National Association of Testing Authorities, Australia
Scope of Accreditation
STA Consulting Engineers
Site
Eight Mile Plains Laboratory
Accreditation No.
3787
Site No.
3780
Date of Accreditation
13 Jul 1992
Address
Freeway Office Park, Building 3, 2728 Logan Road
Eight Mile Plains, QLD 4113
Australia
Contact
Availability
Services not available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of geotechnical and civil construction material - Soil classification | Soils | Linear shrinkage | Not applicable | AS 1289.3.4.1 | |
Plastic limit | Not applicable | AS 1289.3.2.1 | |||
Liquid limit | Casagrande one point | AS 1289.3.1.2 | |||
Plasticity index | Casagrande | AS 1289.3.3.1 | |||
Liquid limit | Casagrande four point | AS 1289.3.1.1 | |||
Moisture content | Drying oven | AS 1289.2.1.1 | |||
Evaluation of geotechnical and civil construction material - Soil in situ penetration | Soils | Penetration in situ | Dynamic cone | AS 1289.6.3.2 | |
Evaluation of geotechnical and civil construction material - Soil pre-treatment | Soils | Soil pre-treatment | Not applicable | AS 1289.1.1 | |
Evaluation of geotechnical and civil construction material - Soil reactivity | Soils | Reactivity | Shrink/swell | AS 1289.7.1.1 | |
Sample collection | Soils | Not applicable | Disturbed soil sampling in situ | AS 1289.1.2.1 |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
3787
Site No.
3780
Print date