LightLab International

Site

Optical and Photometric Laboratory

Accreditation No.

2258

Site No.

2251

Date of Accreditation

11 Nov 1987

Address

50 Redcliffe Gardens Drive
Clontarf, QLD 4019
Australia

lsa.com.au

Contact

Mr Toby Southgate P: +61 (07) 32837862

Availability

Services available to external clients

Scope of Accreditation

Optical and Photometric Laboratory

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
Optical metrology - Optical measuring equipment Gloss meters Gloss Direct comparison against a reference standard ISO 2813

Capability

With Calibration and Measurement Capability of -
0.9 GU from 0.0 to 100 GU
Illuminance meters Illuminance Direct comparison against a reference meter

BS 667

 with CCT of source 2856 ±50 K;

 in the range 0.1 to 10 000 lux;

Capability

With Calibration and Measurement Capability of -

Photometers and luxmeters ;
 ± 3 % + 0.1 lux;
Illuminance meters - cosine response;
 0.5 º in angular rotation from -90º to +90º;
 3 % in cosine correction factor;

Luminance meters Luminance Direct comparison against a reference meter

Capability

With Calibration and Measurement Capability of -

3% or 0.1 cd/m2 from 1 cd/m2 to 30 000 cd/m2

UVA meters; Ultraviolet radiometers Irradiance Comparison with a reference meter

Capability

UVA radiometers;

With Calibration and Measurement Capability of -
6% from 30 to 1000 μW/cm² for UVA;

Optical metrology - Optical standards and reference equipment Broadband sources; Diffuse reflectance plates; Discharge sources - Lamps; Filters; Incandescent lamps; LED sources; Solid state lighting (SSL) sources Chromaticity Direct measurement using a reference colorimeter; Direct measurement using a reference spectrophotometer

Capability

With Calibration and Measurement Capability of -

0.003 in CIE 1976 coordinates (x,y) for sources with CCT from 2400 K to 9000 K;
0.002 in CIE 1976 coordinates (u',v') for sources with CCT from 2400 K to 9000K;

Broadband sources; LED sources Correlated colour temperature Measurement using a reference source and reference meter

CIE Publication No. 15.2

Capability

With Calibration and Measurement Capability of -

Broadband sources;

50 K in the correlated colour temperature range from 2 400 K to 5 000 K;

250 K in the correlated colour temperature range from 5 000 K to 9 000 K;

White LED sources;

100 K from 2500 to 6500 K;

Diffuse reflectance plates Luminance Direct measurement using a reference meter

using a 2856 K source in the range 0.01 to 1.00 ;

Capability

with Calibration and Measurement Capability of -

Luminance factor;

0.06 using a 2856 K source in the range 0.01 to 1.00 

Discharge sources - Lamps; Incandescent lamps; LED sources; Solid state lighting (SSL) sources Luminous intensity Direct measurement using a reference meter

Lamps with maximum dimension not exceeding 1 550 mm

 and rated power up to 2 kW

Capability

With Calibration and Measurement Capability of -

Incandescent lamps;
Lamps in the correlated colour temperature range 2 000 K to 3 500 K;
2% from 100 to 2 500 cd;
4% at 2.5 cd decreasing linearly to 2% at 100 cd;
0.1 cd from 0.1 cd to 2.5 cd;

Other sources;
 4% from 2 to 2 500 cd;
 0.1 cd from 0.1 cd to 2.5 cd;

Filters Transmittance Direct measurement using a reference meter; Indirect measurement using a spectrophotometer and software integration

in the range 0.01 to 0.99 using a 2856 K source

Capability

With Calibration and Measurement Capability of -

0.01 in the range 0.01 to 0.99 using a 2856 K source

Incandescent lamps Luminous flux Direct measurement by goniophotometer; Direct measurement by integrating sphere

Lamps with maximum dimension not exceeding 1 550 mm

 and rated power up to 2 kW;

Capability

With Calibration and Measurement Capability of -

4% in the range from 25 to 30 000 lm;
10% decreasing linearly to 4% in the range from 2.5 to 25 lm;

0.1 lm in the range from 0.1 lm to 2.5 lm;

Temperature metrology - Temperature measuring equipmentincluding on site calibrations Digital temperature measuring systems Temperature Measurement against reference standard

Capability

Including on site calibrations

With Calibration and Measurement Capability of -

0.2 °C in the range 0 °C to 120 °C (base metal thermocouple sensors)

0.1 °C in the range 0 °C to 120 °C (metallic resistance thermometer sensors)


 

ISO/IEC 17025 (2017)

Manufactured Goods

Service Product Determinant Technique Procedure Limitations
Evaluation of consumer and industrial lighting, optical systems and eyewear Automotive lights Luminance Direct measurement using a reference meter ADR 48

Registration plates to ADR 48 in the range 0.005 to 40 000 cd/m2

Automotive lights Distribution of luminous intensity; Indicating lights functioning status Direct measurement by goniophotometer

ADR 1/00, 6/00, 45/01, 49/00, 52/00, 53/00, 60/00, 74/00

Luminous intensity from 0.1 to 200 kcd for ;
Reversing lamps;
Turn signal lamps;
Side and position markers and outline lamps;
Stop lamps (including high mounted);
Tail lamps;
Aviation signalling; Maritime signalling Distribution of luminous intensity Direct measurement by goniophotometer

CIE 121

angle;

luminous intensity in the range 0.1 to 200 kcd;

Emergency evacuation lighting and exit luminaires Classification of emergency luminaires; Dimensions; Distribution of luminous intensity; Luminance Direct measurement by goniophotometer; Direct measurement using a reference meter

AS/NZS 2293.3:1995 Appendix C, Clauses 3.3, 3.4, 3.5, 3.6;

AS/NZS 2293.3 Appendix C, Clauses 3.3, 3.4, 3.5, 3.6

angle;

luminous intensity from 0.1 to 200 kcd;

luminance from 0.1 to 10000 cd/m2;

dimensions;

CIE 1931 coordinates (x,y)

Emergency evacuation lighting and exit luminaires; General lighting - Fluorescent lamps; General lighting - Incandescent lamps; General lighting - LED and other solid state lamps; High intensity discharge lamps; LED and other solid state lighting sources; Lighting booths and lighting sources; Lighting for roads and public spaces Endurance Direct measurement using a reference meter; Not applicable

AS/NZS 60598.1 Clause 12; IEC 60598-1 Clause 12;

AS/NZS 60598.2.1; IEC 60598.2.1;

AS/NZS 60598.2.2; IEC 60598.2.2;

AS/NZS 60598.2.3; IEC 60598.2.3;

AS/NZS 60598.2.4; IEC 60598.2.4;

AS/NZS 60598.2.5; IEC 60598.2.5;

AS/NZS 60598.2.7; IEC 60598.2.7;

AS/NZS 60598.2.8; IEC 60598.2.8;

AS/NZS 60598.2.10; IEC 60598.2.10;

AS/NZS 60598.2.13; IEC 60598.2.13;

AS/NZS 60598.2.20; IEC 60598.2.20;

AS/NZS 60598.2.21; IEC 60598.2.21;

AS/NZS 60598.2.22; IEC 60598.2.22;

Endurance and life tests for:
Fixed General Purpose Luminaires;
Recessed Luminaires;
Portable General Purpose Luminaires; 
Portable luminaires for garden use;
Handlamps;
Child appealing luminaires;
Ground recessed luminaires;
Lighting chains;
Rope lights;
Power AC and DC Direct measurement using a reference meter

IES LM-79

ac/dc power;

dc volts;

ac volts;

ac amps;

dc amps;

power factor in the range 0.2 to 1

Lumen depreciation; Lumen maintenance; Temperature - In situ Direct measurement using a reference meter

AS 2293.3 Appendix D1

AS/NZS 3100 and AS 3137 (Temperature of materials and components only)  

IES TM-21; IES LM-84-14 (Annex A)

General lighting - Fluorescent lamps; General lighting - Incandescent lamps; General lighting - LED and other solid state lamps; LED and other solid state lighting sources Chromaticity Measurement using a spectroradiometer and software integration

IES LM-79;

CIE 015

Broadband sources with CCT from 2400 K to 9000 K;

CIE 1976 coordinates (x,y);

CIE 1976 coordinates (u',v');

CIE 1976 (u',v') Colour Differences

Other sources;

CIE 1976 coordinates (x,y);

CIE 1976 coordinates (u',v');

CIE 1976 (u',v') Colour Differences;

Correlated colour temperature Measurement using a spectroradiometer and software integration

AS/NZS 1680.2.5;

IES LM-79;

CIE 15.2

Broadband sources;

correlated colour temperature in the range from 900 K to 5000 K;

White sources;

in the range from 2500 to 6500 K;

Distribution of luminous intensity Not applicable

CIE 121;

IES LM-79

Luminaires for interior lighting with maximum light emitting dimensions not exceeding 1550 mm and rated supply power up to 2 kW;

angle;

relative luminous intensity over the range from 10 to 100000 cd/1000 lamp lm;

luminous intensity from 0.1 to 200 kcd;

light output ratio in the range 1% to 125%;

luminous efficacy in the range from 10 lm/W to 250 lm/W


Cyanosis observation index Measurement using a spectroradiometer and software integration

AS/NZS 1680.2.5;

CIE 15

Broadband LED sources and blackbody sources (2000 K to 9000 K);

Cyanosis observation index in the range 0.5 to 20;

Other sources;

Cyanosis observation index in the range 0.5 to 20;

Melanopic ratio (melanopic factor) Measurement using a spectroradiometer and software integration

Well Building Standard V1;

CIE 15

DIN 5031:100

Melanopic Ratio for Blackbody sources (2000 K to 9000 K) in the range 0.01 to 10;

Melanopic Ratio for Broadband LED sources and other sources in the range 0.01 to 10;

Colour rendering indices Measurement using a spectroradiometer and software integration

AS/NZS 1680.2.5;

IES LM-79;

CIE 13

Colour rendering index of broadband sources in the range 0 to 100;

General lighting - Fluorescent lamps; General lighting - Incandescent lamps; General lighting - LED and other solid state lamps; LED and other solid state lighting sourcesBroadband sources Colour spacial uniformity Indirect measurement using a spectrophotometer and software integration

IES LM-79;

Broadband sources; 
Spectral irradiance Direct measurement using a reference meter

IES LM79

Broadband sources - Relative Spectral Irradiance over the range 380 to 780 nm;
General lighting - Fluorescent lamps; General lighting - Incandescent lamps; LED and other solid state lighting sources Luminous flux Direct measurement by goniophotometer; Direct measurement by integrating sphere; Not applicable

CIE 121;

IES LM-79

Lamps with maximum dimension not exceeding 1550 mm
and rated power up to 2 kW;
Luminous flux in the range from 0.1 lm to 400 klm;
General lighting - LED and other solid state lamps Distribution of luminous intensity; Lamp efficacy; Light output Direct measurement by goniophotometer; Direct measurement by integrating sphere; Direct measurement using a reference meter; Not applicable

IES LM-79

angle;

luminous intensity from 0.1 to 200 kcd;

light output ratio in the range 1% to 125%;

luminous efficacy in the range from 10 lm/W to 250 lm/W

High intensity discharge lamps Distribution of luminous intensity Direct measurement by goniophotometer; Not applicable

CIE 43/121;

IES LM-35; IES LM-79

Luminaires for flood lighting with maximum light emitting dimensions not exceeding 1550 mm and rated supply power up to 2 kW;

angle;

relative luminous intensity over the range from 10 to 100000 cd/1000 lamp lm;

luminous intensity from 0.1 to 200 kcd;

light output ratio in the range 1% to 125%;

luminous efficacy in the range from 10 lm/W to 250 lm/W


Lighting for roads and public spaces Distribution of luminous intensity Direct measurement by goniophotometer; Not applicable

AS/NZS 1158.1; AS/NZS 1158.2; AS/NZS 1158.3;

CIE 121;

IES LM-79

Streetlight luminaires for road lighting with maximum light emitting dimensions not exceeding 1550 mm and rated supply power up to 2 kW;

angle;

relative luminous intensity over the range from 10 to 100000 cd/1000 lamp lm;

luminous intensity from 0.1 to 200 kcd;

light output ratio in the range 1% to 125%;

luminous efficacy in the range from 10 lm/W to 250 lm/W


Illuminance Direct measurement by goniophotometer; Direct measurement using a reference meter

AS/NZS 1158;


in the range 0.1 to 1000 lux

Windows, windscreens and other safety glazing products Luminous transmittance Direct measurement using a reference meter

AS 2080:1995 Appendix E

luminous transmittance in the range 0.01 to 1.00;

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.