National Association of Testing Authorities, Australia
Scope of Accreditation
Environment Agency - Abu Dhabi (EAD)
Site
Environmental Monitoring and Analysis Division – Abu Dhabi
Accreditation No.
19099
Site No.
21539
Date of Accreditation
28 Nov 2013
Address
Envirozone L.L.C, M-41 Workshop 2, Industrial City Abu Dhabi (ICAD), Mussafah
0
United Arab Emirates
Contact
Availability
Services not available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
| Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Chemical metrology - Gas analysers | Gas analysers | Concentration | Direct measurement by certified reference material |
in-house methods EAD-EQ-EMA-11,EAD-EQ-EMA-12, EAD-EQ-EMA-14, EAD-EQ-EMA-15, EAD-EQ-EMA-16, EAD-EQ-EMA-31, EAD-EQ-EMA-42, EAD-EQ-EMA-72, EAD-EQ-EMA-PM10 and manufacturer's instructions |
CO : IR, 0 - 50 ppm H2S : Fluorescence, 0 - 500 ppb NO/NOx : Chemiluminescence, 0 - 500 ppb SO2: Fluorescence, 0 - 500 ppb |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Capability With calibration and measurement capability - Benzene With least uncertainties of -1ppb or 5% of reading (whichever is greater) using in-house method EAD-EQ-EMA-72 CO : IR With least uncertainties of - 0.7 ppm or 7 % of reading (whichever is greater) using in-house method EAD-EQ-EMA-12 and EAD-EQ-EMA-31 H2S : Fluorescence With least uncertainties of - 5 ppb or 5 % of reading (whichever is greater) using in-house methods EAD-EQ-EMA-11 and EAD-EQ-EMA-14 NO/NOx : Chemiluminescence With least uncertainties of measurement of - 8 ppb or 8 % of reading (whichever is greater) using in-house methods EAD-EQ-EMA-15 and EAD-EQ-EMA-16 Ozone (O3):With least uncertainties of - 5ppb or 5% of reading (whichever is greater) using in-house method EAD-EQ-EMA-42 SO2: Fluorescence With least uncertainties of measurement of - 5 ppb or 5 % of reading (whichever is greater) using in-house methods EAD-EQ-EMA-11 and EAD-EQ-EMA-14 PM2.5, PM10: beta attenuation monitor 0-1000µg/M3With least uncertainties of measurement of – 18% of reading using in-house EAD-EQ-EMA-PM10 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The only data displayed is that deemed relevant and necessary for the clear description of the Activities and Services covered by the Scope of Accreditation (SoA).
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
The Product column may also describe an Item or Material.
The Limitations column may also describe the Range.
Accreditation No.
19099
Site No.
21539
Print date
27 Aug 2026