ALTRAD APTS Pty Ltd

Site

Perth NDT Laboratory

Accreditation No.

14921

Site No.

22880

Date of Accreditation

24 Jul 2015

Address

39 Success Way
Henderson, WA 6166
Australia

apts.com.au

Contact

Mr Michael Needham P: +61 (08) 94121500

Availability

Services available to external clients

Scope of Accreditation

Perth NDT Laboratory

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Limitations
Non-destructive testing (NDT) - Material properties and internal integrity Welded joints - Aluminium alloys; Welded joints - Clad and overlaid steel; Welded joints - Copper and copper-nickel alloys; Welded joints - Ferritic materials; Welded joints - Stainless steel, austenitic and duplex materials; Welded joints - Titanium and titanium alloys Radiographic detection and characterisation of discontinuities Computed radiography (CR); Digital radiography (DR); Film radiography
Welded joints - Ferritic materials Ultrasonic detection and characterisation of discontinuities A-scan capability
Non-destructive testing (NDT) - Product profile and corrosion mapping Metallic piping; Metallic plate Radiographic determination of wall thickness and material profiling Computed radiography (CR); Digital radiography (DR)
Ultrasonic material thickness - Spot or grid measurements A-scan - Manual
Ultrasonic material profiling and characterisation of material loss A-scan - Manual
Non-destructive testing (NDT) - Surface techniques Metallic surfaces Magnetic particle detection of discontinuities AC magnetic flow
Visual detection of discontinuities (prior to initial service) - Rolled products Visual examination
Visual detection of discontinuities (prior to initial service) - Welded joints Visual examination
Dye penetrant detection of discontinuities Solvent removable; Water washable

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.