Light Science Pty Ltd

Site

Light Science Photometric, Electrical and Thermal Testing Laboratory

Accreditation No.

20592

Site No.

24686

Date of Accreditation

21 Apr 2020

Address

Suite 3, 82 Bathurst Street
Liverpool, NSW 2170
Australia

lightscience.com.au

Contact

Mr Vipul Gajjar P: +61 (02) 81078811

Availability

Services available to external clients

Scope of Accreditation

Light Science Photometric, Electrical and Thermal Testing Laboratory

ISO/IEC 17025 (2017)

Manufactured Goods

Service Product Determinant Technique Procedure Limitations
Evaluation of consumer and industrial lighting, optical systems and eyewear Emergency evacuation lighting and exit luminaires Chromaticity; Classification of emergency luminaires; Current; Distribution of luminous intensity; Luminance; Luminous flux; Power AC and DC; Voltage Direct measurement by goniophotometer; Direct measurement using a reference meter AS 1680.3
AS 2293.1 Appendix E and Appendix F;
AS 2293.3 Appendix C
CIE 121;
IES LM-79;




Current; Power AC and DC; Power factor; Temperature; Temperature - In-situ; Voltage Direct measurement using a reference meter AS/NZS 60598.1 Clause 12.4;
IEC 60598.1 Clause 12.4;
IES LM-84 Annex A;
AS 2293.3 Appendix D

Emergency evacuation lighting and exit luminaires; General lighting - LED and other solid state lamps; LED and other solid state lighting sources; Lighting for roads and public spaces Chromaticity; Colour; Colour rendering indices; Colour spacial uniformity; Correlated colour temperature; Cyanosis observation index; Melanopic ratio (melanopic factor); Spectral irradiance Direct measurement using a reference meter; Measurement using a spectroradiometer and software integration AS/NZS 1680.2.5;
CIE 13.3
CIE 018
CIE 121;
IES LM-79;
IES TM-30
International WELL Building Standard
Current; Endurance; Lumen maintenance; Power AC and DC; Power factor; Temperature; Temperature - In-situ; Voltage Direct measurement using a reference meter AS/NZS 60598.1 Clause 12 (excluding subclauses 12.5, 12.6 and 12.7);
IEC 60598-1 Clause 12 (excluding subclauses 12.5, 12.6 and 12.7);
AS/NZS 60598.1:2003 Clause 12 (excluding subclauses 12.5, 12.6 and 12.7);
AS/NZS 60598.2.2 Clauses 2.13 and 2.14, including ingress test for classifications CA 90, CA 135, IC, IC-4 only;
AS/NZS 60598.2.2:2001 Clause 2.12 incorporating New Zealand only Amendment A
IES TM-21;
IES LM-84 Annex A;
 ENERGY STAR TM-21 Calculator
General lighting - LED and other solid state lamps; LED and other solid state lighting sources Current; Distribution of luminous intensity; Lamp circuit power (LCP); Lamp efficacy; Light output; Luminous flux; Power AC and DC; Power factor; Voltage Direct measurement by goniophotometer; Direct measurement using a reference meter AEMO Unmetered Load Guideline-Determination of Device Load and Annual Energy Consumption for Unmetered Load Devices Section 7 Part 11;
CIE 121;
IES LM-79;



Lighting for roads and public spaces Discomfort Glare Index (GDI); Distribution of luminous intensity; Limitation of luminous intensity Direct measurement by goniophotometer CIE 121;
IES LM-79;
AS/NZS 1158.1.1;
AS/NZS 1158.2;
AS/NZS 1158.3.1;
SA/SNZ TS 1158.6;

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.