National Association of Testing Authorities, Australia
Scope of Accreditation
Joy Global Australia Pty Ltd
Site
Moss Vale Site
Accreditation No.
14822
Site No.
14945
Date of Accreditation
22 Aug 2002
Contact
Availability
Type C Inspection Body
Scope of Accreditation
Moss Vale Site
ISO/IEC 17020 (2012)
Infrastructure and Asset Integrity
Service | Product | Determinant | Procedure | Limitations |
---|---|---|---|---|
Industrial machinery - Inspection | Bolting equipment; Gearboxes | Acceptance inspection; Assessment; Manufacturing inspection; Overhaul inspection; Verification | Manufacturers specifications and drawings | Limited to overhaul inspection of power transmission gearboxes, cases, bolting and associated components |
ISO/IEC 17020 (2012)
Manufactured Goods
Service | Product | Determinant | Procedure | Limitations |
---|---|---|---|---|
Explosion-protected electrical equipment - Overhaul and maintenance inspection | Electrical equipment for use in hazardous atmospheres | Pre-overhaul inspection | Covering standards, codes and specifications addressing the service, including AS/NZS 2290.1 | |
Assessment | Covering standards, codes and specifications addressing the service, including AS/NZS 4871.1 App G | Limited to Ex d and Ex i equipment | ||
Electrical equipment for use in hazardous atmospheres; Equipment installed within flameproof (Ex d) enclosures; Ex 'i' intrinsic safety; Flameproof (Ex d) enclosures; Flameproof (Ex d) motors | Overhaul inspection | Covering standards, codes and specifications addressing the service, including AS/NZS 3800 (2020), ANZEx Recognised Service Facility Scheme Rules. | Limited to Group I equipment for use in hazardous areas ANZEx Certificate of Recognition No. ANZEx SF 10.5945 issue 10 Flameproof motors limited to inspection and repair of junction boxes and connection boxes Ex 'i' limited to the overhaul, component repair by replacement, and functional tests of Solenoid Actuator type 09-00343+5100003296, Certificate number IECEx ITA 08.0011X Workshop capability: For Group I equipment 1MVA at 11 kV, 750 kVA at 3300 V, 1MVA at 1000 V | |
Electrical equipment for use in hazardous atmospheres; Equipment installed within flameproof (Ex d) enclosures; Flameproof (Ex d) enclosures | Manufacturing inspection | Covering standards, codes and specifications addressing the service, including AS/NZS 60079.0, AS/NZS 60079.1, AS/NZS 60079.7 and AS/NZS 60079.11 | Limited to Group I equipment for use in hazardous areas Including assessment of newly manufactured and overhauled parts at the Australian Distribution Centre (ADC) at Bld 5 / 415 Pembroke road Minto |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
14822
Site No.
14945
Print date
03 Jan 2025
END OF SCOPE