National Association of Testing Authorities, Australia
Scope of Accreditation
SA Pathology
Site
Calibration and Testing Laboratory
Accreditation No.
3562
Site No.
3555
Date of Accreditation
07 Aug 1992
Contact
Availability
Services conditionally available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Calibration
- The uncertainty of measurement is reported as an expanded uncertainty having a level of confidence of 95% unless stated otherwise
Service | Product | Determinant | Technique | Procedure | Limitations | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature metrology - Ancillary temperature measuring equipment | Multi-channel thermocouple data recorders | Resistance to temperature conversion | Direct measurement by electrical input |
By the methods of - AS 3864, PRC-CEN-23 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 0.5 ºC from -80 ºC to 200 ºC |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature metrology - Temperature measuring equipment | Digital temperature measuring systems; Temperature loggers - Single and multi-channel | Temperature | Comparison with a reference standard |
by the methods of - PRC-CEN-22; PRC-CEN-23; |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 0.3 °C from -196 °C to - 80 °C0.3 °C from above- 80 °C to - 30 °C 0.5 ºC from -80 ºC to 200 ºC for recorders and digital inductors only (including on site) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature metrology - Verification of controlled enclosures | Autoclaves and sterilising ovens | Temporal uniformity | Direct temperature measurement |
By the methods of - AS/NZS 4187:2014 Section 7.4, PRC-CEN-6 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement capability of - 0.5 ºC from 23ºC to 180 ºC |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Baths | Temperature; Temporal uniformity | Direct temperature measurement |
Calibration of baths By the methods of - AS 2853, PRC-CEN-24 In-house calibration of baths By the methods of - PRC-CEN-21 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - Calibration of baths 0.5 ºC from -80ºC to 200ºC In-house calibration of baths 0.15 ºC from -80ºC to 200ºC |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Environmental chambers - Temperature; Ovens | Spatial uniformity; Temperature | Direct temperature measurement |
By the methods of - AS 2853, PRC-CEN-24, PRC-CEN-4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 0.5 ºC from 0 ºC to 100 ºC 1 ºC above 100 ºC to 200 ºC |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Freezers | Temperature | Direct temperature measurement |
By the methods of - AS 2853, PRC-CEN-4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 0.5 ºC from -80ºC to 0ºC |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Incubators | Spatial uniformity; Temperature | Direct temperature measurement |
By the methods of - AS 2853, PRC-CEN-24 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 0.5 ºC from 23ºC to 100ºC |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Medical refrigeration equipment | Temperature; Temporal uniformity | Direct temperature measurement |
By the methods of - AS 3864.2, PRC-CEN-4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 0.5 ºC from -80ºC to 100ºC |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Volume and density - Laboratory volumetric glassware and measures | Piston operated volumetric apparatus (POVA) | Volume | Gravimetric |
ISO 8655-6 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Capability with Calibration and Measurement Capability of - 0.03 μL from 0.4 μL to 4 μL |
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.