Callidus Process Solutions Pty Ltd

Site

Valve Testing Laboratory

Accreditation No.

14382

Site No.

14589

Date of Accreditation

22 Feb 2001

Address

20 McCourt Road
Yarrawonga, NT 830
Australia

callidusgroup.com.au

Contact

Mr Nelson Baptista P: +61 (08) 89473008

Availability

Services available to external clients

Scope of Accreditation

Valve Testing Laboratory

ISO/IEC 17025 (2017)

Infrastructure and Asset Integrity

Service Product Determinant Technique Procedure Limitations
Evaluation of mechanical performance of pressure equipment Piping Leakage; Pneumatic pressure Not applicable AS 4041 section 6.8 up to 70 MPa
including on-site testing
Hydrostatic pressure; Leakage Not applicable AS 4041 Appendix U, ASME B31.3 Chapter VI Section 345, ASME B16.1 section 9 up to 70 MPa
including on-site testing
Pressure vessels Hydrostatic pressure Not applicable AS 1210  Section 5.10,  AS 4037 Section 17, ASME Section VIII Division 1 Section UG-99 up to 70 MPa
including on-site testing
Pneumatic pressure Not applicable AS 1210  Section 5.11,  AS 4037 Section 18, ASME Section VIII Division 1 Section UG 100 up to 70 MPa
including on-site testing
Valves Leakage; Pneumatic pressure Not applicable ANSI FCI 70-2 section 5, API 527 section 2 and 5, API 6D section 9, ISO 14313 section 11, API 598 section 5, API 576 section 6.2.9.8, ASME B16.34 section 7, API 2000 section 5.4, BS EN 12266-1 Appendix A2, A3, A4, ISO 5208, MSS SP 61, IEC 60534.4 section 5.5, 5.6, JIS B 2032 section 8 up to 70 MPa
including on-site testing
Hydrostatic pressure; Leakage Not applicable ANSI FCI 70-2 section 5, API 527 section 4, API 6D section 9, ISO14313 section 11, API 598 section 5, API 576 section 6.2.9.8, ASME B16.34 section 7, JIS B 2032 section 8, BS EN 12266-1 Appendix A2, A3, A4, ISA 75:19:01, ISO 5208, MSS SP 61, IEC 60534.4 section 5.4, 5.5 up to 70 MPa
including on-site testing

The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.

Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.