Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow metrology - Flow measuring devices and systems | Flow test stations | Flow rate; Mass and energy; Volume (and nominal flow rate) | To be determined |
AS 3580.9.11 and AS 3580 9.12 |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability
|
ISO/IEC 17025 (2017)
Environment
Service | Product | Determinant | Technique | Procedure |
---|---|---|---|---|
Analysis for elements | Air - Ambient | Mercury | Atomic fluorescence spectroscopy (AFS) - Cold vapour |
in house method CMWI118 |
Analysis for industrial chemicals | Air - Ambient | Volatile organic compounds (VOCs) | Flame ionisation detector (FID) |
AS/NZS 3580.11.1 and in-house method CMWI79 |
Volatile organic compounds (VOCs) - Methane; Volatile organic compounds (VOCs) - Non-methane | Flame ionisation detector (FID) |
AS/NZS 3580.11.1 and in-house method CMWI79 |
||
Emissions - Industrial | Carbon monoxide | Electrochemical gas analyser | USEPA Method 10 and in-house method CMW110 | |
Nitrogen - Oxides (NOx); Nitrogen dioxide | Chemiluminescence | in-house method CMW178 | ||
Sulfur dioxide | UV fluorescence | in-house method CMW110 | ||
Nitrogen oxide | Electrochemical gas analyser | USEPA Method 7E and in-house method CMW110 | ||
Analysis for physical and chemical characteristics | Air - Ambient | Suspended particulate matter - PM2.5 | Low volume gravimetric | AS 3580.9.10 and in-house method CMW101 |
Hydrogen fluoride | Ion selective electrode (ISE) |
AS/NZS 3580 13.2 and in house method CMWI80 |
||
Suspended particulate matter - PM2.5 | High volume gravimetric | AS/NZS 3580.9.14 and in-house method CMW101 | ||
Nitric oxide; Nitrogen - Oxidised; Nitrogen dioxide | Chemiluminescence |
AS 3580.5.1 and in house method CMW178 |
||
Suspended particulate matter - PM10 | Tapered element oscillating microbalance (TEOM) | AS 3580.9.8 and in-house method CMW102 | ||
Suspended particulate matter - PM2.5 | Beta attenuation monitors | AS/NZS 3580.9.12 and in-house method CMW186 | ||
Suspended particulate matter - PM10 | Low volume gravimetric | AS 3580.9.9 and in-house method CMW101 | ||
Hydrogen sulfide | UV fluorescence | AS 3580.4.1 and in-house method CMW110 | ||
Suspended particulate matter - PM2.5 | Tapered element oscillating microbalance (TEOM) | AS/NZS 3580.9.13 and in-house method CMW102 | ||
Carbon monoxide | Nondispersive infrared (NDIR) |
AS 3580.7.1 and in house method CMWI81 |
||
Suspended particulate matter - PM10 | Beta attenuation monitors |
AS/NZS 3580.9.11 and in house method CMW186 |
||
Suspended particulate matter - PM10 | High volume gravimetric | AS/NZS 3580.9.6 and in-house method CMW101 | ||
Suspended particulate matter - Total | High volume gravimetric | AS/NZS 3580.9.3 and in-house methods CMW101 | ||
Sulfur dioxide | UV fluorescence |
AS 3580.4.1 and In house method CMWI10 |
||
Ozone | UV-vis spectrophotometry |
AS 3580.6.1 and in-house method CMWI67 |
||
Atmospheric dust fall | Ash; Combustible matter; Solids - Insoluble; Solids - Soluble; Solids - Total | Gravimetric |
AS/NZS 3580 10 1 and in house method CMWI30 |
|
Emissions - Industrial | Carbon monoxide | Nondispersive infrared (NDIR) | in-house method CMW101 | |
Hydrogen sulfide | Fluorescence |
in house method CMW110 |
||
Moisture | Gravimetric; Volumetric |
USEPA method 4 |
||
Hydrogen sulfide | UV fluorescence | in-house method CMW110 | ||
Emissions - Stack | Sulfur dioxide | Gas analyser | USEPA Method 6C and in-house method CMWI110 | |
Carbon dioxide (CO2); Oxygen | Gas analyser | USEPA Method 3A and in-house method CMWI110 | ||
Emissions - Stack; Emissions - Stationary sources | Moisture | Volumetric | Emission Measurement Center Approved Alternate Method ALT-008 and in-house method CMWI109 | |
Ground waters; Industrial waters - Treated; Irrigation and stock waters; Saline waters; Sewage; Steam-raising waters; Surface waters; Trade wastes | pH | Electrometric | in-house method CMW149 | |
Turbidity | Nephelometry | in-house method CMW149 | ||
Dissolved oxygen (DO) | Membrane electrode | in-house method CMW149 | ||
Conductivity | Electrometric |
In house method CMWI49 |
||
Stack gases | Flow rate; Velocity | Classical; Pitot | USEPA Method 2 and in-house methpod CMWI111 | |
Analysis of dust | Air | Volume measurement | Sampling flow rate and duration measurement | AS 2985, AS 3640 and in-house method CMW101 |
Membrane filters | Dust - Respirable | Gravimetric | AS 2985 and in-house method CMW101 | |
Dust - Inhalable | Gravimetric |
AS 3640 and in-house method CMWI01 |
||
Analysis of the workplace environment and hazards for metals and metal compounds | Air - Ambient | Volume measurement | Sampling flow rate and duration measurement | NIOSH 7300 |
Counting of asbestos, mineral fibres (including synthetic) and organic fibres | Air | Volume measurement | Sampling flow rate and duration measurement | |
Meteorological monitoring | Atmosphere | Temperature | Temperature probe | AS/NZS 3580.14 and in-house method CMW132 |
Relative humidity (RH) | Hygrometer | AS/NZS 3580.14 and in-house method CMW132 | ||
Pressure | Barometer |
AS/NZS 3580.14 and in house method CMW132 |
||
Wind direction; Wind speed - Horizontal | Ultrasonic anemometer | AS/NZS 3580.14 and in-house method CMW132 | ||
Solar radiation | Pyranometer | AS/NZS 3580.14 and in-house method CMW132 | ||
Rainfall | Rainfall gauge | AS/NZS 3580.14 and in-house method CMW132 | ||
Sample collection | Air - Ambient | Not applicable | Siting of air monitoring equipment |
AS 3580.1.1 |
Not applicable | Passive diffusive |
in-house method CMWI95 |
||
Ground waters; Sewage; Surface waters; Waste waters | Not applicable | Automated; Grab; Pump | AS/NZS 5667.1, AS/NZS 5667.2, AS/NZS 5667.3, AS/NZS 5667.4, AS/NZS 5667.5, AS/NZS 5667.6, AS/NZS 5667.10, AS 5667.11, in-house method CMW151, in-house method CMW153, in-house method CMW192 and in-house method 193 | |
Sample collection - Stack and emissions sampling | Emissions - Industrial | Moisture | Impinger | Emission Measurement Center Approved Alternative Method ALT-008 and in-house CMWI109 |
Volatile organic compounds (VOCs) | Adsorption tube |
USEPA Method 18 and in-house method CMW1115 |
||
Emissions - Stack | Carbon dioxide (CO2); Carbon monoxide; Nitrogen - Oxides (NOx); Oxygen; Sulfur dioxide | Continuous flow analyser (CFA) | USEPA Method 3 A, USEPA Method 6C, in-house method CMW1100 and in-house emthod CMW1100 |
ISO/IEC 17025 (2017)
Food and Beverage
Service | Product | Determinant | Technique | Procedure |
---|---|---|---|---|
Analysis of physical and nutritional characteristics | Waters for potable and domestic purposes | pH | Electrometric | in-house method CMW149 |
Turbidity | Nephelometry | in-house method CMW149 | ||
Dissolved oxygen (DO) | Electrometric | in-house CMW149 | ||
Conductivity | Electrometric |
in house method CMWI49 |
||
Sample collection | Waters for potable and domestic purposes | Not applicable | Automated; Grab; Pump | AS/NZS 5667.1, AS/NZS 5667.2, AS/NZS 5667.3, AS/NZS 5667.4, AS/NZS 5667.5, AS/NZS 5667.6, AS/NZS 5667.10, AS/NZS 5667.11, in-house method CMW151, in-house method CMW153, in-house method CMW192 and in-house method CMW193 |