National Association of Testing Authorities, Australia
Scope of Accreditation
Score Australasia Pty Ltd
Site
Score Perth
Accreditation No.
20437
Site No.
22556
Date of Accreditation
23 Jan 2015
Contact
Ms Amira Rizkallah P: +61 (08) 64002500
Availability
Services available to external clients
Scope of Accreditation
Score Perth
ISO/IEC 17025 (2017)
Infrastructure and Asset Integrity
| Service | Product | Determinant | Technique | Procedure | Limitations |
|---|---|---|---|---|---|
| Evaluation of mechanical performance of pressure equipment | Valves | Leakage rate; Pneumatic pressure; Re-seating pressure; Seat leakage; Set pressure | Not applicable | API 6D section 9, API 527 sections 2 and 5, API 598 section 5, ANSI FCI 70-2 section 5, ASME B16-34 section 7 | up to 140 MPa; including on-site tests |
| Hydrostatic pressure; Leakage rate; Re-seating pressure; Seat leakage; Set pressure | Not applicable | API 6D section 9, API 527 section 4, API 598 section 5, ANSI FCI 70-2 section 5, ASME B16-34 section 7 | up to 140 MPa; including on-site tests |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
20437
Site No.
22556
Print date
26 Apr 2026
END OF SCOPE