IPD Group Ltd

Site

IPD Services (Bendigo)

Accreditation No.

20292

Site No.

15952

Date of Accreditation

01 Jun 2017

Address

10 Maynard Drive
Epsom, VIC 3551
Australia

ipd.com.au

Contact

Mr Jeremy McGuckian P: +61 (03) 54456222

Availability

Services available to external clients

Scope of Accreditation

IPD Services (Bendigo)

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations

Suspended

DC and low frequency electrical metrology - Electrical measurement and test equipment
Ammeters; Current clamps; Data recorders; Digital multimeters (DMM) AC current Comparison with a reference standard

0.25 μA to 1000 A at 50 Hz

Capability

With a Calibration and Measurement Capability of -

0.5% reading + 0.25 μA up to 0.33 mA
0.4% reading + 0.3 μA from 0.33 mA to 3.3 mA
0.36% reading + 3 μA from 3.3 mA to 33 mA
0.36% reading + 30 μA from 33 mA to 330 mA

0.4% reading + 300 μA from 330 mA to 2.2 A
0.24% reading + 2 mA from 2.2 A to 11 A
0.8% reading from 11 A to 100 A
2.0% reading from 100 A to 1000 A

Ammeters; Current clamps; Digital multimeters (DMM) DC current Comparison with a reference standard

0.05 μA to 1000 A

Capability

With a Calibration and Measurement Capability of -
0.052% reading + 0.05 μA up to 3.3 mA
0.04% reading + 0.25 μA from 3.3 mA to 33 mA
0.04% reading + 3.3 μA from 33 mA to 330 mA
0.12% reading + 44 μA from 330 mA to 2.2 A
0.24% reading + 330 μA from 2.2 A to 11 A
0.8% reading from 11 A to 100 A
2.0% reading from 100 A to 1000 A

Data recorders; Digital multimeters (DMM); Voltmeters AC voltage Comparison with a reference standard

45 Hz to 10 kHz
20 μV to 1020 V

Capability

With a Calibration and Measurement Capability of -
0.6% reading + 20 μV from 1 to 33 mV
0.2% reading + 20 μV from 33 to 330 mV
0.12% reading + 60 μV from 0.330 mV to 3.3 V
0.16% reading + 600 μV from 3.3 to 33 V
0.2% reading + 6.6 mV from 33 to 330 V
0.2% reading + 80 mV from 330 to 1020 V

Digital multimeters (DMM); Ohm meters Resistance Comparison with a reference standard

Capability

With a Calibration and Measurement Capability of -
0.048% reading + 0.008 Ω from 0 to 11 Ω
0.048% reading + 0.015 Ω from 11 to 33 Ω
0.036% reading + 0.015 Ω from 33 to 330 Ω
0.036% reading + 0.06 Ω from 330 Ω to 3.3 kΩ
0.036% reading + 0.6 Ω from 3.3 to 33 kΩ
0.048% reading + 6 Ω from 33 to 330 kΩ
0.06% reading + 55 Ω from 330 kΩ to 3.3 MΩ
0.4% reading + 550 Ω from 3.3 to 33 MΩ
2.0% reading + 5.5 kΩ from 33 to 110 MΩ
2.0% reading + 16.5 kΩ from 110 to 330 MΩ

Digital multimeters (DMM); Voltmeters DC voltage Comparison with a reference standard

3 μV to 1020 V

Capability

With a Calibration and Measurement Capability of -
0.024% reading + 3 μV up to 330 mV
0.02% reading + 5 μV from 300 mV to 3 V
0.02% reading + 50 μV from 3 V to 33 V
0.022% reading + 0.5 mV from 33 V to 330 V
0.022% reading +1.5 mV from 330 V to 1020 V

Insulation resistance test equipment Resistance Comparison with a reference standard

Capability

with Calibration and Measurement Capability of -
0.048% reading + 0.008 Ω from 0 to 11 Ω up to 500 V dc
0.048% reading + 0.015 Ω from 11 to 33 Ω  up to 500 V dc
0.036% reading + 0.015 Ω from 33 to 330 Ω  up to 500 V dc
0.036% reading + 0.06 Ω from 330 Ω to 3.3 kΩ  up to 500 V dc
0.036% reading + 0.6 Ω from 3.3 to 33 kΩ  up to 500 V dc
0.048% reading + 6 Ω from 33 to 330 kΩ  up to 500 V dc
0.06% reading + 55 Ω from 330 kΩ to 3.3 MΩ  up to 500 V dc
0.4% reading + 550 Ω from 3.3 to 33 MΩ  up to 500 V dc
2.0% reading + 5.5 kΩ from 33 to 100 MΩ  up to 500 V dc

Suspended

Time and frequency metrology - Frequency, time and waveform measuring equipment
Counters; Frequency analysers; Frequency meters; Waveform measuring instruments Frequency Measurement against reference standard

0.01 Hz to 2 MHz

Capability

With a Calibration and Measurement Capability of -
100 μHz/Hz + 1 mHz from 0.01 Hz to 10 kHz
100 μHz/Hz + 15 mHz above 10 kHz to 2 MHz
Waveform measuring instruments Current Measurement against reference standard; To be determined 0.25 μA to 1000 A

Capability

With a Calibration and Measurement Capability of - 

A, C. Current input at 50 Hz
 0.5% reading + 0.25 μA up to 0.33 mA
 0.4% reading  + 0.3 μA from 0.33 mA to 3.3 mA
 0.36% reading + 3 μA from 3.3 mA to 33 mA
 0.36% reading + 30 μA from 33 mA to 330 mA
 0.4% reading + 300 μA from 330 mA to 2.2 A
 0.24% reading + 2 mA from 2.2 A to 11 A
 0.8% reading from 11 A to 100 A
 2.0% reading from 100 A to 1000 A

Voltage Measurement against reference standard 1 mV to 1020 V

Capability

With a Calibration and Measurement Capability of -
A.C. Voltage input at 45 Hz to 10 kHz
0.6% reading + 20 μV from 1 mV  to 33 mV
 0.2% reading + 20 μV from 33 to 330 mV
 0.12% reading + 60 μV from 0.330 mV to 3.3 V
 0.16% reading + 600 μV from 3.3 to 33 V
 0.2% reading + 6.6 mV from 33 to 330 V
 0.2% reading + 80 mV from 330 to 1020 V

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.