Bullivants Pty Limited

Site

Melbourne Laboratory

Accreditation No.

369

Site No.

362

Date of Accreditation

24 Nov 1961

Address

114 - 116 Boundary Road
Braeside, VIC 3195
Australia

bullivants.com

Contact

Mr Thomas Mate P: +61 0436388353

Availability

Services conditionally available to external clients

Scope of Accreditation

Melbourne Laboratory

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of load generating lifting appliances Gantries and monorails Proof load Not applicable

AS 1418.2, AS 1418.18

1 to 1000 kN

Jibs and suspension equipment Proof load Not applicable

AS 4991

1 to 3000 kN

Serial and lever hoists Operational load Not applicable AS 1418.2 1 to 3000 kN
Evaluation of load handling, rigging and tensioning systems Anchorages and supports for industrial fall arrest systems Proof load Not applicable

AS/NZS 1891.4 Sections 3.1.1,3.1.2

1 to 3000 kN; on-site tests from 1 to 300 kN

C-hooks Proof load Not applicable AS 4991 1 to 3000 kN; on-site tests from 1 to 300 kN
Chain slings Proof load Not applicable

AS 3775.1; AS 3775.2

1 to 3000 kN; on-site tests from 1 to 300 kN

Containers; Fittings Proof load Not applicable

AS 2076, AS 3776, AS 4991.

1 to 3000 kN; on-site tests from 1 to 300 kN

Eye bolts; Eye hooks Proof load Not applicable AS 2317.1
Fibre rope slings Proof load Not applicable

AS 18264

1 to 3000 kN; on-site tests from 1 to 300 kN

Lifting clutches for concrete elements Proof load Not applicable

AS 3850.1

1 to 3000 kN; on-site tests from 1 to 300 kN

Rigging screws and turnbuckles Proof load Not applicable AS 2319 1 to 3000 kN; on-site tests from 1 to 300 kN
Shackles Proof load Not applicable AS 2741 1 to 3000 kN; on site tests 1 to 300kN
Shank hooks Proof load Not applicable AS 3777 1 to 3000 kN; on-site tests from 1 to 300 kN
Sheave blocks Proof load Not applicable AS 2089 1 to 3000 kN; on-site tests from 1 to 300 kN
Sockets Proof load Not applicable AS 2740 1 to 3000 kN; on-site tests from 1 to 300 kN
Swivels Proof load Not applicable AS 2318 1 to 3000 kN; on-site tests from 1 to 300 kN
Synthetic fibre roundslings Proof load Not applicable

AS 4497

1 to 3000 kN; on-site tests from 1 to 300 kN

Synthetic webbing flat slings Proof load Not applicable

AS 1353.1

1 to 3000 kN; on-site tests from 1 to 300 kN

Wire rope Proof load Not applicable

AS 3569

1 to 3000 kN; on-site tests from 1 to 300 kN

Wire rope slings Proof load Not applicable

AS 1666.1; AS 1666.2; AS 2759; AS 3569

1 to 3000 kN; on-site tests from 1 to 300 kN

Non-destructive testing (NDT) - Electromagnetic testing - Specialised - Magnetic flux leakage (MFL) Wire rope Corrosion; Detection of broken wires; Fretting; Mechanical damage and wear Not applicable
Non-destructive testing (NDT) - Visual testing - During service life Wire rope Detection of broken wires; Fretting; Mechanical damage and wear Visual testing