National Association of Testing Authorities, Australia
Scope of Accreditation
Signify Innovations Australia Pty Ltd
Signify Innovations Australia Pty Ltd, Pierlite Australia
Site
Signify Innovation Centre
Accreditation No.
21180
Site No.
25486
Date of Accreditation
22 Nov 2024
Contact
Availability
Services available to external clients
Scope of Accreditation
Signify Innovation Centre
ISO/IEC 17025 (2017)
Manufactured Goods
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Electrical equipment approval and safety evaluation | Enclosures for electrical equipment | Degree of protection - IP rating | Not applicable | AS/NZS 60598.1 IEC 60598-1 Clause 9 excluding 9.2.9; AS/NZS 60598.2.1; AS/NZS 60598.2.2; AS/NZS 60598.2.3; AS/NZS 60598.2.5; AS/NZS 60598.2.22 | For the purposes of compliance with Victorian Energy Efficiency Target Regulations 2018 (VEET) |
Lamps and lampholders (including LED-based lamps); Luminaires | Electrical performance of electrical cables, cords and conductors; Electrical safety; Electrical safety of electrical cables, cords and conductors; Ignition source risk | Adhesion; Ball pressure; Conductor resistance; Current; Dimensional assessment including creepage and clearance; Electrical characteristics; Endurance and resistance to external conditions; Energy measurement; Fire hazard assessment; Function assessment including abnormal operation; Glow wire flammability; High voltage; Insulation and electrical protection measurement; Mechanical assessment; Needle flame; Short circuit capacity; Temperature; Tensile strength; Visual examination | AS/NZS 60598.1 AS/NZS 60598.2.1; AS/NZS 60598.2.2; AS/NZS 60598.2.3; AS/NZS 60598.2.5; AS/NZS 60598.2.22 | For the purposes of compliance with Victorian Energy Efficiency Target Regulations 2018 (VEET). Excluding rough service luminaires. | |
Evaluation of consumer and industrial lighting, optical systems and eyewear | Emergency evacuation lighting and exit luminaires | Chromaticity; Classification of emergency luminaires; Distribution of luminous intensity; Endurance; Illuminance; Impedance; Lamp circuit power (LCP); Lumen maintenance; Power; Power AC and DC; Power factor; Temperature - In situ; Voltage | Calculation; Direct comparison against a reference meter; Direct measurement by goniophotometer; Direct measurement using a reference colorimeter; Direct measurement using a reference meter; Direct measurement using a reference spectrophotometer; Direct measurement using a reference standard | AS/NZS 2293.3 Annex C; AS/NZS 2293.3 Annex D; AS/NZS 60598.1 AS/NZS 60598.2.1; AS/NZS 60598.2.2; AS/NZS 60598.2.3; AS/NZS 60598.2.5; AS/NZS 60598.2.22 IES TM 21 (lumen depreciation method) and IES LM 84 (Annex A) | For the purposes of compliance with Victorian Energy Efficiency Target Regulations 2018 (VEET) |
General lighting - Fluorescent lamps; General lighting - LED and other solid state lamps; LED and other solid state lighting sources | Chromaticity; Colour; Colour rendering indices; Colour spacial uniformity; Correlated colour temperature; Cyanosis observation index; Displacement factor; Distribution of luminous intensity; Endurance; Flicker and time modulated effects; Illuminance; Impedance; Lamp circuit power (LCP); Light output; Lumen depreciation; Lumen maintenance; Luminance; Luminous efficacy; Luminous flux; Maintained luminous efficacy; Median lifetime testing; Melanopic ratio (melanopic factor); Power AC and DC; Power factor; Temperature - In situ; Voltage | Calculation; Calculation from measured luminous flux and power; Direct comparison against a reference meter; Direct measurement by goniophotometer; Direct measurement using a reference meter; Direct measurement using a reference standard; Visual examination | AS/NZS 1680.3; IES LM-79; CIE S025; CIE 15; IES TM 21 (lumen depreciation method) AS/NZS 60598.2.1; AS/NZS 60598.2.2; AS/NZS 60598.2.3; AS/NZS 60598.2.5; AS/NZS 60598.2.22 | For the purposes of compliance with Victorian Energy Efficiency Target Regulations 2018 (VEET); Measurement of luminaires up to 1100 mm maximum dimension; Measurement of Correlated colour temperature and colour rendering indices for near‐white light sources only; Measurement of colour rendering indices Ra and R9 only. |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
21180
Site No.
25486
Print date
06 Dec 2024
END OF SCOPE