Franklin Offshore Australia Pty Ltd

Site

Henderson Laboratory

Accreditation No.

3073

Site No.

3066

Date of Accreditation

15 Jan 1991

Address

7 Possner Way
Henderson, WA 6166
Australia

franklinoffshore.com.au

Contact

Mr Adrian Kirkpatrick P: +61 (08) 94106000

Availability

Services available to external clients

Scope of Accreditation

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of geometric properties of structures and equipment Equipment modules; Structures and assemblies Centre of gravity Single and multiple compression load cells

In-house procedure WIWS-009

40 to 16000 kN

Structures and assemblies Weight Single and multiple compression load cells; Single and multiple suspension using tension load cells

In-house procedure WIWS-040, In-house procedure WIWS-041

2 to 16000 kN

Evaluation of load generating lifting appliances Cranes; Gantries and monorails Proof load Not applicable

In-house procedure WIWS-045

4 to 6000 kN

Jibs and suspension equipment; Serial and lever hoists Breaking load; Proof load Not applicable

AS 1418.2, AS 2741, AS 4991, Marine Orders Part 32 Appendix 5 Section 4,

In-house procedure WIWS 022

2 to 12000 kN including on-site testing (proof load)

Evaluation of load handling, rigging and tensioning systems Anchorages and supports for industrial fall arrest systems Extension; Proof load Not applicable

AS 2317, AS 3776, AS 3777,

In-house procedure WIWS 024

2 to 12000 kN including on-site testing (proof load)

Chain Breaking load; Extension; Proof load Not applicable

AS 2321, AS 3776.1, AS 4344,

In-house procedure WIWS 016, In-house procedure WIWS 020

2 to 12000 kN including on-site testing (proof load)

Chain and lever blocks; Lifting and spreader beams; Trolleys Breaking load; Extension; Proof load Not applicable

AS 1418.2, AS 2741, AS 4991, Marine Orders Part 32 Appendix 5 Section 4,

In-house procedure WIWS 022

2 to 12000 kN including on-site testing (proof load)

Chain slings Breaking load; Extension; Proof load Not applicable

AS 3775.1, AS 3775.2, in-house procedure WIWS 005

2 to 12000 kN including on-site testing (proof load)

Containers; Nets (for unloading cargo); Pallets Proof loadNULL Not applicable

Marine Orders 32 and 44, 

Petroleum Act - Schedule Specific Requirements as to Offshore Petrol Exploration and Production 1990, 

In-house procedure WIWS 011

2 to 2500 kN including on-site testing

Fibre rope Breaking load; Extension; Proof load Not applicable

AS 1380:1998,

In-house procedure WIWS 014

2 to 12000 kN including on-site testing (proof load)

Fibre rope slings Breaking load; Extension; Proof load Not applicable

AS 1380:1998,

In-house procedure WIWS 023

2 to 12000 kN including on-site testing (proof load)

Padeyes; Shackles; Sheave blocks Breaking load; Extension; Proof load Not applicable

AS 2076, AS 2089, AS 2317, AS 2318, AS 2319, AS 2740, AS 2741, AS 2759, AS 3637.5, AS 3776, AS 3777, AS 4991, 

Marine Orders Part 32 Appendix 5 Section 4, 

In-house procedures WIWS 029 and 033

2 to 12000 kN including on-site testing (proof load)

Synthetic fibre roundslings Proof load Not applicable

AS 4497.1,

In-house procedure WIWS 023

2 to 12000 kN including on-site testing

Synthetic webbing flat slings Breaking load; Extension; Proof load Not applicable

AS 1353.1

In-house procedure WIWS 023

2 to 12000 kN including on-site testing (proof load)

Wire rope Breaking load; Extension; Proof load Not applicable

AS 2759, AS 3569

2 to 12000 kN including on-site testing (proof load)

Wire rope slings Breaking load; Extension; Proof load Not applicable

AS 1666.1, AS 1666.2, AS 2759, AS 3569,

In-house procedure WIWS 001

2 to 12000 kN including on-site testing (proof load)

ISO/IEC 17025 (2017)

Manufactured Goods

Service Product Determinant Technique Procedure
Mechanical performance evaluation of ladders, racks, scaffolds and supports Storage rack systems Load carrying capacity Not applicable

In-house procedure WIWS 011

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.