Infrastructure and Asset Integrity
Service | Product | Determinant | Technique | Procedure | Limitations |
---|---|---|---|---|---|
Evaluation of air control equipment | Air filters | Efficiency - Test dust No.1 | Photometric | AS 1324.2 Section 4 | |
Mass stabilisation | Gravimetric | AS 1324.2 Section 3 | |||
Gravimetric - Test dust No.4 | Gravimetric | AS 1324.2 Section 5 | |||
Initial resistance | Pressure differential | AS1324.2 Section 2 | |||
Air filters; Gas filters | Integrity of HEPA filter installations | Cold DOP | AS 1807.6 for compliance with AS 4260 Section 5.2 - Integrity testing of HEPA filters | Procedures in factory only. | |
Biological safety cabinets | Integrity of HEPA filter installations | Cold DOP | AS 1807.6, (2000), AS 1807.7, AS 1807 clause 4.4, NSF ANSI 49 N5.5 | for compliance with AS 2252.1, AS 2252.2, NSF ANSI 49 | |
Gas tightness | Not applicable | AS 1807.25 (2004), AS 1807 clause 4.11 | for compliance with AS 2252.2 | ||
Illuminance | Not applicable | AS 1807.15 (2000), AS 1807 clause 4.5, NSF ANSI 49 N5.9 | for compliance with AS 2252.1, AS 2252.2, NSF ANSI 49 | ||
Ultraviolet intensity | Not applicable | AS 1807.23 (2000), AS 1807 clause 4.10 | for compliance with AS 2252.2 | ||
Air velocity and uniformity of air velocity | Not applicable | AS 1807.1 (2000), AS 1807 clause 4.1, NSF ANSI 49 N5.2 | for compliance with AS 2252.1, AS 2252.2, NSF ANSI 49 | ||
Inward air velocity | Not applicable | AS 1807.21 (2000) AS 1807 clause 4.8, NSF ANSI 49 N5.3 | for compliance with AS 2252.1, AS 2252.2, NSF ANSI 49 | ||
Work zone integrity | Cold DOP | AS 1807.5 (2000), AS 1807 clause 4.3 | for compliance with AS 2252.2 | ||
Air barrier containment | Cold DOP; Potassium iodide (KI) discus | AS 1807.22 (2000), AS 1807.26 (2004), AS 1807 clause 4.9, 4.12 | for compliance with AS 2252.2 | ||
Sound level | Not applicable | AS 1807.20 (2000), AS 1807 clause 4.7, NSF ANSI 49 N5.11 | for compliance with AS 2252.1, AS 2252.2, NSF ANSI 49 | ||
Clean rooms, pharmaceutical isolators and work stations | Recovery times | Not applicable | AS 1807.24 (2000), AS ISO 14644.3 Method B4 | for compliance with AS 2252.6 (Clean Workstation), AS ISO 14644.3 (Clean Room) | |
Air pressure | Not applicable | AS 1807.10, AS ISO 14644.3 Method B1 | for compliance with AS 2252.6 (Clean Workstation), AS ISO 14644.3 (Clean Room), AS 4273 | ||
Particle count in work zone | Automatic particle counter | AS 1807.8 (2000), AS ISO 14644.1 | for compliance with AS 2252.6 (Clean Workstation), AS ISO 14644.3 (Clean Room), AS 4273 | ||
Sound level | Not applicable | AS 1807.16, AS 1807.20 (2000), AS 1807 Clause 4.7 | for compliance with AS 2252.6 (Clean Workstation), AS ISO 14644.3 (Clean Room) | ||
Illuminance | Not applicable | AS 1807.15 (2000), AS 1807 clause 4.5 | for compliance with AS 2252.6 (Clean Workstation), AS ISO 14644.3 (Clean Room), AS 4273 | ||
Air velocity and uniformity of air velocity | Not applicable | AS 1807.1 (2000), AS 1807.3 (2000), AS 1807 clause 4.1, AS ISO 14644.3 Method B2 | for compliance with AS 2252.6 (Clean Workstation), AS ISO 14644.3 (Clean Room), AS 4273 | ||
Integrity of HEPA filter installations | Cold DOP | AS 1807.6, (2000), AS 1807.7, AS 1807 clause 4.4, AS ISO 14644.3 Method B7 | for compliance with AS 2252.6 (Clean Workstation), AS ISO 14644.3 (Clean Room), AS 4273 | ||
Work zone integrity | Cold DOP | AS 1807.5 (2000), AS 1807 clause 4.3 | for compliance with AS 2252.6 (Clean Workstation), AS ISO 14644.3 (Clean Room), AS 4273 | ||
Cytotoxic drug safety cabinets | Air velocity and uniformity of air velocity | Not applicable | AS 1807.1 (2000), AS 1807 clause 4.1 | for compliance with AS 2252.5 | |
Illuminance | Not applicable | AS 1807.15 (2000), AS 1807 clause 4.5 | for compliance with AS 2252.5 | ||
Ultraviolet intensity | Not applicable | AS 1807.23 (2000), AS 1807 clause 4.10 | for compliance with AS 2252.5 | ||
Sound level | Not applicable | AS 1807.20 (2000), AS 1807 clause 4.7 | for compliance with AS 2252.5 | ||
Work zone integrity | Cold DOP | AS 1807.5 (2000), AS 1807 clause 4.3 | for compliance with AS 2252.5 | ||
Particle count in work zone | Automatic particle counter | AS 1807.8 (2000), AS ISO 14644.1 | for compliance with AS 2252.5 | ||
Integrity of HEPA filter installations | Cold DOP | AS 1807.6, (2000), AS 1807.7, AS 1807 clause 4.4 | for compliance with AS 2252.5 | ||
Fume cupboards and recirculating fume cabinets | Extraction performance | Face velocity | AS/NZS 2243.8 Appendix B; AS/NZS 2243.9 Appendix B | ||
Extraction performance | Smoke visualisation | AS/NZS 2243.8 Appendix A, AS/NZS 2243.9 Appendix A |