Caroma Industries Ltd

Site

NSW Research and Development Laboratory

Accreditation No.

5049

Site No.

5042

Date of Accreditation

28 Oct 1993

Address

1 Melito Court
Prestons, NSW 2170
Australia

caroma.com.au

Contact

Dr Steve Cummings P: +61 (02) 88254491

Availability

Services conditionally available to external clients

Scope of Accreditation

NSW Research and Development Laboratory

ISO/IEC 17025 (2017)

Manufactured Goods

Service Product Determinant Technique Procedure Limitations
Products and appliances connected to the water supply - Physical evaluation Baths, sinks and basinsincluding laundry troughs and tubs Dimensions; Drainage; Evaluation of consumer information - Labelling and markings; Evaluation of supports; Rigidity; Strength of assembly Not applicable AS 1172.4 clause 1.5, 1.6, 1.7, 1.8, 1.9, 1.10
AS 1172.5 Clause 1.5.1, 1.5.4, Appendix B (Test 1, Test 2, Test 3, Test 4)
AS 1756 Clauses 1.5, 1.6, 1.7
AS/NZS 1229 Clauses 1.5, 1.6, 1.7, 1.8, Appendix A;
AS/NZS 2023 (1995) Clauses 1.5.3, 1.5.6, Appendix A (Test 1, Test 2, Test 3 and Test 4)
Including laundry troughs and tubs
Flushing valves for water closets and urinals Air separation distance; Discharge volume; Overflow; Spill level; Thrust; Water line Not applicable AS 1172.2 Clauses 1.5.14, 1.5.15, 2.4.3, 2.4.8, Appendices B, G, K, M, N
SS 378 Clause 7.2;
ASME A112.19.2
Sanitary fixtures - Urinals, water closet pan/suites, bidets, douche seats, cisterns and purpose built bathroom modules Flush performance; Splash; Strength of assembly Not applicable

AS 3982 Appendices B, C, D

ASME A112.19.2

Urinals
Air gap; Drainage; Load Not applicable AS 1172.3 Clauses 3.3, 3.4, 3.5,3.6, 4.2, 4.3, Appendix B and C
ASME A112.19.2
Bidets 
Ball appraisal; Capacity; Dimensions; Discharge - Mix media; Discharge - Newspaper; Discharge - Paper; Discharge - Sawdust; Discharge - Solids; Discharge - Toilet Paper; Evaluation of consumer information - Labelling and markings; Flush cycle time; Flush volume; Flushing cleanliness; Granule appraisal; Leakage; Liquids discharge - Contaminant; Liquids discharge - Dye; Liquids discharge - Ink; Load; Overflow; Reduced flush - Paper discharge; Splash; Toilet paper saturation time; Visual examination; Water consumption; Water trap seal; WettingSafety load test Not applicable AS 1172.1 Appendices A, B, C, D, E, F, G, H;
ASME A112.19.2, clause 7.1.5, 7.2, 7.4
ASME A112.19.14
BS EN 997 Annex A;
SS 379 Clauses 3.3, A5.2, A5.3, A5.4, A5.5;
Water Research Evaluation & Testing Centre Ltd
UK: Test code 1412-1, 1511-2, 1512-10, 1512-11, 1512-12, 1611-15, 1611-16, 2111-1, 2212-3, 3212-1, 5011-7, 6001-1
Water closets/pans suites

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.