National Association of Testing Authorities, Australia
Scope of Accreditation
CSIRO
Site
CSIRO-Land and Water
Accreditation No.
1400
Site No.
1393
Date of Accreditation
22 Aug 1979
Address
c/- Charles Sturt University, Peter Till Laboratories BD666, Lvl 2, Bromfield Court
Thurgoona, NSW 2640
Australia
Contact
Availability
Services conditionally available to external clients
Scope of Accreditation
ISO/IEC 17025 (2017)
Environment
Service | Product | Determinant | Technique | Procedure |
---|---|---|---|---|
Analysis for nutrients | Irrigation and stock waters; Treated effluent | Phosphorus - Soluble reactive | Flow injection analyser (FIA) | in-house ESAL 05B |
Phosphorus - Total | Flow injection analyser (FIA) | in-house ESAL 06 | ||
Nitrogen - Total | Flow injection analyser (FIA) | in-house ESAL 07 | ||
Nitrogen - Ammonia | Flow injection analyser (FIA) | in-house ESAL 02B | ||
Nitrate; Nitrite | Flow injection analyser (FIA) | in-house ESAL 03B | ||
Analysis for physical and chemical characteristics | Irrigation and stock waters; Treated effluent | Carbon - Total organic (TOC); Dissolved organic carbon (DOC); Organic carbon - Dissolved non-purgeable | Nondispersive infrared (NDIR) | in-house ESAL 23 |
Solids - Dissolved; Solids - Suspended | Gravimetric | in-house ESAL 11 | ||
Electrical conductivity | Electrometric | in-house ESAL 09 | ||
Biochemical oxygen demand (BOD) | Ion selective electrode (ISE) | in-house APHA 5210B | ||
Chemical oxygen demand (COD) | UV-vis spectrophotometry | in-house ESAL 16 | ||
Chloride | Flow injection analyser (FIA) | in-house ESAL 15 | ||
Turbidity | Turbidometry | in-house ESAL 10 | ||
pH | Direct reading instrument | in-house ESAL 21 |
ISO/IEC 17025 (2017)
Food and Beverage
Service | Product | Determinant | Technique | Procedure |
---|---|---|---|---|
Analysis of physical and nutritional characteristics | Waters for potable and domestic purposes | Chemical oxygen demand (COD) | UV-vis spectrophotometry | in-house ESAL 16 |
Solids - Dissolved; Solids - Suspended | Gravimetric | in-house ESAL 11 | ||
Carbon - Total organic (TOC); Dissolved organic carbon (DOC); Organic carbon - Dissolved non-purgeable | Nondispersive infrared (NDIR) | in-hosue ESAL 23 | ||
Chloride | Flow injection analyser (FIA) | in-house ESAL 15 | ||
Electrical conductivity | Electrometric | in-house ESAL 09 | ||
Nitrogen - Ammonia | Flow injection analyser (FIA) | in-house ESAL 02B | ||
Nitrate; Nitrite | Flow injection analyser (FIA) | in-house ESAL 03B | ||
Nitrogen - Total | Flow injection analyser (FIA) | in-house ESAL 07 | ||
pH | Direct reading instrument | in-house ESAL 21 | ||
Phosphorus - Soluble reactive | Flow injection analyser (FIA) | in-house ESAL 05B | ||
Turbidity | Turbidometry | in-house ESAL 10 | ||
Phosphorus - Total | Flow injection analyser (FIA) | in-house ESAL 06 |