National Association of Testing Authorities, Australia
Scope of Accreditation
Morris McMahon & Co Pty Ltd
Site
Morris McMahon & Co Pty Ltd
Accreditation No.
1747
Site No.
1740
Date of Accreditation
30 Jun 1983
Contact
Mr Andrew Fernandez
P: +61 (02) 95971988
Availability
Services conditionally available to external clients
Scope of Accreditation
Morris McMahon & Co Pty Ltd
ISO/IEC 17025 (2017)
Manufactured Goods
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Performance evaluation of packages and containers | Portable fuel containers | Drop impact resistance | Not applicable |
AS/NZS 2906 Appendix E |
Portable metal fuel containers up to 5L |
External pressure - Vacuum | Not applicable |
AS/NZS 2906 Appendix M |
Portable metal fuel containers up to 5L |
||
Hydrostatic pressure/stability strength | Not applicable |
AS/NZS 2906 Appendix L |
Portable metal fuel containers up to 5L |
||
Handle strength | Not applicable |
AS/NZS 2906 Appendix G, Appendix H |
Portable metal fuel containers up to 5L |
||
Steel drums | Drop impact resistance | Not applicable |
AS 2905-2005 Appendix D |
||
Leakage | Not applicable |
AS 2905-2005 Appendix E |
|||
Handle strength | Not applicable |
AS 2905-2005 Appendix B |
|||
Resistance to internal hydraulic pressure | Not applicable | AS 2905-2005 Appendix F | |||
Tinplate cans for general use | Leakage | Not applicable | AS 2854-2004 Appendix C2, ADG Edition 7.8 clause 6.1.5.4 |
Tin plate drums, pails and cans of 25 L capacity or less |
|
Stacking performance | Compression tester | ADG Edition 7.8 clause 6.1.5.6 |
Tin plate drums, pails and cans of 25 L capacity or less |
||
Lid fit | Not applicable |
AS 2854-2004 Appendix C5 |
Tin plate drums, pails and cans of 25 L capacity or less. |
||
Drop impact resistance | Not applicable |
AS 2854-2004 Appendix C3, ADG Edition 7.8 Clause 6.1.5.3 |
Tin plate drums, pails and cans of 25 L capacity or less |
||
Capacity | Not applicable |
AS 2854-2004 Appendix B |
Tin plate drums, pails and cans of 25 L capacity or less |
||
Resistance to internal hydraulic pressure | Not applicable | ADG Edition 7.8 clause 6.1.5.5 |
Tin plate drums, pails and cans of 25 L capacity or less |
||
Sample collection | Packages and containers | Not applicable | Sample handling |
In-house method QAP001 |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
1747
Site No.
1740
Print date
18 Apr 2024
END OF SCOPE