Compliance Monitoring

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
Flow metrology - Flow measuring devices and systems Flow test stations Flow rate; Mass and energy; Volume (and nominal flow rate) To be determined

AS 3580.9.11 and AS 3580 9.12

 Particle mass calibration

BAM in the range 0 to 3000μg








Volumetric flow rate calibration
BAM in the range 0 to 20 L/min








Pressure transducer calibration
BAM in the range 500 to 1100 hPa








Temperature sensor calibration
BAM in the range 0 to 40ºC


















Capability

Particle mass calibration
With least uncertainty of measurement of -
48μg
Volumetric flow rate calibration
With least uncertainty of measurement of -
0.6%
Pressure transducer calibration

With least uncertainty of measurement of -
1 hPa 

Temperature sensor calibration
With least uncertainty of measurement of -
0.3ºC

ISO/IEC 17025 (2017)

Environment

Service Product Determinant Technique Procedure
Analysis for elements Air - Ambient Mercury Atomic fluorescence spectroscopy (AFS) - Cold vapour

in house method CMWI118

Analysis for industrial chemicals Air - Ambient Volatile organic compounds (VOCs) - Methane; Volatile organic compounds (VOCs) - Non-methane Flame ionisation detector (FID)

AS/NZS 3580.11.1 and in-house method CMWI79

Volatile organic compounds (VOCs) Flame ionisation detector (FID)

AS/NZS 3580.11.1 and in-house method CMWI124

Emissions - Industrial Nitrogen oxide Electrochemical gas analyser USEPA Method 7E and in-house method CMWI110
Sulfur dioxide UV fluorescence in-house method CMWI110
Carbon monoxide Electrochemical gas analyser USEPA Method 10 and in-house method CMWI110
Nitrogen - Oxides (NOx); Nitrogen dioxide Chemiluminescence in-house method CMWI78
Analysis for physical and chemical characteristics Air - Ambient Hydrogen sulfide UV fluorescence AS 3580.4.1 and in-house method CMWI10
Suspended particulate matter - PM10 High volume gravimetric AS/NZS 3580.9.6 and in-house method CMWI01
Nitric oxide; Nitrogen - Oxidised; Nitrogen dioxide Chemiluminescence

AS 3580.5.1 and in house method CMWI78

Suspended particulate matter - PM2.5 Tapered element oscillating microbalance (TEOM) AS/NZS 3580.9.13 and in-house method CMWI02
Hydrogen fluoride Ion selective electrode (ISE)

AS/NZS 3580 13.2 and in house method CMWI80

Suspended particulate matter - PM2.5 Beta attenuation monitors AS/NZS 3580.9.12 and in-house method CMWI86
Suspended particulate matter - PM2.5 High volume gravimetric AS/NZS 3580.9.14 and in-house method CMWI01
Suspended particulate matter - PM2.5 Low volume gravimetric AS 3580.9.10 and in-house method CMWI01
Suspended particulate matter - PM10 Low volume gravimetric AS 3580.9.9 and in-house method CMWI01
Ozone UV-vis spectrophotometry

AS 3580.6.1 and in-house method CMWI67

Carbon monoxide Nondispersive infrared (NDIR)

AS 3580.7.1 and in house method CMWI81

Suspended particulate matter - PM10 Beta attenuation monitors

AS/NZS 3580.9.11 and in house method CMWI86

Suspended particulate matter - PM10 Tapered element oscillating microbalance (TEOM) AS 3580.9.8 and in-house method CMWI02
Suspended particulate matter - Total High volume gravimetric AS/NZS 3580.9.3 and in-house methods CMWI01
Sulfur dioxide UV fluorescence

AS 3580.4.1 and in-house method CMWI10

Atmospheric dust fall Ash; Combustible matter; Solids - Insoluble; Solids - Soluble; Solids - Total Gravimetric

AS/NZS 3580 10 1 and in house method CMWI30

Emissions - Industrial Carbon monoxide Nondispersive infrared (NDIR) USEPA Method 10, and in-house method CMWI110
Moisture Gravimetric; Volumetric USEPA method 4
Hydrogen sulfide Fluorescence

 in house method CMWI110

Hydrogen sulfide UV fluorescence in-house method CMWI110
Emissions - Stack Sulfur dioxide Gas analyser USEPA Method 6C and in-house method CMWI110
Carbon dioxide (CO2); Oxygen Gas analyser USEPA Method 3A and in-house method CMWI110
Emissions - Stack; Emissions - Stationary sources Moisture Volumetric Emission Measurement Center Approved Alternate Method ALT-008 and in-house method CMWI109
Ground waters; Industrial waters - Treated; Irrigation and stock waters; Potable waters; Saline waters; Sewage; Steam-raising waters; Surface waters; Trade wastes Turbidity Nephelometry in-house method CMWI49
Dissolved oxygen (DO) Membrane electrode in-house method CMWI49
pH Electrometric in-house method CMWI49
Conductivity Electrometric

in-house method CMWI49

Stack gases Flow rate; Velocity Classical; Pitot USEPA Method 2 and in-house method CMWI111
Analysis of dust Air Volume measurement Sampling flow rate and duration measurement AS 2985, AS 3640 and in-house method CMWI01
Membrane filters Dust - Respirable Gravimetric AS 2985 and in-house method CMWI01
Dust - Inhalable Gravimetric

AS 3640 and in-house method CMWI01

Analysis of the workplace environment and hazards for metals and metal compounds Air - Ambient Volume measurement Sampling flow rate and duration measurement NIOSH 7300
Counting of asbestos, mineral fibres (including synthetic) and organic fibres Air Volume measurement Sampling flow rate and duration measurement
Meteorological monitoring Atmosphere Pressure Barometer

AS/NZS 3580.14 and in house method CMWI32

Temperature Temperature probe AS/NZS 3580.14 and in-house method CMWI32
Solar radiation Pyranometer AS/NZS 3580.14 and in-house method CMWI32
Relative humidity (RH) Hygrometer AS/NZS 3580.14 and in-house method CMWI32
Rainfall Rainfall gauge AS/NZS 3580.14 and in-house method CMWI32
Wind direction; Wind speed - Horizontal Ultrasonic anemometer AS/NZS 3580.14 and in-house method CMWI32
Sample collection Air - Ambient Not applicable Siting of air monitoring equipment

AS 3580.1.1

Not applicable Passive diffusive

in-house method CMWI95

Ground waters; Potable waters; Sewage; Surface waters; Waste waters Not applicable Automated; Grab; Pump AS/NZS 5667.1, AS/NZS 5667.2, AS/NZS 5667.3, AS/NZS 5667.4, AS/NZS 5667.5, AS/NZS 5667.6, AS/NZS 5667.10, AS 5667.11, in-house method CMWI51, in-house method CMWI53, in-house method CMWI92 and in-house method CMWI93
Sample collection - Stack and emissions sampling Emissions - Industrial Volatile organic compounds (VOCs) Adsorption tube  USEPA Method 18 and in-house method CMWI115

Moisture Impinger Emission Measurement Center Approved Alternative Method ALT-008 and in-house CMWI109
Emissions - Stack Sampling position - Selection Not applicable AS 4323.1
USEPA Method 1
Carbon dioxide (CO2); Carbon monoxide; Nitrogen - Oxides (NOx); Oxygen; Sulfur dioxide Continuous flow analyser (CFA) USEPA Method 3 A, USEPA Method 6C, in-house method CMWI100 and in-house method CMWI110

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.