IRISNDT

Site

Perth Facility

Accreditation No.

15535

Site No.

21324

Date of Accreditation

05 Feb 2013

Address

Unit 4, , 5 Merino Entrance
Cockburn Central, WA 6164
Australia

irisndt.com/au

Contact

Availability

Services available to external clients

Scope of Accreditation

Perth Facility

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Non-destructive testing (NDT) - Electromagnetic testing Metallic surfaces Defect detection and characterisation High frequency eddy current
Non-destructive testing (NDT) - Ultrasonic testing Castings; Forgings; Metallic components; Metallic piping; Metallic plate Material loss characterisation; Profiling A-scan - Manual; C-scan - Mechanised
Metallic piping; Metallic plate Material thickness - Spot/grid only A-scan - Manual; Thickness meter
Rolled or wrought steel products; Welded joints - Ferritic materials Defect detection and characterisation A-scan - Manual
Non-destructive testing (NDT) - Ultrasonic testing - Specialised - Phased array (PAUT) Rolled or wrought steel products; Welded joints - Ferritic materials Defect detection and characterisation Automatic; Manual
Non-destructive testing (NDT) - Ultrasonic testing - Specialised - Time of flight diffraction (ToFD) Rolled or wrought steel products; Welded joints - Ferritic materials Defect detection and characterisation Automatic; Manual
Non-destructive testing (NDT) - Visual testing - During service life Welded joints Defect detection Visual testing Structural welds in mining equipment, cranes and lifting booms, Welds in pressure equipment including Air receivers, Deaerators and Boilers, Welds in pressure piping in mineral processing,and petrochemical applications, Welds in storage tank shells

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.