Switchmode Power Supplies Pty Ltd

Site

Switchmode Power Supplies

Accreditation No.

16641

Site No.

17961

Date of Accreditation

24 Nov 2009

Address

1/37 Leighton Place
Hornsby , NSW 2077
Australia

switchmode.com.au

Contact

Mr Martin Griffith P: +61 (02) 94760300

Availability

Services available to external clients

Scope of Accreditation

Switchmode Power Supplies

ISO/IEC 17025 (2017)

Calibration

  • The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service Product Determinant Technique Procedure Limitations
DC and low frequency electrical metrology - Electrical measurement and test equipment Ammeters; Digital multimeters (DMM) AC current; DC current Direct measurement against a reference standard

Capability

with Calibration and Measurement Capability of -

D.C. ammeters

0.10% from 0.1 mA to < 1 mA
0.25% from 1 mA to < 10 mA
0.10% from 10 mA to < 1000 mA
0.01% + 0.4 mA from 1 A to < 20 A
0.12% from 20 A to < 100 A
0.22% from 100 A to 400 A

A.C. ammeters

0.16% + 0.04 mA from 10 mA to < 100 mA from 10 Hz to 5 kHz
0.16% + 0.4 mA from 100 mA to < 1000 mA from 10 Hz to 5 kHz
0.19% + 2.2 mA from 1 A to < 10 A from 10 Hz to 5 kHz
0.50% from 10 A to < 20A from 10 Hz to 5 kHz
 0.66% from 20 A to 100 A from 10 Hz to 400 Hz

DC and low frequency electrical metrology - Electrical measurement and test equipment Digital multimeters (DMM); Voltmeters AC voltage; DC voltage Direct measurement against a reference standard

Capability

with Calibration and Measurement Capability of -

D.C. voltmeters

10 µV from 1 mV to <100 mV                
0.011% from 0.1 V to 1000 V

A.C. voltmeters

0.52% from 10 mV to 1000V from 10 Hz to 20 Hz
0.06% + 0.03 mV from 10 mV to < 100 mV from 20 Hz to 20 kHz
0.06% + 0.3 mV from 100 mV to < 1000 mV from 20 Hz to 20 kHz
0.06% + 0.003 V from 1 V to < 10 V from 20 Hz to 20 kHz
0.06% + 0.03 V from 10 V to < 100 V from 20 Hz to 20 kHz
0.06% + 0.225 V from 100 V to 1000 V from 20 Hz to 20 kHz
0.032% at 100 V 45 Hz
0.024% at 135 V 60 Hz
0.024% at 135 V 400 Hz
0.027% at 135 V 5000 Hz
0.023% at 140 V 60 Hz
0.023% at 140 V 1150 Hz
0.015% at 250 V 60 Hz
0.020% at 250 V 1150 Hz
 0.014% at 270 V 400 Hz

DC and low frequency electrical metrology - Electrical measurement and test equipment Power supplies AC current; AC voltage; Active power; DC current; DC voltage Direct measurement against a reference standard

Capability

Power supplies and power conditioners
Power supply equipment and systems
with Calibration and Measurement Capability of -

D.C. voltage
10 µV from 1 mV to <100 mV
0.011% from 0.1 V to 1000 V

A.C. voltage
0.52% from 10 mV to 1000V from 10 Hz to 20 Hz
0.06% + 0.03 mV from 10 mV to <100 mV from 20 Hz to 20 kHz
0.06% + 0.3 mV from 100 mV to < 1000 mV from 20 Hz to 20 kHz
0.06% + 0.003 V from 1 V to < 10 V from 20 Hz to 20 kHz
0.06% + 0.03 V from 10 V to <100 V from 20 Hz to 20 kHz
0.06% + 0.225 V from 100V to 1000 V from 20 Hz to 20 kHz
0.032% at 100 V 45 Hz
0.024% at 135 V 60 Hz
0.024% at 135 V 400 Hz
0.027% at 135 V 5000 Hz
0.023% at 140 V 60 Hz
0.023% at 140 V 1150 Hz
0.015% at 250 V 60 Hz
0.020% at 250 V 1150 Hz
0.014% at 270  V 400 Hz

D.C. current
0.10% from 0.1 mA to < 1 mA
0.25% from 1 mA to <10 mA
0.10% from 10 mA to <1000 mA
0.01% + 0.4 mA from 1 A to <20 A
0.12% from 20 A to <100 A
0.22% from 100 A to 400 A

A.C. current 
0.16% + 0.04 mA from 10 mA to <100 mA from 10 Hz to 5 kHz
0.16% + 0.4 mA from 100 mA to <1000 mA from 10 Hz to 5 kHz
0.19% + 2.2 mA from 1A to <10 A from 10 Hz to 5 kHz
0.50% from 10A to < 20A from 10 Hz to 5 kHz
0.66% from 20 A to 100 A from 10 Hz to 400 Hz

DC power (Up to 50 kW)
0.10% from 1 V to 1000 V and 0.1 A to <1 A
0.05% from 1 V to 1000 V and 1 A to <20 A
0.12% from 1 V to 1000 V and 20 A to <100 A
 0.22% from 1 V to 1000 V and 100 A to 400
 
Active Power (Up to 50 kW, Unity Power Factor)
0.71% from 1 V to 1000 V and 0.1 A to <1 A and 10 Hz to 5 kHz                                                                      
0.60% from 1 V to 1000 V and 1 A to <10 A and 10 Hz to 5 kHz                                                                        
0.67% from 1 V to 1000 V and 10 A to <20 A and 10 Hz to 5 kHz                                                                      
0.80% from 1 V to 1000 V and 20 A to 100 A and 10 Hz to 400 Hz

Frequency                            
0.030% from 10 Hz to 300 kHz              
                             
Time interval                          
0.4 s from 1 s to 10000 s

DC and low frequency electrical metrology - Electrical measurement and test equipment Watt meters Active power Direct measurement against a reference standard

D.C. power

From 1 V to 1000 V and 0.1 A to 400 A (limited to 50 kW)

Active power

From 1 V to 750 V and 0.1 A to 100 A (limited to 50 kW) at Unity power -factor

Capability

with Calibration and Measurement Capability of -

DC power meters (up to 50 kW)
0.10% from 1 V to 1000 V and 0.1 A to < 1 A
0.05% from 1 V to 1000 V and 1 A to < 20 A
0.12% from 1 V to 1000 V and 20 A to < 100 A
0.22% from 1 V to 1000 V and 100 A to 400 A

Active power meters (Up to 50 kW, Unity Power Factor)
0.71% from 1 V to 1000 V and 0.1 A to < 1 A and 10 Hz to 5 kHz
0.60% from 1 V to 1000 V and 1 A to < 10 A and 10 Hz to 5 kHz
0.67% from 1 V to 1000 V and 10 A to < 20 A and 10 Hz to 5 kHz
 0.80% from 1 V to 1000 V and 20 A to 100 A and 10 Hz to 5 kHz

The only data displayed is that deemed relevant and necessary for the clear description of the Activities and Services covered by the Scope of Accreditation (SoA).

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.

The Product column may also describe an Item or Material.

The Limitations column may also describe the Range.