Tasmanian Water & Sewage Corporation Pty Ltd t/a TasWater - Selfs Point Laboratory

Site

Selfs Point Laboratory

Accreditation No.

19462

Site No.

15678

Date of Accreditation

23 May 2007

Address

Selfs Point WWTP, Selfs Point Road
New Town, TAS 7008
Australia

taswater.com.au

Contact

Ms Rachel Gill P: +61 0499816631

Availability

Services conditionally available to external clients

Scope of Accreditation

Selfs Point Laboratory

ISO/IEC 17025 (2017)

Environment

Service Product Determinant Technique Procedure
Analysis for microorganisms Estuarine waters; Marine waters; Potable waters; Purified and processed waters; Recycled waters; Sewage; Swimming pool and spa waters Plate count Defined substrate technology

APHA 9215E (in-house method TWL3811)

Enterococci Defined substrate technology

in-house method TWL3810

Escherichia coli​​​​; Coliforms Defined substrate technology

AS 4276.21 (in-house method TWL-3809)

Enterococci Membrane filter

AS 4276.9 (in-house method TWL-3804)

Escherichia coli​​​​; Coliforms Membrane filter

AS 4276.5 (in-house method TWL-3813)

Analysis for nutrients Ground waters; Potable waters; Saline waters; Sewage; Trade wastes Nitrogen - Total Kjeldahl (TKN) Calculation

in-house method TWL-3716

Nitrogen - Total oxidised Discrete analyser (DA)

in-house method TWL-3713

Phosphorus - Total Discrete analyser (DA)

in-house method TWL-3714

Phosphorus - Ortho Discrete analyser (DA)

in-house method TWL-3715

Nitrogen - Total Discrete analyser (DA)

in-house method TWL-3712

Ground waters; Potable waters; Sewage; Trade wastes Nitrogen - Ammonia Discrete analyser (DA)

in-house method TWL-3717

Analysis for physical and chemical characteristics Ground waters; Potable waters; Saline waters; Sewage; Trade wastes Fluoride Ion selective electrode (ISE)

in-house method TWL-3706

Chemical oxygen demand (COD) Colourimetry

in-house method TWL-3755

Solids - Suspended Filtration

in-house method TWL-3509

pH Electrometric

in-house method TWL-3707

Solids - Dissolved Calculation

in-house method TWL-3503

Biochemical oxygen demand (BOD) Direct reading instrument

in-house method TWL-1752, TWL-1753

Conductivity Direct reading instrument

in-house method TWL-3503

Oil and grease Infrared (IR)

in-house method TWL-1757

Alkalinity Titration

in-house method TWL-3501

Salinity Calculation

in-house method TWL-3503 (calculation from conductivity measurement)

Turbidity Nephelometry

in-house method TWL-3513

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.