Knauf Gypsum Pty Ltd

Site

Product and Systems Development

Accreditation No.

1495

Site No.

1488

Date of Accreditation

23 Dec 1980

Address

22 Kirra Street
Pinkenba, QLD 4008
Australia

knaufapac.com/en_au

Contact

Availability

Services conditionally available to external clients

Scope of Accreditation

Product and Systems Development

ISO/IEC 17025 (2017)

Manufactured Goods

Service Product Determinant Technique Procedure Limitations
Evaluation of fire risk for building materials, components and structures Components for the protection of openings in fire resistant walls and separating elements Fire resistance Furnace AS 1530.4 For the purposes of determining compliance with select requirements of AS 4072.1
Elements of building construction Fire resistance Not applicable AS 1530.4,
BS 476-20,
BS 476-22,
ISO 834-1,
ISO 834-5,
ISO 834-8,
ISO 834-9,
ISO 834-12
AS 1530.4 – Sections 3.0, 4.0, 10. Not including loadbearing walls. Excluding measurements of total heat flux.
Fire resistance tests on horizontal and vertical elements of building constructions which can be accommodated in a furnace with nominal opening dimensions 4 m × 3 m
 
Mechanical performance evaluation of components for building envelopes, framing and interior lining Plasterboard; Wall, floor and ceiling panels Impact resistance; Resistance to static pressure Not applicable

ASTM E72 

ASTM E695

NCC 2022 BCA Test Method S6C10 parts b) and c)
For compliance with BCC 2019:Spec C1.8:5

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.