Singleton Branch

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Non-destructive testing (NDT) - Magnetic particle testing Metallic surfaces - Magnetic Defect detection and characterisation AC magnetic flow

Non-destructive testing (NDT) - Penetrant testing Metallic surfaces Defect detection and characterisation Solvent removable; Water washable

Non-destructive testing (NDT) - Radiographic testing Wire rope Corrosion; Detection of broken wires; Fretting; Material loss; Mechanical damage and wear Film radiography
Non-destructive testing (NDT) - Ultrasonic testing Castings - Cast irons, steel and alloy steels; Rolled or wrought steel products; Welded joints - Ferritic materials Defect detection and characterisation A-scan - Manual
Metallic piping; Metallic plate Material thickness - Spot/grid only A-scan - Manual
Material loss characterisation; Profiling A-scan - Manual
Non-destructive testing (NDT) - Visual testing - During service life Welded joints Corrosion; Defect detection; Mechanical damage and wear Visual testing Examination for evidence of cracking, mechanical damage, pitting and corrosion on structural welds on baskets and fillet and butt welds on cranes, earth-moving and mining equipment
Non-destructive testing (NDT) - Visual testing - Prior to initial service Welded joints Defect detection Visual testing

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.