Air Liquide Australia Limited

Site

Specialty Gases

Accreditation No.

1508

Site No.

14737

Date of Accreditation

21 Jun 2004

Address

40 Bunnett Street
Sunshine North, VIC 3020
Australia

airliquide.com.au

Contact

Mr Jovan Janackovic P: +61 (03) 92901105

Availability

Services conditionally available to external clients

Scope of Accreditation

ISO 17034 (2016)

Calibration

Service Product Determinant Technique Procedure Limitations
Certified reference gases Reference gases and reference gas mixes Nitrogen Comparison method; Gravimetric method

ISO 6142, ISO 6142-1, ISO 6143

(5 μmol/mol to 100%)

Capability

0.2% relative for concentrations ≥ 10 cmol/mol

0.5% relative for concentrations ≥ 0.1 mmol/mol to 10 cmol/mol

1% relative for concentrations ≥ 10 μmol/mol to 100 μmol/mol

2% relative for concentrations ≤ 10 μmol/mol

Carbon dioxide (CO2) Comparison method; Gravimetric method

ISO 6142, ISO 6142-1, ISO 6143

(1 μmol/mol to 100%)

Capability

0.2% relative for concentrations ≥ 10 cmol/mol

0.5% relative for concentrations ≥ 0.1 mmol/mol to 10 cmol/mol

1% relative for concentrations ≥ 10 μmol/mol to 100 μmol/mol

2% relative for concentrations ≤ 10 μmol/mol

Argon Comparison method; Gravimetric method

ISO 6142, ISO 6142-1, ISO 6143

(5 μmol/mol to 100%)

Capability

0.2% relative for concentrations ≥ 10 cmol/mol

0.5% relative for concentrations ≥ 0.1 mmol/mol to 10 cmol/mol

1% relative for concentrations ≥ 10 μmol/mol to 100 μmol/mol

2% relative for concentrations ≤ 10 μmol/mol

Nitrogen dioxide Comparison method; Gravimetric method

ISO 6142, ISO 6142-1, ISO 6143

(1 μmol/mol to 2000 μmol/mol)

Capability

1% relative for concentrations ≥ 1 mmol/mol 

2% relative for concentrations ≥ 10 μmol/mol to 1 mmol/mol

5% relative for concentrations ≤ 10 μmol/mol

Carbon monoxide Comparison method; Gravimetric method

ISO 6142, ISO 6142-1, ISO 6143

(1 μmol/mol to 100%)

Capability

0.2% relative for concentrations ≥ 10 cmol/mol

0.5% relative for concentrations ≥ 0.1 mmol/mol to 10 cmol/mol

1% relative for concentrations ≥ 10 μmol/mol to 100 μmol/mol

2% relative for concentrations ≤ 10 μmol/mol

Carbonyl sulfide Comparison method; Gravimetric method

ISO 6142, ISO 6142-1, ISO 6143

(0.5 μmol/mol to 1000 μmol/mol)

Capability

1% relative for concentrations ≥ 1 mmol/mol 

2% relative for concentrations ≥ 10 μmol/mol to 1 mmol/mol

5% relative for concentrations ≤ 10 μmol/mol

Nitric oxide Comparison method; Gravimetric method

ISO 6142, ISO 6142-1, ISO 6143

(1 μmol/mol to 2000 μmol/mol)

Capability

1% relative for concentrations ≥ 1 mmol/mol 

2% relative for concentrations ≥ 10 μmol/mol to 1 mmol/mol

5% relative for concentrations ≤ 10 μmol/mol

1-Butylene (1-butene); 1-Hexene; 1-Pentene; 2,2-Dimethylbutane; 2,2-Dimethylpropane (neopentane); 2,3-Dimethylbutane; 2-Methylbutane (isopentane); Benzene; Butane (n-butane); Ethane; Ethene (ethylene); Ethyne (acetylene); Heptane (n-heptane); Hexane (n-hexane); Isobutane; Isobutylene; Methane; Nonane (n-nonane); Octane (n-octane); Pentane (n-pentane); Propane; Propene (propylene); Toluene; cis-2-Butene; trans-2-Butene Comparison method; Gravimetric method

ISO 6142, ISO 6142-1, ISO 6143

(1 μmol/mol to 100%)

Capability

0.2% relative for concentrations ≥ 10 cmol/mol

0.5% relative for concentrations ≥ 0.1 mmol/mol to 10 cmol/mol

1% relative for concentrations ≥ 10 μmol/mol to 100 μmol/mol

2% relative for concentrations ≤ 10 μmol/mol

Neon Comparison method; Gravimetric method

ISO 6142, ISO 6142-1, ISO 6143

(100 μmol/mol to 100%)

Capability

0.2% relative for concentrations ≥ 10 cmol/mol

0.5% relative for concentrations ≥ 0.1 mmol/mol to 10 cmol/mol

1% relative for concentrations ≥ 10 μmol/mol to 100 μmol/mol

2% relative for concentrations ≤ 10 μmol/mol

Sulfur dioxide Comparison method; Gravimetric method

ISO 6142, ISO 6142-1, ISO 6143

(0.5 μmol/mol to 100%)

Capability

1% relative for concentrations ≥ 1 mmol/mol 

2% relative for concentrations ≥ 10 μmol/mol to 1 mmol/mol

5% relative for concentrations ≤ 10 μmol/mol

Helium Comparison method; Gravimetric method

ISO 6142, ISO 6142-1, ISO 6143

(50 μmol/mol to 100%)

Capability

0.2% relative for concentrations ≥ 10 cmol/mol

0.5% relative for concentrations ≥ 0.1 mmol/mol to 10 cmol/mol

1% relative for concentrations ≥ 10 μmol/mol to 100 μmol/mol

2% relative for concentrations ≤ 10 μmol/mol

Oxygen Comparison method; Gravimetric method

ISO 6142, ISO 6142-1, ISO 6143

(1 μmol/mol to 100%)

Capability

0.2% relative for concentrations ≥ 10 cmol/mol

0.5% relative for concentrations ≥ 0.1 mmol/mol to 10 cmol/mol

1% relative for concentrations ≥ 10 μmol/mol to 100 μmol/mol

2% relative for concentrations ≤ 10 μmol/mol

Hydrogen Comparison method; Gravimetric method

ISO 6142, ISO 6142-1, ISO 6143

(50 μmol/mol to 100%)

Capability

0.2% relative for concentrations ≥ 10 cmol/mol

0.5% relative for concentrations ≥ 0.1 mmol/mol to 10 cmol/mol

1% relative for concentrations ≥ 10 μmol/mol to 100 μmol/mol

2% relative for concentrations ≤ 10 μmol/mol

Dinitrogen monoxide (nitrous oxide) Comparison method; Gravimetric method

ISO 6142, ISO 6142-1, ISO 6143

(5 μmol/mol to 100 %)

Capability

1% relative for concentrations ≥ 1 mmol/mol 

2% relative for concentrations ≥ 10 μmol/mol to 1 mmol/mol

5% relative for concentrations ≤ 10 μmol/mol

Hydrogen sulfide Comparison method; Gravimetric method

ISO 6142, ISO 6142-1, ISO 6143

(0.5 μmol/mol to 1000 μmol/mol)

Capability

1% relative for concentrations ≥ 1 mmol/mol 

2% relative for concentrations ≥ 10 μmol/mol to 1 mmol/mol

5% relative for concentrations ≤ 10 μmol/mol

ISO 17034 (2016)

Legal

Service Product Determinant Technique Procedure Limitations
Forensic certified reference materials Ethanol reference standards Ethanol in nitrogen Comparison method; Gravimetric method

ISO 6142, ISO 6142-1, ISO 6143

50 μmol/mol to 500 μmol/mol

Capability

1% relative

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.