Bullivants Pty Limited

Site

Melbourne Laboratory

Accreditation No.

369

Site No.

362

Date of Accreditation

24 Nov 1961

Address

114 - 116 Boundary Road
Braeside, VIC 3195
Australia

bullivants.com

Contact

Mr Thomas Mate P: +61 0436388353

Availability

Services conditionally available to external clients

Scope of Accreditation

Melbourne Laboratory

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of load generating lifting appliances Gantries and monorails Proof load Not applicable

AS 1418.2, AS 1418.18

1 to 1000 kN

Jibs and suspension equipment Proof load Not applicable

AS 4991

1 to 3000 kN

Serial and lever hoists Operational load Not applicable AS 1418.2 1 to 3000 kN
Evaluation of load handling, rigging and tensioning systems Anchorages and supports for industrial fall arrest systems Proof load Not applicable

AS/NZS 1891.4 Sections 3.1.1,3.1.2

1 to 3000 kN; on-site tests from 1 to 300 kN

C-hooks Proof load Not applicable AS 4991 1 to 3000 kN; on-site tests from 1 to 300 kN
Chain slings Proof load Not applicable

AS 3775.1; AS 3775.2

1 to 3000 kN; on-site tests from 1 to 300 kN

Containers; Fittings Proof load Not applicable

AS 2076, AS 3776, AS 4991.

1 to 3000 kN; on-site tests from 1 to 300 kN

Eye bolts; Eye hooks Proof load Not applicable AS 2317.1
Fibre rope slings Proof load Not applicable

AS 1380.1 (1998)

1 to 3000 kN; on-site tests from 1 to 300 kN

Lifting clutches for concrete elements Proof load Not applicable

AS 3850.1

1 to 3000 kN; on-site tests from 1 to 300 kN

Rigging screws and turnbuckles Proof load Not applicable AS 2319 1 to 3000 kN; on-site tests from 1 to 300 kN
Shackles Proof load Not applicable AS 2741 1 to 3000 kN; on site tests 1 to 300kN
Shank hooks Proof load Not applicable AS 3777 1 to 3000 kN; on-site tests from 1 to 300 kN
Sheave blocks Proof load Not applicable AS 2089 1 to 3000 kN; on-site tests from 1 to 300 kN
Sockets Proof load Not applicable AS 2740 1 to 3000 kN; on-site tests from 1 to 300 kN
Swivels Proof load Not applicable AS 2318 1 to 3000 kN; on-site tests from 1 to 300 kN
Synthetic fibre roundslings Proof load Not applicable

AS 4497

1 to 3000 kN; on-site tests from 1 to 300 kN

Synthetic webbing flat slings Proof load Not applicable

AS 1353.1

1 to 3000 kN; on-site tests from 1 to 300 kN

Wire rope Proof load Not applicable

AS 3569

1 to 3000 kN; on-site tests from 1 to 300 kN

Wire rope slings Proof load Not applicable

AS 1666.1; AS 1666.2; AS 2759; AS 3569

1 to 3000 kN; on-site tests from 1 to 300 kN

Non-destructive testing (NDT) - Electromagnetic testing - Specialised - Magnetic flux leakage (MFL) Wire rope Corrosion; Detection of broken wires; Fretting; Mechanical damage and wear Not applicable
Non-destructive testing (NDT) - Visual testing - During service life Wire rope Detection of broken wires; Fretting; Mechanical damage and wear Visual testing

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.