National Association of Testing Authorities, Australia
Scope of Accreditation
Warringtonfire Australia Pty Ltd
Site
Warringtonfire Australia Pty Ltd
Accreditation No.
3277
Site No.
3270
Date of Accreditation
07 Nov 1991
Contact
Availability
Services available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Manufactured Goods
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of fire risk (excluding electrical products) and fire mitigation performance | Building materials | Fire resistance | Not applicable |
AS/NZS 3837 ISO 5660-1 ASTM E1354 |
|
Full-scale room fire appraisal for surface products | Not applicable |
ISO 9705 and AS ISO 9705 ; NFPA 274 ; |
|||
Building materials; Elements of building construction | Thermal properties | Not applicable |
ASTM D5630 - 2013 ISO 1716 |
Not applicable | |
Flammability | Not applicable |
AS 1530.2 |
|||
Flame propagation | Not applicable |
AS 1530.1, AS 5113; ASTM E 2652; BS 8414-1, BS 8414-2; IMO FTPC Part 1; ISO 1182, EN ISO 1182, ISO 13785-1, ISO 13785-2 |
|||
Cable feeders | Fire resistance | Not applicable | AS 3013 | ||
Components for the protection of openings in fire resistant walls and separating elements | Fire resistance | Not applicable |
AS 4072.1-1992; ASTM E814; UL 1479, excluding clause 6A, UL 2079; EN 1366-3, EN 1366-4, EN 1366-7; ASTM E1966; IMO Resolution MSC.307 (88) Part 3 |
||
Fire resistance | Not applicable |
FSB/PSB/001/00; EN 1366-5 |
|||
Elements of building construction | Fire resistance | Not applicable |
AS 1530.4, AS 1530.4-2005 and AS 1530.4-1997; |
Fire resistance tests on elements of building constructions which can be accommodated |
|
Fire resistance | Not applicable |
ASTM E119; UL 263; NFPA 251, NFPA 288; EN 1364-1, EN 1364-3, EN 1365-1, EN 1365-5 IMO Resolution MSC.307 (88) Part 3, Part 4 and Part 11 |
|||
Simulated bushfire attack | Large flaming sources; Small flaming sources | AS 1530.8.1, AS 1530.8.2 | |||
Fire resistance | Not applicable |
UL 555, Section 10 only ISO 10294.1, ISO 10294.5, excluding clause 4.24 EN 1366.2 SS 333 IMO Resolution MSC.307 (88) Part 3 |
|||
Factory made air ducts and air connectors | Fire resistance | Not applicable |
AS/NZS 1530.7, AS/NZS 1530.7-1998, AS 1682.1 (Section 3 only), AS 1682.1-1990 (Section 5 only), AS 4429, Sections 5 and 6 only; EN 1634-3; UL 555S; BS 7346.3, BS 476, Section 31.1, BS 7346.1, Appendix B only, BS 7346.2; EN 12101.3 ISO 5925.1 UL 1784 |
||
Fire sprinkler heads | Functional and compatibility assessment; Leakage | Not applicable |
in-house method NA18 |
||
Windows, doors, shutters and blinds | Fire resistance | Not applicable |
AS 1530.4 section 7 and 8 AS 1905.1-1997; NFPA 252, NFPA 257; ASTM 2074; UL 9, UL 10B, UL 10C; EN 1634-1; SS 332, SS 489; IMO Resolution MSC.307 (88) Part 3, Part 4 and Part 11 (Doors only) |
||
Mechanical performance evaluation of components for building envelopes, framing and interior lining | Door, window and skylight assemblies | Endurance; Mains power failure of powered doors | Not applicable |
AS 5007 clauses 4.4.1 and 4.4.2 only (Cold, dry heat and ambient tests) |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.
Accreditation No.
3277
Site No.
3270
Print date