National Association of Testing Authorities, Australia
Scope of Accreditation
Regional Asset Maintenance Services Pty Ltd
Site
RAM Services – Hyperbaric Division
Accreditation No.
19939
Site No.
23359
Date of Accreditation
01 Aug 2016
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
| Service | Product | Determinant | Technique | Procedure | Limitations |
|---|---|---|---|---|---|
| Evaluation of mechanical performance of pressure equipment | Hose and hose assemblies | Hydrostatic pressure | Not applicable | AS 2683 section 2.1.4, ISO 1402 sections 7 and 8.1 | up to 400000 kPa [4000 bar or approx. 58000 psi] including on-site testing |
| Piping | Hydrostatic pressure | Not applicable | AS 4041 section 6.7, ASME B31.3 Chapter VI section 345.5, ASME B31.3 Chapter IX Part 10 sections K345.5 and K 345.6 | up to 400000 kPa [4000 bar or approx. 58000 psi] including on-site testing | |
| Pneumatic pressure | Not applicable | AS 4041 section 6.8.1, ASME B31.3 Chapter VI section 345.4, ASME B31.3 Chapter IX Part 10 sections K345.4 and K345.6 | up to 200000 kPa [2000 bar or approx. 29000 psi] including on-site testing | ||
| Pressure fittings; Valves | Hydrostatic pressure | Not applicable |
API 527 section 4, API 576 section 6, AS 1271 section 2.6, AS/NZS 3788 section 4.7 |
up to 400000 kPa [4000 bar or approx. 58000 psi] including on-site testing for determination of compliance with API 526 section 9 |
|
| Pneumatic pressure | Not applicable |
API 527 section 2, API 576 section 6, AS 1271 section 3.6, AS/NZS 3788 section 4.7 |
up to 200000 kPa [2000 bar or approx. 29000 psi] including on-site testing for determination of compliance with API 526 section 9 |
||
| Pressure vessels | Pneumatic pressure | Not applicable | AS 1210 section 5.11, AS 2337.1 Appendix C, AS 4037 section 18, ASME BPVC VIII Division 1 section UG-100 | up to 200000 kPa [2000 bar or approx. 29000 psi] including on-site testing | |
| Hydrostatic pressure | Not applicable | AS 1210 section 5.10, AS 4037 section 17, ASME BPVC VIII Division 1 section UG-99 | up to 400000 kPa [4000 bar or approx. 58000 psi] including on-site testing |
The only data displayed is that deemed relevant and necessary for the clear description of the Activities and Services covered by the Scope of Accreditation (SoA).
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
The Product column may also describe an Item or Material.
The Limitations column may also describe the Range.
Accreditation No.
19939
Site No.
23359
Print date
25 Aug 2026