Valvology Pty Ltd

Site

Valve and Pressure Testing Laboratory

Accreditation No.

2001

Site No.

1994

Date of Accreditation

21 Apr 2017

Address

95 Great Eastern Highway
Rivervale, WA 6103
Australia

totalvs.com.au

Contact

Mr Corey Clifton P: +61 0437290174

Availability

Services available to external clients

Scope of Accreditation

Valve and Pressure Testing Laboratory

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of mechanical performance of pressure equipment Piping; Pressure fittings; Valves Pneumatic pressure Not applicable API 526 section 9, API 527 Section 2 and 5, API 598 sections 5 and 6. API 6D annex H, ASME BPVC section 7 Up to 70 MPa Including on-site testing
Piping; Valves Hydrostatic pressure Not applicable API 526 Section 9, API 527 Section 4, API 598 sections 5 and 6, API 650 F4.4, F7.3.6, F 7.3.7, API 6D annex H, ASME BPVC section 1 clause PG 73.5, AS 4037 section 17 Up to 172 MPa Including on-site testing
Pressure vessels Hydrostatic pressure Not applicable AS 4037 section 17, AS 1210, AS 4041 section 6.8 Up to 138 MPa Including on-site testing

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.