National Association of Testing Authorities, Australia
Scope of Accreditation
Callidus Process Solutions Pty Ltd
Site
Minara Resources, Murrin Murrin Laboratory – Minara Resources Operations
Accreditation No.
14382
Site No.
14588
Date of Accreditation
26 Jun 2001
Contact
Mr Paul Clarke P: +61 (08) 94415999
Availability
Services available to external clients
Scope of Accreditation
Minara Resources, Murrin Murrin Laboratory – Minara Resources Operations
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of mechanical performance of pressure equipment | Valves | Hydrostatic pressure; Leakage | Not applicable | ANSI FCI 70-2 section 5, API 527 section 4, API 6D section 9, API 576 section 6.2.9.8, API 598 section 5, ASME B16.1 section 9, ASME B 16.34 section 7, JIS B 2032 section 8, ISO 14313 section 11, BS EN 12266-1 Appendix A2, A3, A4, ISA 75:19:01, ISO 5208, MSS SP 61, IEC 60534.4 section 5.4, 5.5 | up to 140 MPa including on-site testing. |
Leakage; Pneumatic pressure | Not applicable | ANSI FCI 70-2 section 5, API 527 section 2 and 5 , API 6D section 9, API 598 section 5, ISO 14313 section 11, API 576 section 6.2.9.8, BS EN 12266-1 Appendix A2, A3, A4, ISO 5208, MSS SP 61, JIS B 2032 section 8, IEC 60534.4 section 5.5, 5.6, ASME B16.34 section 7 | up to 140 MPa including on-site testing. |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
14382
Site No.
14588
Print date
29 Nov 2024
END OF SCOPE