National Association of Testing Authorities, Australia
Scope of Accreditation
Simtars
Site
Training, Testing and Certification Centre
Accreditation No.
2681
Site No.
2672
Date of Accreditation
30 Jun 1989
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Chemical metrology - Gas analysers | Gas analysers | Concentration | Comparison measurement against a certified reference material; Direct measurement by certified reference material | in house method LP0022 | Carbon monoxide : NDIR; 0.0001-10% Carbon monoxide : Electrochemical; 0.0001-1% Carbon dioxide : NDIR; 0.001-100% Methane : NDIR; 0.01-100% Methane : Pellistor; 0.01-5% Methane : Methanometer; 0.01-100% Oxygen : Electrochemical; 0.01-25% Oxygen : Paramagnetic; 0.01-25% Hydrogen Sulphide : Electrochemical; 0.1-20000ppm Sulfur dioxide : Electrochemical; 0.1-20000ppm Sulfur dioxide : NDIR; 0.00001-50% Sulfur dioxide : UV fluorescence; 0.1-50ppm Nitric oxide : Chemiluminescent; 0.1-5000ppm Nitrogen dioxide : Chemiluminescent; 0.1-5000ppm Nitrogen dioxide : Electrochemical; 0.1-10000ppm Oxides of nitrogen : Chemiluminescent; 0.1-10000ppm Ammonia : Electrochemical; 0.0001-1% Propane : Pellistor; 0.01-3% Hexane/Methane/Propane: Pellistor; 0.01-100% LEL Methane : FID; 0.01-100% Methane/Hydrogen : Thermal conductivity; 0.01 - 100% LEL | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with least uncertainty of measurement of 5.0 % relative | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flow metrology - Environmental flow measuring devices and systems | Air sampling pumps and meters | Flow rate | Comparison with a reference meter; Volumetric transfer | EP0143 - Procedure for the Calibration of Secondary Flow Meters | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Calibration of gas flowmeters using atmospheric air as the test medium with a minimum test volume of 100 mLWith a Calibration and Measurement Capability of - Bubble flow meter as reference 2% of reading for flow rates from 0.2 L/min to 5 L/min Mass flow meter as reference (1% of reading + 0.006 L/min) for flow rates from 0.1 L/min to 15 L/min | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flow rate | Comparison with a reference meter | EP0140 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Calibration of air sampling pumps using air at atmospheric conditions with Calibration and Measurement Capability of - Sampling pump flow rate: 1.2% of flow from 1 L/min to 3 L/min Sampling pump timer: (0.05% reading + 0.5 minutes) over a minimum of 2 hours | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature metrology - Verification of controlled enclosures | Baths; Furnaces; Ovens | Spatial uniformity; Temperature; Temporal uniformity | Direct temperature measurement | AS 2853- 1986 | From -40 ºC to 850 ºC | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including on site calibrations. With Calibration and Measurement Capability of - | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Environmental chambers - Humidity | Fluctuation; Gradient; Humidity | By temperature and humidity measurement | AS 60068.3.6; IEC 60068.3.6 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including on site calibrations. With Calibration and Measurement Capability of - | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Environmental chambers - Temperature | Fluctuation; Gradient; Temperature | Direct temperature measurement | AS 60068.3.5, IEC 60068.3.5 | From -40 ºC to 300 ºC | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability Including on site calibrations. With Calibration and Measurement Capability of - |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
2681
Site No.
2672
Print date
12 Dec 2024