compliance with: AS/NZS 2243.8, AS/NZS 2243.9 | ||
Pharmaceutical isolators | Integrity of HEPA filter installations | Cold DOP | AS 1807 clause 4.4, AS 1807.6 (2000) AS 1807.7 (2000) | for compliance with: AS 4237 | |
Air velocity and uniformity of air velocity | Not applicable | AS 1807 clause 4.1, AS 1807.1 (2000) | for compliance with: AS 4237 | ||
Air pressure | Not applicable | AS ISO 14644.1 section1, clause B.1.2, AS 1807.10 (2000) | for compliance with: AS 4237 | ||
Particle count in work zone | Automatic particle counter | AS ISO 14644.1 Annex A, section 5, clause A.5 | for compliance with: AS 4273 |