National Association of Testing Authorities, Australia
Scope of Accreditation
Verico Asset Integrity Services
Site
Verico Asset Integrity Services
Accreditation No.
4669
Site No.
4662
Date of Accreditation
21 Dec 1996
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Environment
Service | Product | Determinant | Technique | Procedure |
---|---|---|---|---|
Analysis for industrial chemicals | Air - Ambient | Nitrogen - Oxides (NOx) | Chemiluminescence |
AS 3580.5.1 in-house method WFICE 111 |
Sulfur dioxide | Direct reading instrument |
AS 3580.4.1 in-house method WFICE 110 |
||
Analysis for physical and chemical characteristics | Air - Ambient | Particulate matter - PM10 | Tapered element oscillating microbalance (TEOM) |
AS/NZS 3580.9.8 in-house method WFICE 124 |
Particulate matter - PM10 | High volume gravimetric |
AS/NZS 3580.9.6 in-house method WFICE 107 |
||
Particulate matter - PM2.5 | Beta attenuation monitors |
AS 3580.9.12 in-house method 129 |
||
Particulate matter - PM10 | Beta attenuation monitors |
AS 3580.9.11 in-house method 129 |
||
Counting of asbestos, mineral fibres (including synthetic) and organic fibres | Air | Volume measurement | Sampling flow rate and duration measurement | National Occupational Health and Safety Commission Guidance Note on the Membrane Filter Method for the Estimation of Airborne Asbestos Fibres NOHSC:3003 and in-house method WFICE 401 |
Membrane filters | Respirable asbestos fibres | Phase contrast microscopy | National Occupational Health and Safety Commission Guidance Note on the Membrane Filter Method for the Estimation of Airborne Asbestos Fibres NOHSC:3003 and in-house method WFICE 401 | |
Meteorological monitoring | Atmosphere | Wind direction | Ultrasonic anemometer |
AS/NZS 3580.14; USEPA 450/4-87-013 in-house method WFICE 209 |
Relative humidity (RH) | Hygrometer |
USEPA 450/4-87-013 in-house method WFICE 208 |
||
Wind speed - Horizontal | Ultrasonic anemometer |
AS/NZS 3580.14; USEPA 450/4-87-013 in-house method WFICE 209 |
||
Wind speed - Horizontal | Rotating anemometer |
AS/NZS 3580.14 USEPA 450/4-87-013 in-house method WFICE 201 |
||
Temperature | Temperature probe |
USEPA 450/4-87-013 in-house method WFICE 206 |
||
Radiation - Global | Pyranometer |
USEPA 450/4-87-013 in-house method WFICE 207 |
||
Radiation - Net | Pyranometer |
USEPA 450/4-87-013 in-house method WFICE 203 |
||
Wind direction | Rotating anemometer |
AS/NZS 3580.14 USEPA 450/4-87-013 in-house method WFICE 201 |
||
Rainfall | Rainfall gauge |
USEPA 450/4-87-013 in-house method WFICE 205 |
||
Sample collection | Air - Ambient | Not applicable | Continuous flow analyser (CFA); Filter paper - Manual double |
AS 3580.4.1; AS 3580.5.1; AS/NZS 3580.9.3; AS 3580.9.6; AS 3580.9.8; AS 3580.9.11; AS 3580.9.12; AS/NZS 3580.12.1; AS/NZS 3580.13.2 in-house methods WFICE 103; WFICE 105; WFICE 107; WFICE 110; WFICE 111; WFICE 124; WFICE 129; WFICE 130 |
ISO/IEC 17025 (2017)
Materials
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Analysis of lubricants, oils and related products | Electrical insulating oils and compounds | Interfacial tension | Platinum ring |
in-house method ACM 123 |
|
Acidity - Total | Titration |
in-house method ACM 122 |
|||
2-Acetylfuran; 2-Furaldehyde; 2-Furfalalcohol; 5-Hydroxymethyl-2-furaldehyde; 5-Methyl-2-furaldehyde | HPLC |
in-house method ACM 126 |
|||
Aroclor 1242; Aroclor 1254; Aroclor 1260; Polychlorinated biphenyls (PCBs) | Gas chromatography (GC) |
in-house method ACM 127 |
|||
Dielectric loss tangent; Resistivity of transformer insulating oils | Direct reading instrument |
in-house method ACM 125 |
|||
Dissolved gas | Gas chromatography (GC) |
in-house method ACM 120 |
|||
Electric strength | Direct reading instrument |
in-house method ACM 124 |
|||
Water content | Karl-Fischer titration |
in-house method ACM 121 |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
4669
Site No.
4662
Print date